Cargando…

Intra- and interobserver reliability of gray scale/dynamic range evaluation of ultrasonography using a standardized phantom

PURPOSE: To evaluate intra- and interobserver reliability of the gray scale/dynamic range of the phantom image evaluation of ultrasonography using a standardized phantom, and to assess the effect of interactive education on the reliability. METHODS: Three radiologists (a resident, and two board-cert...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Song, Choi, Joon-Il, Park, Michael Yong, Yeo, Dong Myung, Byun, Jae Young, Jung, Seung Eun, Rha, Sung Eun, Oh, Soon Nam, Lee, Young Joon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Ultrasound in Medicine 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4058983/
https://www.ncbi.nlm.nih.gov/pubmed/24936501
http://dx.doi.org/10.14366/usg.13021
_version_ 1782321198882881536
author Lee, Song
Choi, Joon-Il
Park, Michael Yong
Yeo, Dong Myung
Byun, Jae Young
Jung, Seung Eun
Rha, Sung Eun
Oh, Soon Nam
Lee, Young Joon
author_facet Lee, Song
Choi, Joon-Il
Park, Michael Yong
Yeo, Dong Myung
Byun, Jae Young
Jung, Seung Eun
Rha, Sung Eun
Oh, Soon Nam
Lee, Young Joon
author_sort Lee, Song
collection PubMed
description PURPOSE: To evaluate intra- and interobserver reliability of the gray scale/dynamic range of the phantom image evaluation of ultrasonography using a standardized phantom, and to assess the effect of interactive education on the reliability. METHODS: Three radiologists (a resident, and two board-certified radiologists with 2 and 7 years of experience in evaluating ultrasound phantom images) performed the gray scale/dynamic range test for an ultrasound machine using a standardized phantom. They scored the number of visible cylindrical structures of varying degrees of brightness and made a ‘pass or fail’ decision. First, they scored 49 phantom images twice from a 2010 survey with limited knowledge of phantom images. After this, the radiologists underwent two hours of interactive education for the phantom images and scored another 91 phantom images from a 2011 survey twice. Intra- and interobserver reliability before and after the interactive education session were analyzed using K analyses. RESULTS: Before education, the K-value for intraobserver reliability for the radiologist with 7 years of experience, 2 years of experience, and the resident was 0.386, 0.469, and 0.465, respectively. After education, the K-values were improved (0.823, 0.611, and 0.711, respectively). For interobserver reliability, the K-value was also better after the education for the 3 participants (0.067, 0.002, and 0.547 before education; 0.635, 0.667, and 0.616 after education, respectively). CONCLUSION: The intra- and interobserver reliability of the gray scale/dynamic range was fair to substantial. Interactive education can improve reliability. For more reliable results, double- checking of phantom images by multiple reviewers is recommended.
format Online
Article
Text
id pubmed-4058983
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Korean Society of Ultrasound in Medicine
record_format MEDLINE/PubMed
spelling pubmed-40589832014-06-16 Intra- and interobserver reliability of gray scale/dynamic range evaluation of ultrasonography using a standardized phantom Lee, Song Choi, Joon-Il Park, Michael Yong Yeo, Dong Myung Byun, Jae Young Jung, Seung Eun Rha, Sung Eun Oh, Soon Nam Lee, Young Joon Ultrasonography Original Article PURPOSE: To evaluate intra- and interobserver reliability of the gray scale/dynamic range of the phantom image evaluation of ultrasonography using a standardized phantom, and to assess the effect of interactive education on the reliability. METHODS: Three radiologists (a resident, and two board-certified radiologists with 2 and 7 years of experience in evaluating ultrasound phantom images) performed the gray scale/dynamic range test for an ultrasound machine using a standardized phantom. They scored the number of visible cylindrical structures of varying degrees of brightness and made a ‘pass or fail’ decision. First, they scored 49 phantom images twice from a 2010 survey with limited knowledge of phantom images. After this, the radiologists underwent two hours of interactive education for the phantom images and scored another 91 phantom images from a 2011 survey twice. Intra- and interobserver reliability before and after the interactive education session were analyzed using K analyses. RESULTS: Before education, the K-value for intraobserver reliability for the radiologist with 7 years of experience, 2 years of experience, and the resident was 0.386, 0.469, and 0.465, respectively. After education, the K-values were improved (0.823, 0.611, and 0.711, respectively). For interobserver reliability, the K-value was also better after the education for the 3 participants (0.067, 0.002, and 0.547 before education; 0.635, 0.667, and 0.616 after education, respectively). CONCLUSION: The intra- and interobserver reliability of the gray scale/dynamic range was fair to substantial. Interactive education can improve reliability. For more reliable results, double- checking of phantom images by multiple reviewers is recommended. Korean Society of Ultrasound in Medicine 2014-04 2014-02-26 /pmc/articles/PMC4058983/ /pubmed/24936501 http://dx.doi.org/10.14366/usg.13021 Text en Copyright © 2014 Korean Society of Ultrasound in Medicine (KSUM) This is an Open Access article distributed under the terms of the Creative Commons Attribution Non- Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non- commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lee, Song
Choi, Joon-Il
Park, Michael Yong
Yeo, Dong Myung
Byun, Jae Young
Jung, Seung Eun
Rha, Sung Eun
Oh, Soon Nam
Lee, Young Joon
Intra- and interobserver reliability of gray scale/dynamic range evaluation of ultrasonography using a standardized phantom
title Intra- and interobserver reliability of gray scale/dynamic range evaluation of ultrasonography using a standardized phantom
title_full Intra- and interobserver reliability of gray scale/dynamic range evaluation of ultrasonography using a standardized phantom
title_fullStr Intra- and interobserver reliability of gray scale/dynamic range evaluation of ultrasonography using a standardized phantom
title_full_unstemmed Intra- and interobserver reliability of gray scale/dynamic range evaluation of ultrasonography using a standardized phantom
title_short Intra- and interobserver reliability of gray scale/dynamic range evaluation of ultrasonography using a standardized phantom
title_sort intra- and interobserver reliability of gray scale/dynamic range evaluation of ultrasonography using a standardized phantom
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4058983/
https://www.ncbi.nlm.nih.gov/pubmed/24936501
http://dx.doi.org/10.14366/usg.13021
work_keys_str_mv AT leesong intraandinterobserverreliabilityofgrayscaledynamicrangeevaluationofultrasonographyusingastandardizedphantom
AT choijoonil intraandinterobserverreliabilityofgrayscaledynamicrangeevaluationofultrasonographyusingastandardizedphantom
AT parkmichaelyong intraandinterobserverreliabilityofgrayscaledynamicrangeevaluationofultrasonographyusingastandardizedphantom
AT yeodongmyung intraandinterobserverreliabilityofgrayscaledynamicrangeevaluationofultrasonographyusingastandardizedphantom
AT byunjaeyoung intraandinterobserverreliabilityofgrayscaledynamicrangeevaluationofultrasonographyusingastandardizedphantom
AT jungseungeun intraandinterobserverreliabilityofgrayscaledynamicrangeevaluationofultrasonographyusingastandardizedphantom
AT rhasungeun intraandinterobserverreliabilityofgrayscaledynamicrangeevaluationofultrasonographyusingastandardizedphantom
AT ohsoonnam intraandinterobserverreliabilityofgrayscaledynamicrangeevaluationofultrasonographyusingastandardizedphantom
AT leeyoungjoon intraandinterobserverreliabilityofgrayscaledynamicrangeevaluationofultrasonographyusingastandardizedphantom