Cargando…
Enhanced antitumor effects of low-frequency ultrasound and microbubbles in combination with simvastatin by downregulating caveolin-1 in prostatic DU145 cells
Advanced prostate cancer is difficult to treat due to androgen resistance, its deep location and blood tumor barriers. Low-frequency ultrasound (LFU) has potential clinical applications in the treatment of prostate cancer due to its strong penetrability and high sensitivity towards tumor cells. Simv...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
D.A. Spandidos
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4049715/ https://www.ncbi.nlm.nih.gov/pubmed/24932304 http://dx.doi.org/10.3892/ol.2014.2005 |
_version_ | 1782319856652124160 |
---|---|
author | XU, WEI-PING SHEN, E. BAI, WEN-KUN WANG, YU HU, BING |
author_facet | XU, WEI-PING SHEN, E. BAI, WEN-KUN WANG, YU HU, BING |
author_sort | XU, WEI-PING |
collection | PubMed |
description | Advanced prostate cancer is difficult to treat due to androgen resistance, its deep location and blood tumor barriers. Low-frequency ultrasound (LFU) has potential clinical applications in the treatment of prostate cancer due to its strong penetrability and high sensitivity towards tumor cells. Simvastatin has often been administered as a preventive agent in prostate tumors. The aim of the present study was to investigate the enhanced effects of LFU and microbubbles in combination with simvastatin, in inhibiting cell viability and promoting apoptosis of androgen-independent prostatic DU145 cells. Cultured DU145 cells were divided into six groups based on the combination of treatments as follows: Control, LFU, LFU and microbubbles (LFUM), simvastatin, LFU and simvastatin, LFUM and simvastatin. The cells were treated by LFU (80 kHz) continuously for 30 sec with an ultrasound intensity of 0.45 W/cm(2) and a microbubble density of 20%. Simvastatin was added 30 h prior to the ultrasound exposure. The results indicated that cell viability was marginally reduced in the LFU and simvastatin alone treatment groups compared with the control 24 h following ultrasound exposure. The combination of LFU, with microbubbles or simvastatin, potentiated the growth inhibition; the greatest inhibition was observed in the cells that were subject to treatment with LFUM and simvastatin in combination. Furthermore, this inhibitory effect was enhanced in a time-dependent manner. For cell apoptosis, a low dose of simvastatin had no apparent affect on the DU145 cells, while LFU marginally promoted cell apoptosis. Microbubbles or simvastatin increased the apoptosis rate of the DU145 cells, however, the combination of LFUM and simvastatin induced a strong synergistic effect on cell apoptosis. Western blotting analysis demonstrated a high expression level of caveolin-1 in resting DU145 cells. LFUM or combined LFU and simvastatin resulted in a greater reduction in the expression compared with the control group (P<0.05). The expression of caveolin-1 was lowest in the LFUM combined with simvastatin treatment group. The expression of phospho-Akt (p-Akt) was consistent with caveolin-1, with the lowest expression levels of p-Akt observed in the cells that were treated with the combination of LFUM and simvastatin. The results indicate that LFUM in combination with simvastatin may additively or synergistically inhibit cell viability and induce apoptosis of DU145 cells by downregulating caveolin-1 and p-Akt protein expression. |
format | Online Article Text |
id | pubmed-4049715 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | D.A. Spandidos |
record_format | MEDLINE/PubMed |
spelling | pubmed-40497152014-06-13 Enhanced antitumor effects of low-frequency ultrasound and microbubbles in combination with simvastatin by downregulating caveolin-1 in prostatic DU145 cells XU, WEI-PING SHEN, E. BAI, WEN-KUN WANG, YU HU, BING Oncol Lett Articles Advanced prostate cancer is difficult to treat due to androgen resistance, its deep location and blood tumor barriers. Low-frequency ultrasound (LFU) has potential clinical applications in the treatment of prostate cancer due to its strong penetrability and high sensitivity towards tumor cells. Simvastatin has often been administered as a preventive agent in prostate tumors. The aim of the present study was to investigate the enhanced effects of LFU and microbubbles in combination with simvastatin, in inhibiting cell viability and promoting apoptosis of androgen-independent prostatic DU145 cells. Cultured DU145 cells were divided into six