Cargando…
Squatting-Related Tibiofemoral Shear Reaction Forces and a Biomechanical Rationale for Femoral Component Loosening
Previous gait studies on squatting have described a rapid reversal in the direction of the tibiofemoral joint shear reaction force when going into a full weight-bearing deep knee flexion squat. The effects of such a shear reversal have not been considered with regard to the loading demand on knee im...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4054786/ https://www.ncbi.nlm.nih.gov/pubmed/24982995 http://dx.doi.org/10.1155/2014/785175 |
_version_ | 1782320544334479360 |
---|---|
author | Thambyah, Ashvin Fernandez, Justin |
author_facet | Thambyah, Ashvin Fernandez, Justin |
author_sort | Thambyah, Ashvin |
collection | PubMed |
description | Previous gait studies on squatting have described a rapid reversal in the direction of the tibiofemoral joint shear reaction force when going into a full weight-bearing deep knee flexion squat. The effects of such a shear reversal have not been considered with regard to the loading demand on knee implants in patients whose activities of daily living require frequent squatting. In this paper, the shear reversal effect is discussed and simulated in a finite element knee implant-bone model, to evaluate the possible biomechanical significance of this effect on femoral component loosening of high flexion implants as reported in the literature. The analysis shows that one of the effects of the shear reversal was a switch between large compressive and large tensile principal strains, from knee extension to flexion, respectively, in the region of the anterior flange of the femoral component. Together with the known material limits of cement and bone, this large mismatch in strains as a function of knee position provides new insight into how and why knee implants may fail in patients who perform frequent squatting. |
format | Online Article Text |
id | pubmed-4054786 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-40547862014-06-30 Squatting-Related Tibiofemoral Shear Reaction Forces and a Biomechanical Rationale for Femoral Component Loosening Thambyah, Ashvin Fernandez, Justin ScientificWorldJournal Research Article Previous gait studies on squatting have described a rapid reversal in the direction of the tibiofemoral joint shear reaction force when going into a full weight-bearing deep knee flexion squat. The effects of such a shear reversal have not been considered with regard to the loading demand on knee implants in patients whose activities of daily living require frequent squatting. In this paper, the shear reversal effect is discussed and simulated in a finite element knee implant-bone model, to evaluate the possible biomechanical significance of this effect on femoral component loosening of high flexion implants as reported in the literature. The analysis shows that one of the effects of the shear reversal was a switch between large compressive and large tensile principal strains, from knee extension to flexion, respectively, in the region of the anterior flange of the femoral component. Together with the known material limits of cement and bone, this large mismatch in strains as a function of knee position provides new insight into how and why knee implants may fail in patients who perform frequent squatting. Hindawi Publishing Corporation 2014 2014-05-20 /pmc/articles/PMC4054786/ /pubmed/24982995 http://dx.doi.org/10.1155/2014/785175 Text en Copyright © 2014 A. Thambyah and J. Fernandez. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Thambyah, Ashvin Fernandez, Justin Squatting-Related Tibiofemoral Shear Reaction Forces and a Biomechanical Rationale for Femoral Component Loosening |
title | Squatting-Related Tibiofemoral Shear Reaction Forces and a Biomechanical Rationale for Femoral Component Loosening |
title_full | Squatting-Related Tibiofemoral Shear Reaction Forces and a Biomechanical Rationale for Femoral Component Loosening |
title_fullStr | Squatting-Related Tibiofemoral Shear Reaction Forces and a Biomechanical Rationale for Femoral Component Loosening |
title_full_unstemmed | Squatting-Related Tibiofemoral Shear Reaction Forces and a Biomechanical Rationale for Femoral Component Loosening |
title_short | Squatting-Related Tibiofemoral Shear Reaction Forces and a Biomechanical Rationale for Femoral Component Loosening |
title_sort | squatting-related tibiofemoral shear reaction forces and a biomechanical rationale for femoral component loosening |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4054786/ https://www.ncbi.nlm.nih.gov/pubmed/24982995 http://dx.doi.org/10.1155/2014/785175 |
work_keys_str_mv | AT thambyahashvin squattingrelatedtibiofemoralshearreactionforcesandabiomechanicalrationaleforfemoralcomponentloosening AT fernandezjustin squattingrelatedtibiofemoralshearreactionforcesandabiomechanicalrationaleforfemoralcomponentloosening |