Cargando…
Determination of Xanthine in the Presence of Hypoxanthine by Adsorptive Stripping Voltammetry at the Mercury Film Electrode
A stripping method for the determination of xanthine in the presence of hypoxanthine at the submicromolar concentration levels is described. The method is based on controlled adsorptive accumulation at the thin-film mercury electrode followed by a fast linear scan voltammetric measurement of the sur...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Libertas Academica
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4055419/ https://www.ncbi.nlm.nih.gov/pubmed/24940040 http://dx.doi.org/10.4137/ACI.S14712 |
_version_ | 1782320656446128128 |
---|---|
author | Farias, Percio Augusto Mardini Castro, Arnaldo Aguiar |
author_facet | Farias, Percio Augusto Mardini Castro, Arnaldo Aguiar |
author_sort | Farias, Percio Augusto Mardini |
collection | PubMed |
description | A stripping method for the determination of xanthine in the presence of hypoxanthine at the submicromolar concentration levels is described. The method is based on controlled adsorptive accumulation at the thin-film mercury electrode followed by a fast linear scan voltammetric measurement of the surface species. Optimum experimental conditions were found to be the use of 1.0 × 10(−3) mol L(−1) NaOH solution as supporting electrolyte, an accumulation potential of 0.00 V for xanthine and −0.50 V for hypoxanthine–copper, and a linear scan rate of 200 mV second(−1). The response of xanthine is linear over the concentration ranges of 20–140 ppb. For an accumulation time of 30 minutes, the detection limit was found to be 36 ppt (2.3 × 10(−10) mol L(−1)). Adequate conditions for measuring the xanthine in the presence of hypoxanthine, copper and other metals, uric acid, and other nitrogenated bases were also investigated. The utility of the method is demonstrated by the presence of xanthine associated with hypoxanthine, uric acid, nitrogenated bases, ATP, and ssDNA. |
format | Online Article Text |
id | pubmed-4055419 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Libertas Academica |
record_format | MEDLINE/PubMed |
spelling | pubmed-40554192014-06-17 Determination of Xanthine in the Presence of Hypoxanthine by Adsorptive Stripping Voltammetry at the Mercury Film Electrode Farias, Percio Augusto Mardini Castro, Arnaldo Aguiar Anal Chem Insights Original Research A stripping method for the determination of xanthine in the presence of hypoxanthine at the submicromolar concentration levels is described. The method is based on controlled adsorptive accumulation at the thin-film mercury electrode followed by a fast linear scan voltammetric measurement of the surface species. Optimum experimental conditions were found to be the use of 1.0 × 10(−3) mol L(−1) NaOH solution as supporting electrolyte, an accumulation potential of 0.00 V for xanthine and −0.50 V for hypoxanthine–copper, and a linear scan rate of 200 mV second(−1). The response of xanthine is linear over the concentration ranges of 20–140 ppb. For an accumulation time of 30 minutes, the detection limit was found to be 36 ppt (2.3 × 10(−10) mol L(−1)). Adequate conditions for measuring the xanthine in the presence of hypoxanthine, copper and other metals, uric acid, and other nitrogenated bases were also investigated. The utility of the method is demonstrated by the presence of xanthine associated with hypoxanthine, uric acid, nitrogenated bases, ATP, and ssDNA. Libertas Academica 2014-06-09 /pmc/articles/PMC4055419/ /pubmed/24940040 http://dx.doi.org/10.4137/ACI.S14712 Text en © 2014 the author(s), publisher and licensee Libertas Academica Ltd. This is an open access article published under the Creative Commons CC-BY-NC 3.0 license. |
spellingShingle | Original Research Farias, Percio Augusto Mardini Castro, Arnaldo Aguiar Determination of Xanthine in the Presence of Hypoxanthine by Adsorptive Stripping Voltammetry at the Mercury Film Electrode |
title | Determination of Xanthine in the Presence of Hypoxanthine by Adsorptive Stripping Voltammetry at the Mercury Film Electrode |
title_full | Determination of Xanthine in the Presence of Hypoxanthine by Adsorptive Stripping Voltammetry at the Mercury Film Electrode |
title_fullStr | Determination of Xanthine in the Presence of Hypoxanthine by Adsorptive Stripping Voltammetry at the Mercury Film Electrode |
title_full_unstemmed | Determination of Xanthine in the Presence of Hypoxanthine by Adsorptive Stripping Voltammetry at the Mercury Film Electrode |
title_short | Determination of Xanthine in the Presence of Hypoxanthine by Adsorptive Stripping Voltammetry at the Mercury Film Electrode |
title_sort | determination of xanthine in the presence of hypoxanthine by adsorptive stripping voltammetry at the mercury film electrode |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4055419/ https://www.ncbi.nlm.nih.gov/pubmed/24940040 http://dx.doi.org/10.4137/ACI.S14712 |
work_keys_str_mv | AT fariaspercioaugustomardini determinationofxanthineinthepresenceofhypoxanthinebyadsorptivestrippingvoltammetryatthemercuryfilmelectrode AT castroarnaldoaguiar determinationofxanthineinthepresenceofhypoxanthinebyadsorptivestrippingvoltammetryatthemercuryfilmelectrode |