Cargando…

Calculation of Reaction Forces in the Boiler Supports Using the Method of Equivalent Stiffness of Membrane Wall

The values of reaction forces in the boiler supports are the basis for the dimensioning of bearing steel structure of steam boiler. In this paper, the application of the method of equivalent stiffness of membrane wall is proposed for the calculation of reaction forces. The method of equalizing displ...

Descripción completa

Detalles Bibliográficos
Autores principales: Sertić, Josip, Kozak, Dražan, Samardžić, Ivan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4052505/
https://www.ncbi.nlm.nih.gov/pubmed/24959612
http://dx.doi.org/10.1155/2014/392048
_version_ 1782320243740246016
author Sertić, Josip
Kozak, Dražan
Samardžić, Ivan
author_facet Sertić, Josip
Kozak, Dražan
Samardžić, Ivan
author_sort Sertić, Josip
collection PubMed
description The values of reaction forces in the boiler supports are the basis for the dimensioning of bearing steel structure of steam boiler. In this paper, the application of the method of equivalent stiffness of membrane wall is proposed for the calculation of reaction forces. The method of equalizing displacement, as the method of homogenization of membrane wall stiffness, was applied. On the example of “Milano” boiler, using the finite element method, the calculation of reactions in the supports for the real geometry discretized by the shell finite element was made. The second calculation was performed with the assumption of ideal stiffness of membrane walls and the third using the method of equivalent stiffness of membrane wall. In the third case, the membrane walls are approximated by the equivalent orthotropic plate. The approximation of membrane wall stiffness is achieved using the elasticity matrix of equivalent orthotropic plate at the level of finite element. The obtained results were compared, and the advantages of using the method of equivalent stiffness of membrane wall for the calculation of reactions in the boiler supports were emphasized.
format Online
Article
Text
id pubmed-4052505
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-40525052014-06-23 Calculation of Reaction Forces in the Boiler Supports Using the Method of Equivalent Stiffness of Membrane Wall Sertić, Josip Kozak, Dražan Samardžić, Ivan ScientificWorldJournal Research Article The values of reaction forces in the boiler supports are the basis for the dimensioning of bearing steel structure of steam boiler. In this paper, the application of the method of equivalent stiffness of membrane wall is proposed for the calculation of reaction forces. The method of equalizing displacement, as the method of homogenization of membrane wall stiffness, was applied. On the example of “Milano” boiler, using the finite element method, the calculation of reactions in the supports for the real geometry discretized by the shell finite element was made. The second calculation was performed with the assumption of ideal stiffness of membrane walls and the third using the method of equivalent stiffness of membrane wall. In the third case, the membrane walls are approximated by the equivalent orthotropic plate. The approximation of membrane wall stiffness is achieved using the elasticity matrix of equivalent orthotropic plate at the level of finite element. The obtained results were compared, and the advantages of using the method of equivalent stiffness of membrane wall for the calculation of reactions in the boiler supports were emphasized. Hindawi Publishing Corporation 2014 2014-05-15 /pmc/articles/PMC4052505/ /pubmed/24959612 http://dx.doi.org/10.1155/2014/392048 Text en Copyright © 2014 Josip Sertić et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Sertić, Josip
Kozak, Dražan
Samardžić, Ivan
Calculation of Reaction Forces in the Boiler Supports Using the Method of Equivalent Stiffness of Membrane Wall
title Calculation of Reaction Forces in the Boiler Supports Using the Method of Equivalent Stiffness of Membrane Wall
title_full Calculation of Reaction Forces in the Boiler Supports Using the Method of Equivalent Stiffness of Membrane Wall
title_fullStr Calculation of Reaction Forces in the Boiler Supports Using the Method of Equivalent Stiffness of Membrane Wall
title_full_unstemmed Calculation of Reaction Forces in the Boiler Supports Using the Method of Equivalent Stiffness of Membrane Wall
title_short Calculation of Reaction Forces in the Boiler Supports Using the Method of Equivalent Stiffness of Membrane Wall
title_sort calculation of reaction forces in the boiler supports using the method of equivalent stiffness of membrane wall
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4052505/
https://www.ncbi.nlm.nih.gov/pubmed/24959612
http://dx.doi.org/10.1155/2014/392048
work_keys_str_mv AT serticjosip calculationofreactionforcesintheboilersupportsusingthemethodofequivalentstiffnessofmembranewall
AT kozakdrazan calculationofreactionforcesintheboilersupportsusingthemethodofequivalentstiffnessofmembranewall
AT samardzicivan calculationofreactionforcesintheboilersupportsusingthemethodofequivalentstiffnessofmembranewall