Novel Calibration Algorithm for a Three-Axis Strapdown Magnetometer
A complete error calibration model with 12 independent parameters is established by analyzing the three-axis magnetometer error mechanism. The said model conforms to an ellipsoid restriction, the parameters of the ellipsoid equation are estimated, and the ellipsoid coefficient matrix is derived. How...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Molecular Diversity Preservation International (MDPI)
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4063011/ https://www.ncbi.nlm.nih.gov/pubmed/24831110 http://dx.doi.org/10.3390/s140508485 |
_version_ | 1782321728514424832 |
---|---|
author | Liu, Yan Xia Li, Xi Sheng Zhang, Xiao Juan Feng, Yi Bo |
author_facet | Liu, Yan Xia Li, Xi Sheng Zhang, Xiao Juan Feng, Yi Bo |
author_sort | Liu, Yan Xia |
collection | PubMed |
description | A complete error calibration model with 12 independent parameters is established by analyzing the three-axis magnetometer error mechanism. The said model conforms to an ellipsoid restriction, the parameters of the ellipsoid equation are estimated, and the ellipsoid coefficient matrix is derived. However, the calibration matrix cannot be determined completely, as there are fewer ellipsoid parameters than calibration model parameters. Mathematically, the calibration matrix derived from the ellipsoid coefficient matrix by a different matrix decomposition method is not unique, and there exists an unknown rotation matrix R between them. This paper puts forward a constant intersection angle method (angles between the geomagnetic field and gravitational field are fixed) to estimate R. The Tikhonov method is adopted to solve the problem that rounding errors or other errors may seriously affect the calculation results of R when the condition number of the matrix is very large. The geomagnetic field vector and heading error are further corrected by R. The constant intersection angle method is convenient and practical, as it is free from any additional calibration procedure or coordinate transformation. In addition, the simulation experiment indicates that the heading error declines from ±1° calibrated by classical ellipsoid fitting to ±0.2° calibrated by a constant intersection angle method, and the signal-to-noise ratio is 50 dB. The actual experiment exhibits that the heading error is further corrected from ±0.8° calibrated by the classical ellipsoid fitting to ±0.3° calibrated by a constant intersection angle method. |
format | Online Article Text |
id | pubmed-4063011 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Molecular Diversity Preservation International (MDPI) |
record_format | MEDLINE/PubMed |
spelling | pubmed-40630112014-06-19 Novel Calibration Algorithm for a Three-Axis Strapdown Magnetometer Liu, Yan Xia Li, Xi Sheng Zhang, Xiao Juan Feng, Yi Bo Sensors (Basel) Article A complete error calibration model with 12 independent parameters is established by analyzing the three-axis magnetometer error mechanism. The said model conforms to an ellipsoid restriction, the parameters of the ellipsoid equation are estimated, and the ellipsoid coefficient matrix is derived. However, the calibration matrix cannot be determined completely, as there are fewer ellipsoid parameters than calibration model parameters. Mathematically, the calibration matrix derived from the ellipsoid coefficient matrix by a different matrix decomposition method is not unique, and there exists an unknown rotation matrix R between them. This paper puts forward a constant intersection angle method (angles between the geomagnetic field and gravitational field are fixed) to estimate R. The Tikhonov method is adopted to solve the problem that rounding errors or other errors may seriously affect the calculation results of R when the condition number of the matrix is very large. The geomagnetic field vector and heading error are further corrected by R. The constant intersection angle method is convenient and practical, as it is free from any additional calibration procedure or coordinate transformation. In addition, the simulation experiment indicates that the heading error declines from ±1° calibrated by classical ellipsoid fitting to ±0.2° calibrated by a constant intersection angle method, and the signal-to-noise ratio is 50 dB. The actual experiment exhibits that the heading error is further corrected from ±0.8° calibrated by the classical ellipsoid fitting to ±0.3° calibrated by a constant intersection angle method. Molecular Diversity Preservation International (MDPI) 2014-05-14 /pmc/articles/PMC4063011/ /pubmed/24831110 http://dx.doi.org/10.3390/s140508485 Text en © 2014 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Liu, Yan Xia Li, Xi Sheng Zhang, Xiao Juan Feng, Yi Bo Novel Calibration Algorithm for a Three-Axis Strapdown Magnetometer |
title | Novel Calibration Algorithm for a Three-Axis Strapdown Magnetometer |
title_full | Novel Calibration Algorithm for a Three-Axis Strapdown Magnetometer |
title_fullStr | Novel Calibration Algorithm for a Three-Axis Strapdown Magnetometer |
title_full_unstemmed | Novel Calibration Algorithm for a Three-Axis Strapdown Magnetometer |
title_short | Novel Calibration Algorithm for a Three-Axis Strapdown Magnetometer |
title_sort | novel calibration algorithm for a three-axis strapdown magnetometer |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4063011/ https://www.ncbi.nlm.nih.gov/pubmed/24831110 http://dx.doi.org/10.3390/s140508485 |
work_keys_str_mv | AT liuyanxia novelcalibrationalgorithmforathreeaxisstrapdownmagnetometer AT lixisheng novelcalibrationalgorithmforathreeaxisstrapdownmagnetometer AT zhangxiaojuan novelcalibrationalgorithmforathreeaxisstrapdownmagnetometer AT fengyibo novelcalibrationalgorithmforathreeaxisstrapdownmagnetometer |