Cargando…

A round robin approach to the analysis of bisphenol a (BPA) in human blood samples

BACKGROUND: Human exposure to bisphenol A (BPA) is ubiquitous, yet there are concerns about whether BPA can be measured in human blood. This Round Robin was designed to address this concern through three goals: 1) to identify collection materials, reagents and detection apparatuses that do not contr...

Descripción completa

Detalles Bibliográficos
Autores principales: Vandenberg, Laura N, Gerona, Roy R, Kannan, Kurunthachalam, Taylor, Julia A, van Breemen, Richard B, Dickenson, Carrie A, Liao, Chunyang, Yuan, Yang, Newbold, Retha R, Padmanabhan, Vasantha, vom Saal, Frederick S, Woodruff, Tracey J
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4066311/
https://www.ncbi.nlm.nih.gov/pubmed/24690217
http://dx.doi.org/10.1186/1476-069X-13-25
_version_ 1782322166213115904
author Vandenberg, Laura N
Gerona, Roy R
Kannan, Kurunthachalam
Taylor, Julia A
van Breemen, Richard B
Dickenson, Carrie A
Liao, Chunyang
Yuan, Yang
Newbold, Retha R
Padmanabhan, Vasantha
vom Saal, Frederick S
Woodruff, Tracey J
author_facet Vandenberg, Laura N
Gerona, Roy R
Kannan, Kurunthachalam
Taylor, Julia A
van Breemen, Richard B
Dickenson, Carrie A
Liao, Chunyang
Yuan, Yang
Newbold, Retha R
Padmanabhan, Vasantha
vom Saal, Frederick S
Woodruff, Tracey J
author_sort Vandenberg, Laura N
collection PubMed
description BACKGROUND: Human exposure to bisphenol A (BPA) is ubiquitous, yet there are concerns about whether BPA can be measured in human blood. This Round Robin was designed to address this concern through three goals: 1) to identify collection materials, reagents and detection apparatuses that do not contribute BPA to serum; 2) to identify sensitive and precise methods to accurately measure unconjugated BPA (uBPA) and BPA-glucuronide (BPA-G), a metabolite, in serum; and 3) to evaluate whether inadvertent hydrolysis of BPA-G occurs during sample handling and processing. METHODS: Four laboratories participated in this Round Robin. Laboratories screened materials to identify BPA contamination in collection and analysis materials. Serum was spiked with concentrations of uBPA and/or BPA-G ranging from 0.09-19.5 (uBPA) and 0.5-32 (BPA-G) ng/mL. Additional samples were preserved unspiked as ‘environmental’ samples. Blinded samples were provided to laboratories that used LC/MSMS to simultaneously quantify uBPA and BPA-G. To determine whether inadvertent hydrolysis of BPA metabolites occurred, samples spiked with only BPA-G were analyzed for the presence of uBPA. Finally, three laboratories compared direct and indirect methods of quantifying BPA-G. RESULTS: We identified collection materials and reagents that did not introduce BPA contamination. In the blinded spiked sample analysis, all laboratories were able to distinguish low from high values of uBPA and BPA-G, for the whole spiked sample range and for those samples spiked with the three lowest concentrations (0.5-3.1 ng/ml). By completion of the Round Robin, three laboratories had verified methods for the analysis of uBPA and two verified for the analysis of BPA-G (verification determined by: 4 of 5 samples within 20% of spiked concentrations). In the analysis of BPA-G only spiked samples, all laboratories reported BPA-G was the majority of BPA detected (92.2 – 100%). Finally, laboratories were more likely to be verified using direct methods than indirect ones using enzymatic hydrolysis. CONCLUSIONS: Sensitive and accurate methods for the direct quantification of uBPA and BPA-G were developed in multiple laboratories and can be used for the analysis of human serum samples. BPA contamination can be controlled during sample collection and inadvertent hydrolysis of BPA conjugates can be avoided during sample handling.
format Online
Article
Text
id pubmed-4066311
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-40663112014-06-24 A round robin approach to the analysis of bisphenol a (BPA) in human blood samples Vandenberg, Laura N Gerona, Roy R Kannan, Kurunthachalam Taylor, Julia A van Breemen, Richard B Dickenson, Carrie A Liao, Chunyang Yuan, Yang Newbold, Retha R Padmanabhan, Vasantha vom Saal, Frederick S Woodruff, Tracey J Environ Health Research BACKGROUND: Human exposure to bisphenol A (BPA) is ubiquitous, yet there are concerns about whether BPA can be measured in human blood. This Round Robin was designed to address this concern through three goals: 1) to identify collection materials, reagents and detection apparatuses that do not contribute BPA to serum; 2) to identify sensitive and precise methods to accurately measure unconjugated BPA (uBPA) and BPA-glucuronide (BPA-G), a metabolite, in serum; and 3) to evaluate whether inadvertent hydrolysis of BPA-G occurs during sample handling and processing. METHODS: Four laboratories participated in this Round Robin. Laboratories screened materials to identify BPA contamination in collection and analysis