Cargando…
The Use of a Modular Titanium Baseplate with a Press-Fit Keel Implanted with a Surface Cementing Technique for Primary Total Knee Arthroplasty
Little data exists regarding outcomes following TKA performed with surface-cementation for the fixation of modular tibial baseplates with press-fit keels. Thus, we retrospectively reviewed the clinical and radiographic outcomes of 439 consecutive primary TKAs performed with surface cemented tibial c...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4052938/ https://www.ncbi.nlm.nih.gov/pubmed/24955373 http://dx.doi.org/10.1155/2014/972615 |
_version_ | 1782320309857157120 |
---|---|
author | Pelt, Christopher E. Erickson, Jill Christensen, Bryt A. Widmer, Benjamin Severson, Erik P. Evans, David Peters, Christopher L. |
author_facet | Pelt, Christopher E. Erickson, Jill Christensen, Bryt A. Widmer, Benjamin Severson, Erik P. Evans, David Peters, Christopher L. |
author_sort | Pelt, Christopher E. |
collection | PubMed |
description | Little data exists regarding outcomes following TKA performed with surface-cementation for the fixation of modular tibial baseplates with press-fit keels. Thus, we retrospectively reviewed the clinical and radiographic outcomes of 439 consecutive primary TKAs performed with surface cemented tibial components. There were 290 female patients and 149 male patients with average age of 62 years (range 30–84). Two tibial components were revised for aseptic loosening (0.5%) and four tibial components (0.9%) were removed to improve instability (n = 2) or malalignment (n = 2). Complications included 13 deep infections treated with 2-stage revision (12) and fusion (1). These results support the surface cement technique with a modular grit-blasted titanium surface and cruciform stem during primary TKA. |
format | Online Article Text |
id | pubmed-4052938 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-40529382014-06-22 The Use of a Modular Titanium Baseplate with a Press-Fit Keel Implanted with a Surface Cementing Technique for Primary Total Knee Arthroplasty Pelt, Christopher E. Erickson, Jill Christensen, Bryt A. Widmer, Benjamin Severson, Erik P. Evans, David Peters, Christopher L. Biomed Res Int Research Article Little data exists regarding outcomes following TKA performed with surface-cementation for the fixation of modular tibial baseplates with press-fit keels. Thus, we retrospectively reviewed the clinical and radiographic outcomes of 439 consecutive primary TKAs performed with surface cemented tibial components. There were 290 female patients and 149 male patients with average age of 62 years (range 30–84). Two tibial components were revised for aseptic loosening (0.5%) and four tibial components (0.9%) were removed to improve instability (n = 2) or malalignment (n = 2). Complications included 13 deep infections treated with 2-stage revision (12) and fusion (1). These results support the surface cement technique with a modular grit-blasted titanium surface and cruciform stem during primary TKA. Hindawi Publishing Corporation 2014 2014-05-14 /pmc/articles/PMC4052938/ /pubmed/24955373 http://dx.doi.org/10.1155/2014/972615 Text en Copyright © 2014 Christopher E. Pelt et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Pelt, Christopher E. Erickson, Jill Christensen, Bryt A. Widmer, Benjamin Severson, Erik P. Evans, David Peters, Christopher L. The Use of a Modular Titanium Baseplate with a Press-Fit Keel Implanted with a Surface Cementing Technique for Primary Total Knee Arthroplasty |
title | The Use of a Modular Titanium Baseplate with a Press-Fit Keel Implanted with a Surface Cementing Technique for Primary Total Knee Arthroplasty |
title_full | The Use of a Modular Titanium Baseplate with a Press-Fit Keel Implanted with a Surface Cementing Technique for Primary Total Knee Arthroplasty |
title_fullStr | The Use of a Modular Titanium Baseplate with a Press-Fit Keel Implanted with a Surface Cementing Technique for Primary Total Knee Arthroplasty |
title_full_unstemmed | The Use of a Modular Titanium Baseplate with a Press-Fit Keel Implanted with a Surface Cementing Technique for Primary Total Knee Arthroplasty |
title_short | The Use of a Modular Titanium Baseplate with a Press-Fit Keel Implanted with a Surface Cementing Technique for Primary Total Knee Arthroplasty |
title_sort | use of a modular titanium baseplate with a press-fit keel implanted with a surface cementing technique for primary total knee arthroplasty |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4052938/ https://www.ncbi.nlm.nih.gov/pubmed/24955373 http://dx.doi.org/10.1155/2014/972615 |
work_keys_str_mv | AT peltchristophere theuseofamodulartitaniumbaseplatewithapressfitkeelimplantedwithasurfacecementingtechniqueforprimarytotalkneearthroplasty AT ericksonjill theuseofamodulartitaniumbaseplatewithapressfitkeelimplantedwithasurfacecementingtechniqueforprimarytotalkneearthroplasty AT christensenbryta theuseofamodulartitaniumbaseplatewithapressfitkeelimplantedwithasurfacecementingtechniqueforprimarytotalkneearthroplasty AT widmerbenjamin theuseofamodulartitaniumbaseplatewithapressfitkeelimplantedwithasurfacecementingtechniqueforprimarytotalkneearthroplasty AT seversonerikp theuseofamodulartitaniumbaseplatewithapressfitkeelimplantedwithasurfacecementingtechniqueforprimarytotalkneearthroplasty AT evansdavid theuseofamodulartitaniumbaseplatewithapressfitkeelimplantedwithasurfacecementingtechniqueforprimarytotalkneearthroplasty AT peterschristopherl theuseofamodulartitaniumbaseplatewithapressfitkeelimplantedwithasurfacecementingtechniqueforprimarytotalkneearthroplasty AT peltchristophere useofamodulartitaniumbaseplatewithapressfitkeelimplantedwithasurfacecementingtechniqueforprimarytotalkneearthroplasty AT ericksonjill useofamodulartitaniumbaseplatewithapressfitkeelimplantedwithasurfacecementingtechniqueforprimarytotalkneearthroplasty AT christensenbryta useofamodulartitaniumbaseplatewithapressfitkeelimplantedwithasurfacecementingtechniqueforprimarytotalkneearthroplasty AT widmerbenjamin useofamodulartitaniumbaseplatewithapressfitkeelimplantedwithasurfacecementingtechniqueforprimarytotalkneearthroplasty AT seversonerikp useofamodulartitaniumbaseplatewithapressfitkeelimplantedwithasurfacecementingtechniqueforprimarytotalkneearthroplasty AT evansdavid useofamodulartitaniumbaseplatewithapressfitkeelimplantedwithasurfacecementingtechniqueforprimarytotalkneearthroplasty AT peterschristopherl useofamodulartitaniumbaseplatewithapressfitkeelimplantedwithasurfacecementingtechniqueforprimarytotalkneearthroplasty |