Heat Removal from Bipolar Transistor by Loop Heat Pipe with Nickel and Copper Porous Structures

Loop heat pipes (LHPs) are used in many branches of industry, mainly for cooling of electrical elements and systems. The loop heat pipe is a vapour-liquid phase-change device that transfers heat from evaporator to condenser. One of the most important parts of the LHP is the porous wick structure. Th...

Descripción completa

Detalles Bibliográficos
Autores principales: Nemec, Patrik, Smitka, Martin, Malcho, Milan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4052570/
https://www.ncbi.nlm.nih.gov/pubmed/24959622
http://dx.doi.org/10.1155/2014/724740
_version_ 1782320255112052736
author Nemec, Patrik
Smitka, Martin
Malcho, Milan
author_facet Nemec, Patrik
Smitka, Martin
Malcho, Milan
author_sort Nemec, Patrik
collection PubMed
description Loop heat pipes (LHPs) are used in many branches of industry, mainly for cooling of electrical elements and systems. The loop heat pipe is a vapour-liquid phase-change device that transfers heat from evaporator to condenser. One of the most important parts of the LHP is the porous wick structure. The wick structure provides capillary force to circulate the working fluid. To achieve good thermal performance of LHP, capillary wicks with high permeability and porosity and fine pore radius are expected. The aim of this work was to develop porous structures from copper and nickel powder with different grain sizes. For experiment copper powder with grain size of 50 and 100 μm and nickel powder with grain size of 10 and 25 μm were used. Analysis of these porous structures and LHP design are described in the paper. And the measurements' influences of porous structures in LHP on heat removal from the insulated gate bipolar transistor (IGBT) have been made.
format Online
Article
Text
id pubmed-4052570
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-40525702014-06-23 Heat Removal from Bipolar Transistor by Loop Heat Pipe with Nickel and Copper Porous Structures Nemec, Patrik Smitka, Martin Malcho, Milan ScientificWorldJournal Research Article Loop heat pipes (LHPs) are used in many branches of industry, mainly for cooling of electrical elements and systems. The loop heat pipe is a vapour-liquid phase-change device that transfers heat from evaporator to condenser. One of the most important parts of the LHP is the porous wick structure. The wick structure provides capillary force to circulate the working fluid. To achieve good thermal performance of LHP, capillary wicks with high permeability and porosity and fine pore radius are expected. The aim of this work was to develop porous structures from copper and nickel powder with different grain sizes. For experiment copper powder with grain size of 50 and 100 μm and nickel powder with grain size of 10 and 25 μm were used. Analysis of these porous structures and LHP design are described in the paper. And the measurements' influences of porous structures in LHP on heat removal from the insulated gate bipolar transistor (IGBT) have been made. Hindawi Publishing Corporation 2014 2014-05-18 /pmc/articles/PMC4052570/ /pubmed/24959622 http://dx.doi.org/10.1155/2014/724740 Text en Copyright © 2014 Patrik Nemec et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Nemec, Patrik
Smitka, Martin
Malcho, Milan
Heat Removal from Bipolar Transistor by Loop Heat Pipe with Nickel and Copper Porous Structures
title Heat Removal from Bipolar Transistor by Loop Heat Pipe with Nickel and Copper Porous Structures
title_full Heat Removal from Bipolar Transistor by Loop Heat Pipe with Nickel and Copper Porous Structures
title_fullStr Heat Removal from Bipolar Transistor by Loop Heat Pipe with Nickel and Copper Porous Structures
title_full_unstemmed Heat Removal from Bipolar Transistor by Loop Heat Pipe with Nickel and Copper Porous Structures
title_short Heat Removal from Bipolar Transistor by Loop Heat Pipe with Nickel and Copper Porous Structures
title_sort heat removal from bipolar transistor by loop heat pipe with nickel and copper porous structures
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4052570/
https://www.ncbi.nlm.nih.gov/pubmed/24959622
http://dx.doi.org/10.1155/2014/724740
work_keys_str_mv AT nemecpatrik heatremovalfrombipolartransistorbyloopheatpipewithnickelandcopperporousstructures
AT smitkamartin heatremovalfrombipolartransistorbyloopheatpipewithnickelandcopperporousstructures
AT malchomilan heatremovalfrombipolartransistorbyloopheatpipewithnickelandcopperporousstructures