Cargando…
Treatment of Unstable Thoracolumbar Fractures through Short Segment Pedicle Screw Fixation Techniques Using Pedicle Fixation at the Level of the Fracture: A Finite Element Analysis
OBJECTIVE: To compare the von Mises stresses of the internal fixation devices among different short segment pedicle screw fixation techniques to treat thoracic 12 vertebral fractures, especially the mono-segment pedicle screw fixation and intermediate unilateral pedicle screw fixation techniques. ME...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4051693/ https://www.ncbi.nlm.nih.gov/pubmed/24914815 http://dx.doi.org/10.1371/journal.pone.0099156 |
_version_ | 1782320129688731648 |
---|---|
author | Li, Changqing Zhou, Yue Wang, Hongwei Liu, Jun Xiang, Liangbi |
author_facet | Li, Changqing Zhou, Yue Wang, Hongwei Liu, Jun Xiang, Liangbi |
author_sort | Li, Changqing |
collection | PubMed |
description | OBJECTIVE: To compare the von Mises stresses of the internal fixation devices among different short segment pedicle screw fixation techniques to treat thoracic 12 vertebral fractures, especially the mono-segment pedicle screw fixation and intermediate unilateral pedicle screw fixation techniques. METHODS: Finite element methods were utilised to investigate the biomechanical comparison of the four posterior short segment pedicle screw fixation techniques (S4+2: traditional short-segment 4 pedicle screw fixation [SPSF]; M4+2: mono-segment pedicle screw fixation; I6+2: intermediate bilateral pedicle screw fixation; and I5+2: intermediate unilateral pedicle screw fixation). RESULTS: The range of motion (ROM) in flexion, axial rotation, and lateral bending was the smallest in the I6+2 fixation model, followed by the I5+2 and S4+2 fixation models, but lateral bending was the largest in the M4+2 fixation model. The maximal stress of the upper pedicle screw is larger than the lower pedicle screw in S4+2 and M4+2. The largest maximal von Mises stress was observed in the upper pedicle screw in the S4+2 and M4+2 fixation models and in the lower pedicle screw in the I6+2 and I5+2 fixation models. The values of the largest maximal von Mises stress of the pedicle screws and rods during all states of motion were 263.1 MPa and 304.5 MPa in the S4+2 fixation model, 291.6 MPa and 340.5 MPa in the M4+2 fixation model, 182.9 MPa and 263.2 MPa in the I6+2 fixation model, and 269.3 MPa and 383.7 MPa in the I5+2 fixation model, respectively. Comparing the stress between different spinal loadings, the maximal von Mises stress of the implants were observed in flexion in all implanted models. CONCLUSION: Additional bilateral pedicle screws at the level of the fracture to SPSF may result in a stiffer construct and less von Mises stress for pedicle screws and rods. The largest maximal von Mises stress of the pedicle screws during all states of motion were observed in the mono-segment pedicle screw fixation technique. |
format | Online Article Text |
id | pubmed-4051693 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-40516932014-06-18 Treatment of Unstable Thoracolumbar Fractures through Short Segment Pedicle Screw Fixation Techniques Using Pedicle Fixation at the Level of the Fracture: A Finite Element Analysis Li, Changqing Zhou, Yue Wang, Hongwei Liu, Jun Xiang, Liangbi PLoS One Research Article OBJECTIVE: To compare the von Mises stresses of the internal fixation devices among different short segment pedicle screw fixation techniques to treat thoracic 12 vertebral fractures, especially the mono-segment pedicle screw fixation and intermediate unilateral pedicle screw fixation techniques. METHODS: Finite element methods were utilised to investigate the biomechanical comparison of the four posterior short segment pedicle screw fixation techniques (S4+2: traditional short-segment 4 pedicle screw fixation [SPSF]; M4+2: mono-segment pedicle screw fixation; I6+2: intermediate bilateral pedicle screw fixation; and I5+2: intermediate unilateral pedicle screw