Cargando…

Feasibility and efficacy of a remote real-time wireless ECG monitoring and stimulation system for management of ventricular arrhythmia in rabbits with myocardial infarction

The purpose of this study was to explore the feasibility of continuous remote monitoring, and the induction and termination of malignant ventricular arrhythmias (VAs) by a novel implantable electronic cardiovascular device (IECD) system in rabbits with myocardial infarction (MI). The IECD was implan...

Descripción completa

Detalles Bibliográficos
Autores principales: ZHOU, ZHI-WEN, GOU, KAI, LUO, ZHANG-YUAN, LI, WEI, ZHANG, WEN-ZAN, LI, YI-GANG
Formato: Online Artículo Texto
Lenguaje:English
Publicado: D.A. Spandidos 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4061215/
https://www.ncbi.nlm.nih.gov/pubmed/24944622
http://dx.doi.org/10.3892/etm.2014.1693
_version_ 1782321472947093504
author ZHOU, ZHI-WEN
GOU, KAI
LUO, ZHANG-YUAN
LI, WEI
ZHANG, WEN-ZAN
LI, YI-GANG
author_facet ZHOU, ZHI-WEN
GOU, KAI
LUO, ZHANG-YUAN
LI, WEI
ZHANG, WEN-ZAN
LI, YI-GANG
author_sort ZHOU, ZHI-WEN
collection PubMed
description The purpose of this study was to explore the feasibility of continuous remote monitoring, and the induction and termination of malignant ventricular arrhythmias (VAs) by a novel implantable electronic cardiovascular device (IECD) system in rabbits with myocardial infarction (MI). The IECD was implanted and MI was induced by ligation of the left anterior descending coronary artery in 20 adult rabbits. Internet-based remote electrocardiogram (ECG) monitoring and ventricular stimulation were conducted in remote locations with internet access. The voltage amplitudes of the stimulation signals were recorded synchronously by remote and surface ECG. Programmed stimulation with regular stimuli and regular stimuli with an added extra stimulus were performed prior to and following the MI surgery to induce and terminate VAs. IECD implantation and MI surgery, as well as qualified remote and bidirectional signal communications between the implanted IECD and extracorporeal system, were successfully achieved in 18 rabbits. The voltage of the stimulation signals recorded by the remote and surface ECGs showed a good correlation with the stimulation current (remote ECG, r=0.972 and surface ECG, r=0.988; P<0.001). Sustained ventricular tachycardia (VT) was induced in five rabbits (5/20, 25%) prior to MI induction and in 12 rabbits (12/16, 75%) following MI induction. Of the 17 induced VTs, 16 were successfully terminated by remote ventricular stimulation. The novel IECD system provides qualified remote wireless ECG monitoring and possesses the potential to induce and terminate VAs by remote ventricular pacing in this rabbit model of MI. Thus, this model of MI may be used to test the efficacy of novel drugs and devices for the management of VAs.
format Online
Article
Text
id pubmed-4061215
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher D.A. Spandidos
record_format MEDLINE/PubMed
spelling pubmed-40612152014-06-18 Feasibility and efficacy of a remote real-time wireless ECG monitoring and stimulation system for management of ventricular arrhythmia in rabbits with myocardial infarction ZHOU, ZHI-WEN GOU, KAI LUO, ZHANG-YUAN LI, WEI ZHANG, WEN-ZAN LI, YI-GANG Exp Ther Med Articles The purpose of this study was to explore the feasibility of continuous remote monitoring, and the induction and termination of malignant ventricular arrhythmias (VAs) by a novel implantable electronic cardiovascular device (IECD) system in rabbits with myocardial infarction (MI). The IECD was implanted and MI was induced by ligation of the left anterior descending coronary artery in 20 adult rabbits. Internet-based remote electrocardiogram (ECG) monitoring and ventricular stimulation were conducted in remote locations with internet access. The voltage amplitudes of the stimulation signals were recorded synchronously by remote and surface ECG. Programmed stimulation with regular stimuli and regular