Cargando…

Bone properties of the humeral head and resistance to screw cutout

Surgical treatment of fractures involving the proximal humeral head is hampered by complications. Screw cutout is the major pitfall seen in connection with rigid plating. We have exploited a bony explanation for this phenomenon. MATERIALS AND METHODS: We examined the convex surface of the humeral he...

Descripción completa

Detalles Bibliográficos
Autores principales: Frich, Lars Henrik, Jensen, Niels Christian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4049036/
https://www.ncbi.nlm.nih.gov/pubmed/24926160
http://dx.doi.org/10.4103/0973-6042.131851
_version_ 1782480584363212800
author Frich, Lars Henrik
Jensen, Niels Christian
author_facet Frich, Lars Henrik
Jensen, Niels Christian
author_sort Frich, Lars Henrik
collection PubMed
description Surgical treatment of fractures involving the proximal humeral head is hampered by complications. Screw cutout is the major pitfall seen in connection with rigid plating. We have exploited a bony explanation for this phenomenon. MATERIALS AND METHODS: We examined the convex surface of the humeral head looking at the density and the topographical strength of the subchondral bone using mechanical testing of bone cylinders harvested from the humeral head. We also studied the osseous architecture of the subchondral bone and thickness of the boneplate of the humeral head using a 3-dimensional serial sectioning technique. RESULTS: The bone strength and bone density correlated well and revealed large regional variations across the humeral head. Bone strength and stiffness of the trabecular bone came to a maximum in the most medial anterior and central parts of the humeral head, where strong textural anisotropy was also found. We found in particular a lower bone strength and density in the posterior and inferior regions of the humeral head. A rapid decline in bone strength within a few mm below a relatively thin subchondral plate was also reported. CLINICAL RELEVANCE: We have in this paper explored some of the most important factors connected with screw stability at the cancellous bone level. We discovered large variations in bone density and bone strength across the joint surface rendering certain areas of the humeral head less suitable for screw placement. The use of rigid plate constructs with divergent screw directions will predictably place screws in areas of the humeral head comprising low density and low strength cancellous bone. New concepts of plates and plating techniques for the surgical treatment of complex fractures of the proximal humerus should take bone distribution, strength, and architecture into account.
format Online
Article
Text
id pubmed-4049036
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-40490362014-06-12 Bone properties of the humeral head and resistance to screw cutout Frich, Lars Henrik Jensen, Niels Christian Int J Shoulder Surg Original Article Surgical treatment of fractures involving the proximal humeral head is hampered by complications. Screw cutout is the major pitfall seen in connection with rigid plating. We have exploited a bony explanation for this phenomenon. MATERIALS AND METHODS: We examined the convex surface of the humeral head looking at the density and the topographical strength of the subchondral bone using mechanical testing of bone cylinders harvested from the humeral head. We also studied the osseous architecture of the subchondral bone and thickness of the boneplate of the humeral head using a 3-dimensional serial sectioning technique. RESULTS: The bone strength and bone density correlated well and revealed large regional variations across the humeral head. Bone strength and stiffness of the trabecular bone came to a maximum in the most medial anterior and central parts of the humeral head, where strong textural anisotropy was also found. We found in particular a lower bone strength and density in the posterior and inferior regions of the humeral head. A rapid decline in bone strength within a few mm below a relatively thin subchondral plate was also reported. CLINICAL RELEVANCE: We have in this paper explored some of the most important factors connected with screw stability at the cancellous bone level. We discovered large variations in bone density and bone strength across the joint surface rendering certain areas of the humeral head less suitable for screw placement. The use of rigid plate constructs with divergent screw directions will predictably place screws in areas of the humeral head comprising low density and low strength cancellous bone. New concepts of plates and plating techniques for the surgical treatment of complex fractures of the proximal humerus should take bone distribution, strength, and architecture into account. Medknow Publications & Media Pvt Ltd 2014 /pmc/articles/PMC4049036/ /pubmed/24926160 http://dx.doi.org/10.4103/0973-6042.131851 Text en Copyright: © International Journal of Shoulder Surgery http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Frich, Lars Henrik
Jensen, Niels Christian
Bone properties of the humeral head and resistance to screw cutout
title Bone properties of the humeral head and resistance to screw cutout
title_full Bone properties of the humeral head and resistance to screw cutout
title_fullStr Bone properties of the humeral head and resistance to screw cutout
title_full_unstemmed Bone properties of the humeral head and resistance to screw cutout
title_short Bone properties of the humeral head and resistance to screw cutout
title_sort bone properties of the humeral head and resistance to screw cutout
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4049036/
https://www.ncbi.nlm.nih.gov/pubmed/24926160
http://dx.doi.org/10.4103/0973-6042.131851
work_keys_str_mv AT frichlarshenrik bonepropertiesofthehumeralheadandresistancetoscrewcutout
AT jensennielschristian bonepropertiesofthehumeralheadandresistancetoscrewcutout