Cargando…

Image Quality and Radiation Dose of Lower Extremity CT Angiography Using 70 kVp, High Pitch Acquisition and Sinogram-Affirmed Iterative Reconstruction

OBJECTIVES: The purpose of this study was to assess image quality and radiation dose of lower extremity CT angiography (CTA) with 70 kVp, high pitch acquisition and sinogram-affirmed iterative reconstruction (SAFIRE). METHODS: Lower extremity CTAs were performed on 44 patients: 22 patients were exam...

Descripción completa

Detalles Bibliográficos
Autores principales: Qi, Li, Meinel, Felix G., Zhou, Chang Sheng, Zhao, Yan E., Schoepf, U. Joseph, Zhang, Long Jiang, Lu, Guang Ming
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4051648/
https://www.ncbi.nlm.nih.gov/pubmed/24915439
http://dx.doi.org/10.1371/journal.pone.0099112
_version_ 1782320119413735424
author Qi, Li
Meinel, Felix G.
Zhou, Chang Sheng
Zhao, Yan E.
Schoepf, U. Joseph
Zhang, Long Jiang
Lu, Guang Ming
author_facet Qi, Li
Meinel, Felix G.
Zhou, Chang Sheng
Zhao, Yan E.
Schoepf, U. Joseph
Zhang, Long Jiang
Lu, Guang Ming
author_sort Qi, Li
collection PubMed
description OBJECTIVES: The purpose of this study was to assess image quality and radiation dose of lower extremity CT angiography (CTA) with 70 kVp, high pitch acquisition and sinogram-affirmed iterative reconstruction (SAFIRE). METHODS: Lower extremity CTAs were performed on 44 patients: 22 patients were examined using protocol A (120 kVp, pitch of 0.85 and 120 ml of contrast agent on a first-generation dual-source CT) (120 kVp group) and 22 patients were evaluated with protocol B (70 kVp, pitch of 2.2 and 80 ml of contrast agent on a second-generation dual-source CT) (70 kVp group). Images from the 120 kVp group were reconstructed with filtered back projection (FBP) and images from the 70 kVp group with SAFIRE. The attenuation, image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Two radiologists subjectively assessed image quality of lower extremity arteries, plantar arterial enhancement and venous contamination of all patients. Radiation dose was compared between the two groups. RESULTS: Higher mean intravascular attenuation was obtained in the 70 kVp group (70 vs. 120 kVp group, 555.4±83.4 HU vs. 300.9±81.4 HU, P<0.001), as well as image noise (20.0±2.8 HU vs. 17.5±3.2 HU, P = 0.010), SNR (32.0±7.0 vs. 19.1±6.9, P<0.001) and CNR (28.1±6.6 vs 15.9±6.3, P<0.001). No difference in subjective image quality and plantar arterial enhancement was found between 120 kVp group and 70 kVp group (all P>0.05). The venous contamination score was 1.5±0.8 for 120 kVp group while no venous contamination was found in 70 kVp group. The inter-observer agreement was moderate to good for both groups (0.515∼1, P<0.001). The effective dose was lower in 70 kVp group (0.3±0.1 mSv) than in 120 kVp group (1.6±0.7 mSv)(P<0.001). CONCLUSIONS: Lower extremity CTA using 70 kVp, high pitch acquisition and SAFIRE, except increasing imaging noise, allows for lower radiation dose and contrast material volume without compromising image quality.
format Online
Article
Text
id pubmed-4051648
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-40516482014-06-18 Image Quality and Radiation Dose of Lower Extremity CT Angiography Using 70 kVp, High Pitch Acquisition and Sinogram-Affirmed Iterative Reconstruction Qi, Li Meinel, Felix G. Zhou, Chang Sheng Zhao, Yan E. Schoepf, U. Joseph Zhang, Long Jiang Lu, Guang Ming PLoS One Research Article OBJECTIVES: The purpose of this study was to assess image quality and radiation dose of lower extremity CT angiography (CTA) with 70 kVp, high pitch acquisition and sinogram-affirmed iterative reconstruction (SAFIRE). METHODS: Lower extremity CTAs were performed on 44 patients: 22 patients were examined using protocol A (120 kVp, pitch of 0.85 and 120 ml of contrast agent on a first-generation dual-source CT) (120 kVp group) and 22 patients were evaluated with protocol B (70 kVp, pitch of 2.2 and 80 ml of contrast agent on a second-generation