Novel Calibration Algorithm for a Three-Axis Strapdown Magnetometer

A complete error calibration model with 12 independent parameters is established by analyzing the three-axis magnetometer error mechanism. The said model conforms to an ellipsoid restriction, the parameters of the ellipsoid equation are estimated, and the ellipsoid coefficient matrix is derived. How...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Yan Xia, Li, Xi Sheng, Zhang, Xiao Juan, Feng, Yi Bo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4063011/
https://www.ncbi.nlm.nih.gov/pubmed/24831110
http://dx.doi.org/10.3390/s140508485
_version_ 1782321728514424832
author Liu, Yan Xia
Li, Xi Sheng
Zhang, Xiao Juan
Feng, Yi Bo
author_facet Liu, Yan Xia
Li, Xi Sheng
Zhang, Xiao Juan
Feng, Yi Bo
author_sort Liu, Yan Xia
collection PubMed
description A complete error calibration model with 12 independent parameters is established by analyzing the three-axis magnetometer error mechanism. The said model conforms to an ellipsoid restriction, the parameters of the ellipsoid equation are estimated, and the ellipsoid coefficient matrix is derived. However, the calibration matrix cannot be determined completely, as there are fewer ellipsoid parameters than calibration model parameters. Mathematically, the calibration matrix derived from the ellipsoid coefficient matrix by a different matrix decomposition method is not unique, and there exists an unknown rotation matrix R between them. This paper puts forward a constant intersection angle method (angles between the geomagnetic field and gravitational field are fixed) to estimate R. The Tikhonov method is adopted to solve the problem that rounding errors or other errors may seriously affect the calculation results of R when the condition number of the matrix is very large. The geomagnetic field vector and heading error are further corrected by R. The constant intersection angle method is convenient and practical, as it is free from any additional calibration procedure or coordinate transformation. In addition, the simulation experiment indicates that the heading error declines from ±1° calibrated by classical ellipsoid fitting to ±0.2° calibrated by a constant intersection angle method, and the signal-to-noise ratio is 50 dB. The actual experiment exhibits that the heading error is further corrected from ±0.8° calibrated by the classical ellipsoid fitting to ±0.3° calibrated by a constant intersection angle method.
format Online
Article
Text
id pubmed-4063011
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-40630112014-06-19 Novel Calibration Algorithm for a Three-Axis Strapdown Magnetometer Liu, Yan Xia Li, Xi Sheng Zhang, Xiao Juan Feng, Yi Bo Sensors (Basel) Article A complete error calibration model with 12 independent parameters is established by analyzing the three-axis magnetometer error mechanism. The said model conforms to an ellipsoid restriction, the parameters of the ellipsoid equation are estimated, and the ellipsoid coefficient matrix is derived. However, the calibration matrix cannot be determined completely, as there are fewer ellipsoid parameters than calibration model parameters. Mathematically, the calibration matrix derived from the ellipsoid coefficient matrix by a different matrix decomposition method is not unique, and there exists an unknown rotation matrix R between them. This paper puts forward a constant intersection angle method (angles between the geomagnetic field and gravitational field are fixed) to estimate R. The Tikhonov method is adopted to solve the problem that rounding errors or other errors may seriously affect the calculation results of R when the condition number of the matrix is very large. The geomagnetic field vector and heading error are further corrected by R. The constant intersection angle method is convenient and practical, as it is free from any additional calibration procedure or coordinate transformation. In addition, the simulation experiment indicates that the heading error declines from ±1° calibrated by classical ellipsoid fitting to ±0.2° calibrated by a constant intersection angle method, and the signal-to-noise ratio is 50 dB. The actual experiment exhibits that the heading error is further corrected from ±0.8° calibrated by the classical ellipsoid fitting to ±0.3° calibrated by a constant intersection angle method. Molecular Diversity Preservation International (MDPI) 2014-05-14 /pmc/articles/PMC4063011/ /pubmed/24831110 http://dx.doi.org/10.3390/s140508485 Text en © 2014 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Liu, Yan Xia
Li, Xi Sheng
Zhang, Xiao Juan
Feng, Yi Bo
Novel Calibration Algorithm for a Three-Axis Strapdown Magnetometer
title Novel Calibration Algorithm for a Three-Axis Strapdown Magnetometer
title_full Novel Calibration Algorithm for a Three-Axis Strapdown Magnetometer
title_fullStr Novel Calibration Algorithm for a Three-Axis Strapdown Magnetometer
title_full_unstemmed Novel Calibration Algorithm for a Three-Axis Strapdown Magnetometer
title_short Novel Calibration Algorithm for a Three-Axis Strapdown Magnetometer
title_sort novel calibration algorithm for a three-axis strapdown magnetometer
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4063011/
https://www.ncbi.nlm.nih.gov/pubmed/24831110
http://dx.doi.org/10.3390/s140508485
work_keys_str_mv AT liuyanxia novelcalibrationalgorithmforathreeaxisstrapdownmagnetometer
AT lixisheng novelcalibrationalgorithmforathreeaxisstrapdownmagnetometer
AT zhangxiaojuan novelcalibrationalgorithmforathreeaxisstrapdownmagnetometer
AT fengyibo novelcalibrationalgorithmforathreeaxisstrapdownmagnetometer