Microdosimetric Analysis Confirms Similar Biological Effectiveness of External Exposure to Gamma-Rays and Internal Exposure to (137)Cs, (134)Cs, and (131)I
The risk of internal exposure to (137)Cs, (134)Cs, and (131)I is of great public concern after the accident at the Fukushima-Daiichi nuclear power plant. The relative biological effectiveness (RBE, defined herein as effectiveness of internal exposure relative to the external exposure to γ-rays) is o...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4053446/ https://www.ncbi.nlm.nih.gov/pubmed/24919099 http://dx.doi.org/10.1371/journal.pone.0099831 |
_version_ | 1782320382712217600 |
---|---|
author | Sato, Tatsuhiko Manabe, Kentaro Hamada, Nobuyuki |
author_facet | Sato, Tatsuhiko Manabe, Kentaro Hamada, Nobuyuki |
author_sort | Sato, Tatsuhiko |
collection | PubMed |
description | The risk of internal exposure to (137)Cs, (134)Cs, and (131)I is of great public concern after the accident at the Fukushima-Daiichi nuclear power plant. The relative biological effectiveness (RBE, defined herein as effectiveness of internal exposure relative to the external exposure to γ-rays) is occasionally believed to be much greater than unity due to insufficient discussions on the difference of their microdosimetric profiles. We therefore performed a Monte Carlo particle transport simulation in ideally aligned cell systems to calculate the probability densities of absorbed doses in subcellular and intranuclear scales for internal exposures to electrons emitted from (137)Cs, (134)Cs, and (131)I, as well as the external exposure to 662 keV photons. The RBE due to the inhomogeneous radioactive isotope (RI) distribution in subcellular structures and the high ionization density around the particle trajectories was then derived from the calculated microdosimetric probability density. The RBE for the bystander effect was also estimated from the probability density, considering its non-linear dose response. The RBE due to the high ionization density and that for the bystander effect were very close to 1, because the microdosimetric probability densities were nearly identical between the internal exposures and the external exposure from the 662 keV photons. On the other hand, the RBE due to the RI inhomogeneity largely depended on the intranuclear RI concentration and cell size, but their maximum possible RBE was only 1.04 even under conservative assumptions. Thus, it can be concluded from the microdosimetric viewpoint that the risk from internal exposures to (137)Cs, (134)Cs, and (131)I should be nearly equivalent to that of external exposure to γ-rays at the same absorbed dose level, as suggested in the current recommendations of the International Commission on Radiological Protection. |
format | Online Article Text |
id | pubmed-4053446 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-40534462014-06-18 Microdosimetric Analysis Confirms Similar Biological Effectiveness of External Exposure to Gamma-Rays and Internal Exposure to (137)Cs, (134)Cs, and (131)I Sato, Tatsuhiko Manabe, Kentaro Hamada, Nobuyuki PLoS One Research Article The risk of internal exposure to (137)Cs, (134)Cs, and (131)I is of great public concern after the accident at the Fukushima-Daiichi nuclear power plant. The relative biological effectiveness (RBE, defined herein as effectiveness of internal exposure relative to the external exposure to γ-rays) is occasionally believed to be much greater than unity due to insufficient discussions on the difference of their microdosimetric profiles. We therefore performed a Monte Carlo particle transport simulation in ideally aligned cell systems to calculate the probability densities of absorbed doses in subcellular and intranuclear scales for internal exposures to electrons emitted from (137)Cs, (134)Cs, and (131)I, as well as the external exposure to 662 keV photons. The RBE due to the inhomogeneous radioactive isotope (RI) distribution in subcellular structures and the high ionization density around the particle trajectories was then derived from the calculated microdosimetric probability density. The RBE for the bystander effect was also estimated from the probability density, considering its non-linear dose response. The RBE due to the high ionization density and that for the bystander effect were very close to 1, because the microdosimetric probability densities were nearly identical between the internal exposures and the external exposure from the 662 keV photons. On the other hand, the RBE due to the RI inhomogeneity largely depended on the intranuclear RI concentration and cell size, but their maximum possible RBE was only 1.04 even under conservative assumptions. Thus, it can be concluded from the microdosimetric viewpoint that the risk from internal exposures to (137)Cs, (134)Cs, and (131)I should be nearly equivalent to that of external exposure to γ-rays at the same absorbed dose level, as suggested in the current recommendations of the International Commission on Radiological Protection. Public Library of Science 2014-06-11 /pmc/articles/PMC4053446/ /pubmed/24919099 http://dx.doi.org/10.1371/journal.pone.0099831 Text en © 2014 Sato et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Sato, Tatsuhiko Manabe, Kentaro Hamada, Nobuyuki Microdosimetric Analysis Confirms Similar Biological Effectiveness of External Exposure to Gamma-Rays and Internal Exposure to (137)Cs, (134)Cs, and (131)I |
title | Microdosimetric Analysis Confirms Similar Biological Effectiveness of External Exposure to Gamma-Rays and Internal Exposure to (137)Cs, (134)Cs, and (131)I |
title_full | Microdosimetric Analysis Confirms Similar Biological Effectiveness of External Exposure to Gamma-Rays and Internal Exposure to (137)Cs, (134)Cs, and (131)I |
title_fullStr | Microdosimetric Analysis Confirms Similar Biological Effectiveness of External Exposure to Gamma-Rays and Internal Exposure to (137)Cs, (134)Cs, and (131)I |
title_full_unstemmed | Microdosimetric Analysis Confirms Similar Biological Effectiveness of External Exposure to Gamma-Rays and Internal Exposure to (137)Cs, (134)Cs, and (131)I |
title_short | Microdosimetric Analysis Confirms Similar Biological Effectiveness of External Exposure to Gamma-Rays and Internal Exposure to (137)Cs, (134)Cs, and (131)I |
title_sort | microdosimetric analysis confirms similar biological effectiveness of external exposure to gamma-rays and internal exposure to (137)cs, (134)cs, and (131)i |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4053446/ https://www.ncbi.nlm.nih.gov/pubmed/24919099 http://dx.doi.org/10.1371/journal.pone.0099831 |
work_keys_str_mv | AT satotatsuhiko microdosimetricanalysisconfirmssimilarbiologicaleffectivenessofexternalexposuretogammaraysandinternalexposureto137cs134csand131i AT manabekentaro microdosimetricanalysisconfirmssimilarbiologicaleffectivenessofexternalexposuretogammaraysandinternalexposureto137cs134csand131i AT hamadanobuyuki microdosimetricanalysisconfirmssimilarbiologicaleffectivenessofexternalexposuretogammaraysandinternalexposureto137cs134csand131i |