Cargando…
Plasma Septin9 versus Fecal Immunochemical Testing for Colorectal Cancer Screening: A Prospective Multicenter Study
BACKGROUND: Screening improves outcomes related to colorectal cancer (CRC); however, suboptimal participation for available screening tests limits the full benefits of screening. Non-invasive screening using a blood based assay may potentially help reach the unscreened population. OBJECTIVE: To comp...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4046970/ https://www.ncbi.nlm.nih.gov/pubmed/24901436 http://dx.doi.org/10.1371/journal.pone.0098238 |
Sumario: | BACKGROUND: Screening improves outcomes related to colorectal cancer (CRC); however, suboptimal participation for available screening tests limits the full benefits of screening. Non-invasive screening using a blood based assay may potentially help reach the unscreened population. OBJECTIVE: To compare the performance of a new Septin9 DNA methylation based blood test with a fecal immunochemical test (FIT) for CRC screening. Design: In this trial, fecal and blood samples were obtained from enrolled patients. To compare test sensitivity for CRC, patients with screening identified colorectal cancer (n = 102) were enrolled and provided samples prior to surgery. To compare test specificity patients were enrolled prospectively (n = 199) and provided samples prior to bowel preparation for screening colonoscopy. MEASUREMENTS: Plasma and fecal samples were analyzed using the Epi proColon and OC Fit-Check tests respectively. RESULTS: For all samples, sensitivity for CRC detection was 73.3% (95% CI 63.9–80.9%) and 68.0% (95% CI 58.2–76.5%) for Septin9 and FIT, respectively. Specificity of the Epi proColon test was 81.5% (95% CI 75.5–86.3%) compared with 97.4% (95% CI 94.1–98.9%) for FIT. For paired samples, the sensitivity of the Epi proColon test (72.2% –95% CI 62.5–80.1%) was shown to be statistically non-inferior to FIT (68.0%–95% CI 58.2–76.5%). When test results for Epi proColon and FIT were combined, CRC detection was 88.7% at a specificity of 78.8%. CONCLUSIONS: At a sensitivity of 72%, the Epi proColon test is non- inferior to FIT for CRC detection, although at a lower specificity. With negative predictive values of 99.8%, both methods are identical in confirming the absence of CRC. TRIAL REGISTRATION: ClinicalTrials.gov NCT01580540 |
---|