stimuli with an added extra stimulus were performed prior to and following the MI surgery to induce and terminate VAs. IECD implantation and MI surgery, as well as qualified remote and bidirectional signal communications between the implanted IECD and extracorporeal system, were successfully achieved in 18 rabbits. The voltage of the stimulation signals recorded by the remote and surface ECGs showed a good correlation with the stimulation current (remote ECG, r=0.972 and surface ECG, r=0.988; P<0.001). Sustained ventricular tachycardia (VT) was induced in five rabbits (5/20, 25%) prior to MI induction and in 12 rabbits (12/16, 75%) following MI induction. Of the 17 induced VTs, 16 were successfully terminated by remote ventricular stimulation. The novel IECD system provides qualified remote wireless ECG monitoring and possesses the potential to induce and terminate VAs by remote ventricular pacing in this rabbit model of MI. Thus, this model of MI may be used to test the efficacy of novel drugs and devices for the management of VAs. D.A. Spandidos 2014-07 2014-04-25 /pmc/articles/PMC4061215/ /pubmed/24944622 http://dx.doi.org/10.3892/etm.2014.1693 Text en Copyright © 2014, Spandidos Publications http://creativecommons.org/licenses/by/3.0 This is an open-access article licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported License. The article may be redistributed, reproduced, and reused for non-commercial purposes, provided the original source is properly cited.
spellingShingle Articles
ZHOU, ZHI-WEN
GOU, KAI
LUO, ZHANG-YUAN
LI, WEI
ZHANG, WEN-ZAN
LI, YI-GANG
Feasibility and efficacy of a remote real-time wireless ECG monitoring and stimulation system for management of ventricular arrhythmia in rabbits with myocardial infarction
title Feasibility and efficacy of a remote real-time wireless ECG monitoring and stimulation system for management of ventricular arrhythmia in rabbits with myocardial infarction
title_full Feasibility and efficacy of a remote real-time wireless ECG monitoring and stimulation system for management of ventricular arrhythmia in rabbits with myocardial infarction
title_fullStr Feasibility and efficacy of a remote real-time wireless ECG monitoring and stimulation system for management of ventricular arrhythmia in rabbits with myocardial infarction
title_full_unstemmed Feasibility and efficacy of a remote real-time wireless ECG monitoring and stimulation system for management of ventricular arrhythmia in rabbits with myocardial infarction
title_short Feasibility and efficacy of a remote real-time wireless ECG monitoring and stimulation system for management of ventricular arrhythmia in rabbits with myocardial infarction
title_sort feasibility and efficacy of a remote real-time wireless ecg monitoring and stimulation system for management of ventricular arrhythmia in rabbits with myocardial infarction
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4061215/
https://www.ncbi.nlm.nih.gov/pubmed/24944622
http://dx.doi.org/10.3892/etm.2014.1693
work_keys_str_mv AT zhouzhiwen feasibilityandefficacyofaremoterealtimewirelessecgmonitoringandstimulationsystemformanagementofventriculararrhythmiainrabbitswithmyocardialinfarction
AT goukai feasibilityandefficacyofaremoterealtimewirelessecgmonitoringandstimulationsystemformanagementofventriculararrhythmiainrabbitswithmyocardialinfarction
AT luozhangyuan feasibilityandefficacyofaremoterealtimewirelessecgmonitoringandstimulationsystemformanagementofventriculararrhythmiainrabbitswithmyocardialinfarction
AT liwei feasibilityandefficacyofaremoterealtimewirelessecgmonitoringandstimulationsystemformanagementofventriculararrhythmiainrabbitswithmyocardialinfarction
AT zhangwenzan feasibilityandefficacyofaremoterealtimewirelessecgmonitoringandstimulationsystemformanagementofventriculararrhythmiainrabbitswithmyocardialinfarction
AT liyigang feasibilityandefficacyofaremoterealtimewirelessecgmonitoringandstimulationsystemformanagementofventriculararrhythmiainrabbitswithmyocardialinfarction