Cargando…
Ambient x-ray pollution assessment at inspection gates of airports- a case study of Mehrabad and Imam Khomeini Airports in Iran
BACKGROUND: As a well-known, physical carcinogen, ambient X-ray pollution assessment would be of great importance in today’s modern world. Accordingly, the present study was done to measure the exposure level of ambient X-ray at inspection gates of two airports in Iran. According to which, the X-ray...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4054912/ https://www.ncbi.nlm.nih.gov/pubmed/24955243 http://dx.doi.org/10.1186/2052-336X-12-88 |
_version_ | 1782320565747449856 |
---|---|
author | Pourtaghi, Gholamhossein Valipour, Firouz Nourian, Sepideh Mofidi, Amirabbas |
author_facet | Pourtaghi, Gholamhossein Valipour, Firouz Nourian, Sepideh Mofidi, Amirabbas |
author_sort | Pourtaghi, Gholamhossein |
collection | PubMed |
description | BACKGROUND: As a well-known, physical carcinogen, ambient X-ray pollution assessment would be of great importance in today’s modern world. Accordingly, the present study was done to measure the exposure level of ambient X-ray at inspection gates of two airports in Iran. According to which, the X-ray was measured at different points of the inspection gates including closed and opened Curtain, as well as seating place of operators beside the X-ray inspection systems. The recorded data were then analyzed by “sign” and t-tests. RESULTS: The total average exposure level of the measured x-ray was 2.68 ± 0.73 μsv.h(-1). The measured x-ray exposure level was 2.07 ± 0.61 (μsv.h(-1)) released from RAPISCAN X-ray inspection system and 3.3 ± 1.34 (μsv.h(-1)) emitted from HEIMANN X-ray inspection system. Comparison of average x-ray doses of the systems in both airports showed that the minimum and maximum exposure levels were recorded at 1(m) far from the devices and at the entrance of the devices, respectively. CONCLUSIONS: The exposure levels at all measurement points were lower than the occupational exposure limit. This reveals the fact that the exposed operators are not probably at risk of adverse health effects. |
format | Online Article Text |
id | pubmed-4054912 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-40549122014-06-20 Ambient x-ray pollution assessment at inspection gates of airports- a case study of Mehrabad and Imam Khomeini Airports in Iran Pourtaghi, Gholamhossein Valipour, Firouz Nourian, Sepideh Mofidi, Amirabbas J Environ Health Sci Eng Research Article BACKGROUND: As a well-known, physical carcinogen, ambient X-ray pollution assessment would be of great importance in today’s modern world. Accordingly, the present study was done to measure the exposure level of ambient X-ray at inspection gates of two airports in Iran. According to which, the X-ray was measured at different points of the inspection gates including closed and opened Curtain, as well as seating place of operators beside the X-ray inspection systems. The recorded data were then analyzed by “sign” and t-tests. RESULTS: The total average exposure level of the measured x-ray was 2.68 ± 0.73 μsv.h(-1). The measured x-ray exposure level was 2.07 ± 0.61 (μsv.h(-1)) released from RAPISCAN X-ray inspection system and 3.3 ± 1.34 (μsv.h(-1)) emitted from HEIMANN X-ray inspection system. Comparison of average x-ray doses of the systems in both airports showed that the minimum and maximum exposure levels were recorded at 1(m) far from the devices and at the entrance of the devices, respectively. CONCLUSIONS: The exposure levels at all measurement points were lower than the occupational exposure limit. This reveals the fact that the exposed operators are not probably at risk of adverse health effects. BioMed Central 2014-05-28 /pmc/articles/PMC4054912/ /pubmed/24955243 http://dx.doi.org/10.1186/2052-336X-12-88 Text en Copyright © 2014 Pourtaghi et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Pourtaghi, Gholamhossein Valipour, Firouz Nourian, Sepideh Mofidi, Amirabbas Ambient x-ray pollution assessment at inspection gates of airports- a case study of Mehrabad and Imam Khomeini Airports in Iran |
title | Ambient x-ray pollution assessment at inspection gates of airports- a case study of Mehrabad and Imam Khomeini Airports in Iran |
title_full | Ambient x-ray pollution assessment at inspection gates of airports- a case study of Mehrabad and Imam Khomeini Airports in Iran |
title_fullStr | Ambient x-ray pollution assessment at inspection gates of airports- a case study of Mehrabad and Imam Khomeini Airports in Iran |
title_full_unstemmed | Ambient x-ray pollution assessment at inspection gates of airports- a case study of Mehrabad and Imam Khomeini Airports in Iran |
title_short | Ambient x-ray pollution assessment at inspection gates of airports- a case study of Mehrabad and Imam Khomeini Airports in Iran |
title_sort | ambient x-ray pollution assessment at inspection gates of airports- a case study of mehrabad and imam khomeini airports in iran |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4054912/ https://www.ncbi.nlm.nih.gov/pubmed/24955243 http://dx.doi.org/10.1186/2052-336X-12-88 |
work_keys_str_mv | AT pourtaghigholamhossein ambientxraypollutionassessmentatinspectiongatesofairportsacasestudyofmehrabadandimamkhomeiniairportsiniran AT valipourfirouz ambientxraypollutionassessmentatinspectiongatesofairportsacasestudyofmehrabadandimamkhomeiniairportsiniran AT nouriansepideh ambientxraypollutionassessmentatinspectiongatesofairportsacasestudyofmehrabadandimamkhomeiniairportsiniran AT mofidiamirabbas ambientxraypollutionassessmentatinspectiongatesofairportsacasestudyofmehrabadandimamkhomeiniairportsiniran |