Cargando…

Squatting-Related Tibiofemoral Shear Reaction Forces and a Biomechanical Rationale for Femoral Component Loosening

Previous gait studies on squatting have described a rapid reversal in the direction of the tibiofemoral joint shear reaction force when going into a full weight-bearing deep knee flexion squat. The effects of such a shear reversal have not been considered with regard to the loading demand on knee im...

Descripción completa

Detalles Bibliográficos
Autores principales: Thambyah, Ashvin, Fernandez, Justin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4054786/
https://www.ncbi.nlm.nih.gov/pubmed/24982995
http://dx.doi.org/10.1155/2014/785175
_version_ 1782320544334479360
author Thambyah, Ashvin
Fernandez, Justin
author_facet Thambyah, Ashvin
Fernandez, Justin
author_sort Thambyah, Ashvin
collection PubMed
description Previous gait studies on squatting have described a rapid reversal in the direction of the tibiofemoral joint shear reaction force when going into a full weight-bearing deep knee flexion squat. The effects of such a shear reversal have not been considered with regard to the loading demand on knee implants in patients whose activities of daily living require frequent squatting. In this paper, the shear reversal effect is discussed and simulated in a finite element knee implant-bone model, to evaluate the possible biomechanical significance of this effect on femoral component loosening of high flexion implants as reported in the literature. The analysis shows that one of the effects of the shear reversal was a switch between large compressive and large tensile principal strains, from knee extension to flexion, respectively, in the region of the anterior flange of the femoral component. Together with the known material limits of cement and bone, this large mismatch in strains as a function of knee position provides new insight into how and why knee implants may fail in patients who perform frequent squatting.
format Online
Article
Text
id pubmed-4054786
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-40547862014-06-30 Squatting-Related Tibiofemoral Shear Reaction Forces and a Biomechanical Rationale for Femoral Component Loosening Thambyah, Ashvin Fernandez, Justin ScientificWorldJournal Research Article Previous gait studies on squatting have described a rapid reversal in the direction of the tibiofemoral joint shear reaction force when going into a full weight-bearing deep knee flexion squat. The effects of such a shear reversal have not been considered with regard to the loading demand on knee implants in patients whose activities of daily living require frequent squatting. In this paper, the shear reversal effect is discussed and simulated in a finite element knee implant-bone model, to evaluate the possible biomechanical significance of this effect on femoral component loosening of high flexion implants as reported in the literature. The analysis shows that one of the effects of the shear reversal was a switch between large compressive and large tensile principal strains, from knee extension to flexion, respectively, in the region of the anterior flange of the femoral component. Together with the known material limits of cement and bone, this large mismatch in strains as a function of knee position provides new insight into how and why knee implants may fail in patients who perform frequent squatting. Hindawi Publishing Corporation 2014 2014-05-20 /pmc/articles/PMC4054786/ /pubmed/24982995 http://dx.doi.org/10.1155/2014/785175 Text en Copyright © 2014 A. Thambyah and J. Fernandez. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Thambyah, Ashvin
Fernandez, Justin
Squatting-Related Tibiofemoral Shear Reaction Forces and a Biomechanical Rationale for Femoral Component Loosening
title Squatting-Related Tibiofemoral Shear Reaction Forces and a Biomechanical Rationale for Femoral Component Loosening
title_full Squatting-Related Tibiofemoral Shear Reaction Forces and a Biomechanical Rationale for Femoral Component Loosening
title_fullStr Squatting-Related Tibiofemoral Shear Reaction Forces and a Biomechanical Rationale for Femoral Component Loosening
title_full_unstemmed Squatting-Related Tibiofemoral Shear Reaction Forces and a Biomechanical Rationale for Femoral Component Loosening
title_short Squatting-Related Tibiofemoral Shear Reaction Forces and a Biomechanical Rationale for Femoral Component Loosening
title_sort squatting-related tibiofemoral shear reaction forces and a biomechanical rationale for femoral component loosening
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4054786/
https://www.ncbi.nlm.nih.gov/pubmed/24982995
http://dx.doi.org/10.1155/2014/785175
work_keys_str_mv AT thambyahashvin squattingrelatedtibiofemoralshearreactionforcesandabiomechanicalrationaleforfemoralcomponentloosening
AT fernandezjustin squattingrelatedtibiofemoralshearreactionforcesandabiomechanicalrationaleforfemoralcomponentloosening