materials. Serum was spiked with concentrations of uBPA and/or BPA-G ranging from 0.09-19.5 (uBPA) and 0.5-32 (BPA-G) ng/mL. Additional samples were preserved unspiked as ‘environmental’ samples. Blinded samples were provided to laboratories that used LC/MSMS to simultaneously quantify uBPA and BPA-G. To determine whether inadvertent hydrolysis of BPA metabolites occurred, samples spiked with only BPA-G were analyzed for the presence of uBPA. Finally, three laboratories compared direct and indirect methods of quantifying BPA-G. RESULTS: We identified collection materials and reagents that did not introduce BPA contamination. In the blinded spiked sample analysis, all laboratories were able to distinguish low from high values of uBPA and BPA-G, for the whole spiked sample range and for those samples spiked with the three lowest concentrations (0.5-3.1 ng/ml). By completion of the Round Robin, three laboratories had verified methods for the analysis of uBPA and two verified for the analysis of BPA-G (verification determined by: 4 of 5 samples within 20% of spiked concentrations). In the analysis of BPA-G only spiked samples, all laboratories reported BPA-G was the majority of BPA detected (92.2 – 100%). Finally, laboratories were more likely to be verified using direct methods than indirect ones using enzymatic hydrolysis. CONCLUSIONS: Sensitive and accurate methods for the direct quantification of uBPA and BPA-G were developed in multiple laboratories and can be used for the analysis of human serum samples. BPA contamination can be controlled during sample collection and inadvertent hydrolysis of BPA conjugates can be avoided during sample handling. BioMed Central 2014-04-01 /pmc/articles/PMC4066311/ /pubmed/24690217 http://dx.doi.org/10.1186/1476-069X-13-25 Text en Copyright © 2014 Vandenberg et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Vandenberg, Laura N
Gerona, Roy R
Kannan, Kurunthachalam
Taylor, Julia A
van Breemen, Richard B
Dickenson, Carrie A
Liao, Chunyang
Yuan, Yang
Newbold, Retha R
Padmanabhan, Vasantha
vom Saal, Frederick S
Woodruff, Tracey J
A round robin approach to the analysis of bisphenol a (BPA) in human blood samples
title A round robin approach to the analysis of bisphenol a (BPA) in human blood samples
title_full A round robin approach to the analysis of bisphenol a (BPA) in human blood samples
title_fullStr A round robin approach to the analysis of bisphenol a (BPA) in human blood samples
title_full_unstemmed A round robin approach to the analysis of bisphenol a (BPA) in human blood samples
title_short A round robin approach to the analysis of bisphenol a (BPA) in human blood samples
title_sort round robin approach to the analysis of bisphenol a (bpa) in human blood samples
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4066311/
https://www.ncbi.nlm.nih.gov/pubmed/24690217
http://dx.doi.org/10.1186/1476-069X-13-25
work_keys_str_mv AT vandenberglauran aroundrobinapproachtotheanalysisofbisphenolabpainhumanbloodsamples
AT geronaroyr aroundrobinapproachtotheanalysisofbisphenolabpainhumanbloodsamples
AT kannankurunthachalam aroundrobinapproachtotheanalysisofbisphenolabpainhumanbloodsamples
AT taylorjuliaa aroundrobinapproachtotheanalysisofbisphenolabpainhumanbloodsamples
AT vanbreemenrichardb aroundrobinapproachtotheanalysisofbisphenolabpainhumanbloodsamples
AT dickensoncarriea aroundrobinapproachtotheanalysisofbisphenolabpainhumanbloodsamples
AT liaochunyang aroundrobinapproachtotheanalysisofbisphenolabpainhumanbloodsamples
AT yuanyang aroundrobinapproachtotheanalysisofbisphenolabpainhumanbloodsamples
AT newboldrethar aroundrobinapproachtotheanalysisofbisphenolabpainhumanbloodsamples
AT padmanabhanvasantha aroundrobinapproachtotheanalysisofbisphenolabpainhumanbloodsamples
AT vomsaalfredericks aroundrobinapproachtotheanalysisofbisphenolabpainhumanbloodsamples
AT woodrufftraceyj aroundrobinapproachtotheanalysisofbisphenolabpainhumanbloodsamples
AT vandenberglauran roundrobinapproachtotheanalysisofbisphenolabpainhumanbloodsamples
AT geronaroyr roundrobinapproachtotheanalysisofbisphenolabpainhumanbloodsamples
AT kannankurunthachalam roundrobinapproachtotheanalysisofbisphenolabpainhumanbloodsamples
AT taylorjuliaa roundrobinapproachtotheanalysisofbisphenolabpainhumanbloodsamples
AT vanbreemenrichardb roundrobinapproachtotheanalysisofbisphenolabpainhumanbloodsamples
AT dickensoncarriea roundrobinapproachtotheanalysisofbisphenolabpainhumanbloodsamples
AT liaochunyang roundrobinapproachtotheanalysisofbisphenolabpainhumanbloodsamples
AT yuanyang roundrobinapproachtotheanalysisofbisphenolabpainhumanbloodsamples
AT newboldrethar roundrobinapproachtotheanalysisofbisphenolabpainhumanbloodsamples
AT padmanabhanvasantha roundrobinapproachtotheanalysisofbisphenolabpainhumanbloodsamples
AT vomsaalfredericks roundrobinapproachtotheanalysisofbisphenolabpainhumanbloodsamples
AT woodrufftraceyj roundrobinapproachtotheanalysisofbisphenolabpainhumanbloodsamples