Cargando…

Spontaneous fracture of an implanted posterior chamber polyimide intraocular lens haptic: A case report

A 57-year-old male patient visited our clinic for decreased visual acuity in the right eye for 10 days. He denied any trauma history, but recalled that the symptom developed after straining. He had undergone uncomplicated phacoemulsification and posterior chamber intraocular lens (IOL) implantation...

Descripción completa

Detalles Bibliográficos
Autores principales: Kang, Haemin, Han, Kyung Eun, Kim, Tae-im, Kim, Eung Kweon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4061679/
https://www.ncbi.nlm.nih.gov/pubmed/23619497
http://dx.doi.org/10.4103/0301-4738.111195
_version_ 1782321536393281536
author Kang, Haemin
Han, Kyung Eun
Kim, Tae-im
Kim, Eung Kweon
author_facet Kang, Haemin
Han, Kyung Eun
Kim, Tae-im
Kim, Eung Kweon
author_sort Kang, Haemin
collection PubMed
description A 57-year-old male patient visited our clinic for decreased visual acuity in the right eye for 10 days. He denied any trauma history, but recalled that the symptom developed after straining. He had undergone uncomplicated phacoemulsification and posterior chamber intraocular lens (IOL) implantation in the bag of the right eye 11 years ago. The IOL was a three-piece silicone polyimide-haptics design. On slit-lamp examination, the IOL optic and proximal part of nasal fractured haptic were found in the anterior chamber. The distal part of fractured haptic was observed in the capsular bag. He underwent IOL exchange. The fracture site of the haptic was near the optic–haptic junction. This is the unique case report of a spontaneous fracture of an implanted posterior chamber polyimide IOL haptic, which implies the possibility of IOL haptic fracture in various haptic materials.
format Online
Article
Text
id pubmed-4061679
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-40616792014-06-19 Spontaneous fracture of an implanted posterior chamber polyimide intraocular lens haptic: A case report Kang, Haemin Han, Kyung Eun Kim, Tae-im Kim, Eung Kweon Indian J Ophthalmol Brief Communications A 57-year-old male patient visited our clinic for decreased visual acuity in the right eye for 10 days. He denied any trauma history, but recalled that the symptom developed after straining. He had undergone uncomplicated phacoemulsification and posterior chamber intraocular lens (IOL) implantation in the bag of the right eye 11 years ago. The IOL was a three-piece silicone polyimide-haptics design. On slit-lamp examination, the IOL optic and proximal part of nasal fractured haptic were found in the anterior chamber. The distal part of fractured haptic was observed in the capsular bag. He underwent IOL exchange. The fracture site of the haptic was near the optic–haptic junction. This is the unique case report of a spontaneous fracture of an implanted posterior chamber polyimide IOL haptic, which implies the possibility of IOL haptic fracture in various haptic materials. Medknow Publications & Media Pvt Ltd 2014-03 /pmc/articles/PMC4061679/ /pubmed/23619497 http://dx.doi.org/10.4103/0301-4738.111195 Text en Copyright: © Indian Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Brief Communications
Kang, Haemin
Han, Kyung Eun
Kim, Tae-im
Kim, Eung Kweon
Spontaneous fracture of an implanted posterior chamber polyimide intraocular lens haptic: A case report
title Spontaneous fracture of an implanted posterior chamber polyimide intraocular lens haptic: A case report
title_full Spontaneous fracture of an implanted posterior chamber polyimide intraocular lens haptic: A case report
title_fullStr Spontaneous fracture of an implanted posterior chamber polyimide intraocular lens haptic: A case report
title_full_unstemmed Spontaneous fracture of an implanted posterior chamber polyimide intraocular lens haptic: A case report
title_short Spontaneous fracture of an implanted posterior chamber polyimide intraocular lens haptic: A case report
title_sort spontaneous fracture of an implanted posterior chamber polyimide intraocular lens haptic: a case report
topic Brief Communications
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4061679/
https://www.ncbi.nlm.nih.gov/pubmed/23619497
http://dx.doi.org/10.4103/0301-4738.111195
work_keys_str_mv AT kanghaemin spontaneousfractureofanimplantedposteriorchamberpolyimideintraocularlenshapticacasereport
AT hankyungeun spontaneousfractureofanimplantedposteriorchamberpolyimideintraocularlenshapticacasereport
AT kimtaeim spontaneousfractureofanimplantedposteriorchamberpolyimideintraocularlenshapticacasereport
AT kimeungkweon spontaneousfractureofanimplantedposteriorchamberpolyimideintraocularlenshapticacasereport