dual-source CT) (70 kVp group). Images from the 120 kVp group were reconstructed with filtered back projection (FBP) and images from the 70 kVp group with SAFIRE. The attenuation, image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Two radiologists subjectively assessed image quality of lower extremity arteries, plantar arterial enhancement and venous contamination of all patients. Radiation dose was compared between the two groups. RESULTS: Higher mean intravascular attenuation was obtained in the 70 kVp group (70 vs. 120 kVp group, 555.4±83.4 HU vs. 300.9±81.4 HU, P<0.001), as well as image noise (20.0±2.8 HU vs. 17.5±3.2 HU, P = 0.010), SNR (32.0±7.0 vs. 19.1±6.9, P<0.001) and CNR (28.1±6.6 vs 15.9±6.3, P<0.001). No difference in subjective image quality and plantar arterial enhancement was found between 120 kVp group and 70 kVp group (all P>0.05). The venous contamination score was 1.5±0.8 for 120 kVp group while no venous contamination was found in 70 kVp group. The inter-observer agreement was moderate to good for both groups (0.515∼1, P<0.001). The effective dose was lower in 70 kVp group (0.3±0.1 mSv) than in 120 kVp group (1.6±0.7 mSv)(P<0.001). CONCLUSIONS: Lower extremity CTA using 70 kVp, high pitch acquisition and SAFIRE, except increasing imaging noise, allows for lower radiation dose and contrast material volume without compromising image quality. Public Library of Science 2014-06-10 /pmc/articles/PMC4051648/ /pubmed/24915439 http://dx.doi.org/10.1371/journal.pone.0099112 Text en © 2014 Qi et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Qi, Li
Meinel, Felix G.
Zhou, Chang Sheng
Zhao, Yan E.
Schoepf, U. Joseph
Zhang, Long Jiang
Lu, Guang Ming
Image Quality and Radiation Dose of Lower Extremity CT Angiography Using 70 kVp, High Pitch Acquisition and Sinogram-Affirmed Iterative Reconstruction
title Image Quality and Radiation Dose of Lower Extremity CT Angiography Using 70 kVp, High Pitch Acquisition and Sinogram-Affirmed Iterative Reconstruction
title_full Image Quality and Radiation Dose of Lower Extremity CT Angiography Using 70 kVp, High Pitch Acquisition and Sinogram-Affirmed Iterative Reconstruction
title_fullStr Image Quality and Radiation Dose of Lower Extremity CT Angiography Using 70 kVp, High Pitch Acquisition and Sinogram-Affirmed Iterative Reconstruction
title_full_unstemmed Image Quality and Radiation Dose of Lower Extremity CT Angiography Using 70 kVp, High Pitch Acquisition and Sinogram-Affirmed Iterative Reconstruction
title_short Image Quality and Radiation Dose of Lower Extremity CT Angiography Using 70 kVp, High Pitch Acquisition and Sinogram-Affirmed Iterative Reconstruction
title_sort image quality and radiation dose of lower extremity ct angiography using 70 kvp, high pitch acquisition and sinogram-affirmed iterative reconstruction
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4051648/
https://www.ncbi.nlm.nih.gov/pubmed/24915439
http://dx.doi.org/10.1371/journal.pone.0099112
work_keys_str_mv AT qili imagequalityandradiationdoseoflowerextremityctangiographyusing70kvphighpitchacquisitionandsinogramaffirmediterativereconstruction
AT meinelfelixg imagequalityandradiationdoseoflowerextremityctangiographyusing70kvphighpitchacquisitionandsinogramaffirmediterativereconstruction
AT zhouchangsheng imagequalityandradiationdoseoflowerextremityctangiographyusing70kvphighpitchacquisitionandsinogramaffirmediterativereconstruction
AT zhaoyane imagequalityandradiationdoseoflowerextremityctangiographyusing70kvphighpitchacquisitionandsinogramaffirmediterativereconstruction
AT schoepfujoseph imagequalityandradiationdoseoflowerextremityctangiographyusing70kvphighpitchacquisitionandsinogramaffirmediterativereconstruction
AT zhanglongjiang imagequalityandradiationdoseoflowerextremityctangiographyusing70kvphighpitchacquisitionandsinogramaffirmediterativereconstruction
AT luguangming imagequalityandradiationdoseoflowerextremityctangiographyusing70kvphighpitchacquisitionandsinogramaffirmediterativereconstruction