Cargando…

Determination of Xanthine in the Presence of Hypoxanthine by Adsorptive Stripping Voltammetry at the Mercury Film Electrode

A stripping method for the determination of xanthine in the presence of hypoxanthine at the submicromolar concentration levels is described. The method is based on controlled adsorptive accumulation at the thin-film mercury electrode followed by a fast linear scan voltammetric measurement of the sur...

Descripción completa

Detalles Bibliográficos
Autores principales: Farias, Percio Augusto Mardini, Castro, Arnaldo Aguiar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Libertas Academica 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4055419/
https://www.ncbi.nlm.nih.gov/pubmed/24940040
http://dx.doi.org/10.4137/ACI.S14712
_version_ 1782320656446128128
author Farias, Percio Augusto Mardini
Castro, Arnaldo Aguiar
author_facet Farias, Percio Augusto Mardini
Castro, Arnaldo Aguiar
author_sort Farias, Percio Augusto Mardini
collection PubMed
description A stripping method for the determination of xanthine in the presence of hypoxanthine at the submicromolar concentration levels is described. The method is based on controlled adsorptive accumulation at the thin-film mercury electrode followed by a fast linear scan voltammetric measurement of the surface species. Optimum experimental conditions were found to be the use of 1.0 × 10(−3) mol L(−1) NaOH solution as supporting electrolyte, an accumulation potential of 0.00 V for xanthine and −0.50 V for hypoxanthine–copper, and a linear scan rate of 200 mV second(−1). The response of xanthine is linear over the concentration ranges of 20–140 ppb. For an accumulation time of 30 minutes, the detection limit was found to be 36 ppt (2.3 × 10(−10) mol L(−1)). Adequate conditions for measuring the xanthine in the presence of hypoxanthine, copper and other metals, uric acid, and other nitrogenated bases were also investigated. The utility of the method is demonstrated by the presence of xanthine associated with hypoxanthine, uric acid, nitrogenated bases, ATP, and ssDNA.
format Online
Article
Text
id pubmed-4055419
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Libertas Academica
record_format MEDLINE/PubMed
spelling pubmed-40554192014-06-17 Determination of Xanthine in the Presence of Hypoxanthine by Adsorptive Stripping Voltammetry at the Mercury Film Electrode Farias, Percio Augusto Mardini Castro, Arnaldo Aguiar Anal Chem Insights Original Research A stripping method for the determination of xanthine in the presence of hypoxanthine at the submicromolar concentration levels is described. The method is based on controlled adsorptive accumulation at the thin-film mercury electrode followed by a fast linear scan voltammetric measurement of the surface species. Optimum experimental conditions were found to be the use of 1.0 × 10(−3) mol L(−1) NaOH solution as supporting electrolyte, an accumulation potential of 0.00 V for xanthine and −0.50 V for hypoxanthine–copper, and a linear scan rate of 200 mV second(−1). The response of xanthine is linear over the concentration ranges of 20–140 ppb. For an accumulation time of 30 minutes, the detection limit was found to be 36 ppt (2.3 × 10(−10) mol L(−1)). Adequate conditions for measuring the xanthine in the presence of hypoxanthine, copper and other metals, uric acid, and other nitrogenated bases were also investigated. The utility of the method is demonstrated by the presence of xanthine associated with hypoxanthine, uric acid, nitrogenated bases, ATP, and ssDNA. Libertas Academica 2014-06-09 /pmc/articles/PMC4055419/ /pubmed/24940040 http://dx.doi.org/10.4137/ACI.S14712 Text en © 2014 the author(s), publisher and licensee Libertas Academica Ltd. This is an open access article published under the Creative Commons CC-BY-NC 3.0 license.
spellingShingle Original Research
Farias, Percio Augusto Mardini
Castro, Arnaldo Aguiar
Determination of Xanthine in the Presence of Hypoxanthine by Adsorptive Stripping Voltammetry at the Mercury Film Electrode
title Determination of Xanthine in the Presence of Hypoxanthine by Adsorptive Stripping Voltammetry at the Mercury Film Electrode
title_full Determination of Xanthine in the Presence of Hypoxanthine by Adsorptive Stripping Voltammetry at the Mercury Film Electrode
title_fullStr Determination of Xanthine in the Presence of Hypoxanthine by Adsorptive Stripping Voltammetry at the Mercury Film Electrode
title_full_unstemmed Determination of Xanthine in the Presence of Hypoxanthine by Adsorptive Stripping Voltammetry at the Mercury Film Electrode
title_short Determination of Xanthine in the Presence of Hypoxanthine by Adsorptive Stripping Voltammetry at the Mercury Film Electrode
title_sort determination of xanthine in the presence of hypoxanthine by adsorptive stripping voltammetry at the mercury film electrode
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4055419/
https://www.ncbi.nlm.nih.gov/pubmed/24940040
http://dx.doi.org/10.4137/ACI.S14712
work_keys_str_mv AT fariaspercioaugustomardini determinationofxanthineinthepresenceofhypoxanthinebyadsorptivestrippingvoltammetryatthemercuryfilmelectrode
AT castroarnaldoaguiar determinationofxanthineinthepresenceofhypoxanthinebyadsorptivestrippingvoltammetryatthemercuryfilmelectrode