fixation). RESULTS: The range of motion (ROM) in flexion, axial rotation, and lateral bending was the smallest in the I6+2 fixation model, followed by the I5+2 and S4+2 fixation models, but lateral bending was the largest in the M4+2 fixation model. The maximal stress of the upper pedicle screw is larger than the lower pedicle screw in S4+2 and M4+2. The largest maximal von Mises stress was observed in the upper pedicle screw in the S4+2 and M4+2 fixation models and in the lower pedicle screw in the I6+2 and I5+2 fixation models. The values of the largest maximal von Mises stress of the pedicle screws and rods during all states of motion were 263.1 MPa and 304.5 MPa in the S4+2 fixation model, 291.6 MPa and 340.5 MPa in the M4+2 fixation model, 182.9 MPa and 263.2 MPa in the I6+2 fixation model, and 269.3 MPa and 383.7 MPa in the I5+2 fixation model, respectively. Comparing the stress between different spinal loadings, the maximal von Mises stress of the implants were observed in flexion in all implanted models. CONCLUSION: Additional bilateral pedicle screws at the level of the fracture to SPSF may result in a stiffer construct and less von Mises stress for pedicle screws and rods. The largest maximal von Mises stress of the pedicle screws during all states of motion were observed in the mono-segment pedicle screw fixation technique. Public Library of Science 2014-06-10 /pmc/articles/PMC4051693/ /pubmed/24914815 http://dx.doi.org/10.1371/journal.pone.0099156 Text en © 2014 Li et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Li, Changqing Zhou, Yue Wang, Hongwei Liu, Jun Xiang, Liangbi Treatment of Unstable Thoracolumbar Fractures through Short Segment Pedicle Screw Fixation Techniques Using Pedicle Fixation at the Level of the Fracture: A Finite Element Analysis |
title | Treatment of Unstable Thoracolumbar Fractures through Short Segment Pedicle Screw Fixation Techniques Using Pedicle Fixation at the Level of the Fracture: A Finite Element Analysis |
title_full | Treatment of Unstable Thoracolumbar Fractures through Short Segment Pedicle Screw Fixation Techniques Using Pedicle Fixation at the Level of the Fracture: A Finite Element Analysis |
title_fullStr | Treatment of Unstable Thoracolumbar Fractures through Short Segment Pedicle Screw Fixation Techniques Using Pedicle Fixation at the Level of the Fracture: A Finite Element Analysis |
title_full_unstemmed | Treatment of Unstable Thoracolumbar Fractures through Short Segment Pedicle Screw Fixation Techniques Using Pedicle Fixation at the Level of the Fracture: A Finite Element Analysis |
title_short | Treatment of Unstable Thoracolumbar Fractures through Short Segment Pedicle Screw Fixation Techniques Using Pedicle Fixation at the Level of the Fracture: A Finite Element Analysis |
title_sort | treatment of unstable thoracolumbar fractures through short segment pedicle screw fixation techniques using pedicle fixation at the level of the fracture: a finite element analysis |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4051693/ https://www.ncbi.nlm.nih.gov/pubmed/24914815 http://dx.doi.org/10.1371/journal.pone.0099156 |
work_keys_str_mv | AT lichangqing treatmentofunstablethoracolumbarfracturesthroughshortsegmentpediclescrewfixationtechniquesusingpediclefixationatthelevelofthefractureafiniteelementanalysis AT zhouyue treatmentofunstablethoracolumbarfracturesthroughshortsegmentpediclescrewfixationtechniquesusingpediclefixationatthelevelofthefractureafiniteelementanalysis AT wanghongwei treatmentofunstablethoracolumbarfracturesthroughshortsegmentpediclescrewfixationtechniquesusingpediclefixationatthelevelofthefractureafiniteelementanalysis AT liujun treatmentofunstablethoracolumbarfracturesthroughshortsegmentpediclescrewfixationtechniquesusingpediclefixationatthelevelofthefractureafiniteelementanalysis AT xiangliangbi treatmentofunstablethoracolumbarfracturesthroughshortsegmentpediclescrewfixationtechniquesusingpediclefixationatthelevelofthefractureafiniteelementanalysis |