groups based on the combination of treatments as follows: Control, LFU, LFU and microbubbles (LFUM), simvastatin, LFU and simvastatin, LFUM and simvastatin. The cells were treated by LFU (80 kHz) continuously for 30 sec with an ultrasound intensity of 0.45 W/cm(2) and a microbubble density of 20%. Simvastatin was added 30 h prior to the ultrasound exposure. The results indicated that cell viability was marginally reduced in the LFU and simvastatin alone treatment groups compared with the control 24 h following ultrasound exposure. The combination of LFU, with microbubbles or simvastatin, potentiated the growth inhibition; the greatest inhibition was observed in the cells that were subject to treatment with LFUM and simvastatin in combination. Furthermore, this inhibitory effect was enhanced in a time-dependent manner. For cell apoptosis, a low dose of simvastatin had no apparent affect on the DU145 cells, while LFU marginally promoted cell apoptosis. Microbubbles or simvastatin increased the apoptosis rate of the DU145 cells, however, the combination of LFUM and simvastatin induced a strong synergistic effect on cell apoptosis. Western blotting analysis demonstrated a high expression level of caveolin-1 in resting DU145 cells. LFUM or combined LFU and simvastatin resulted in a greater reduction in the expression compared with the control group (P<0.05). The expression of caveolin-1 was lowest in the LFUM combined with simvastatin treatment group. The expression of phospho-Akt (p-Akt) was consistent with caveolin-1, with the lowest expression levels of p-Akt observed in the cells that were treated with the combination of LFUM and simvastatin. The results indicate that LFUM in combination with simvastatin may additively or synergistically inhibit cell viability and induce apoptosis of DU145 cells by downregulating caveolin-1 and p-Akt protein expression. D.A. Spandidos 2014-06 2014-03-28 /pmc/articles/PMC4049715/ /pubmed/24932304 http://dx.doi.org/10.3892/ol.2014.2005 Text en Copyright © 2014, Spandidos Publications http://creativecommons.org/licenses/by/3.0 This is an open-access article licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported License. The article may be redistributed, reproduced, and reused for non-commercial purposes, provided the original source is properly cited. |
spellingShingle | Articles XU, WEI-PING SHEN, E. BAI, WEN-KUN WANG, YU HU, BING Enhanced antitumor effects of low-frequency ultrasound and microbubbles in combination with simvastatin by downregulating caveolin-1 in prostatic DU145 cells |
title | Enhanced antitumor effects of low-frequency ultrasound and microbubbles in combination with simvastatin by downregulating caveolin-1 in prostatic DU145 cells |
title_full | Enhanced antitumor effects of low-frequency ultrasound and microbubbles in combination with simvastatin by downregulating caveolin-1 in prostatic DU145 cells |
title_fullStr | Enhanced antitumor effects of low-frequency ultrasound and microbubbles in combination with simvastatin by downregulating caveolin-1 in prostatic DU145 cells |
title_full_unstemmed | Enhanced antitumor effects of low-frequency ultrasound and microbubbles in combination with simvastatin by downregulating caveolin-1 in prostatic DU145 cells |
title_short | Enhanced antitumor effects of low-frequency ultrasound and microbubbles in combination with simvastatin by downregulating caveolin-1 in prostatic DU145 cells |
title_sort | enhanced antitumor effects of low-frequency ultrasound and microbubbles in combination with simvastatin by downregulating caveolin-1 in prostatic du145 cells |
topic | Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4049715/ https://www.ncbi.nlm.nih.gov/pubmed/24932304 http://dx.doi.org/10.3892/ol.2014.2005 |
work_keys_str_mv | AT xuweiping enhancedantitumoreffectsoflowfrequencyultrasoundandmicrobubblesincombinationwithsimvastatinbydownregulatingcaveolin1inprostaticdu145cells AT shene enhancedantitumoreffectsoflowfrequencyultrasoundandmicrobubblesincombinationwithsimvastatinbydownregulatingcaveolin1inprostaticdu145cells AT baiwenkun enhancedantitumoreffectsoflowfrequencyultrasoundandmicrobubblesincombinationwithsimvastatinbydownregulatingcaveolin1inprostaticdu145cells AT wangyu enhancedantitumoreffectsoflowfrequencyultrasoundandmicrobubblesincombinationwithsimvastatinbydownregulatingcaveolin1inprostaticdu145cells AT hubing enhancedantitumoreffectsoflowfrequencyultrasoundandmicrobubblesincombinationwithsimvastatinbydownregulatingcaveolin1inprostaticdu145cells |