Noninvasive method for retrieval of broken dental implant abutment screw

Dental implants made of titanium for replacement of missing teeth are widely used because of ease of technical procedure and high success rate, but are not free of complications and may fail. Fracturing of the prosthetic screw continues to be a problem in restorative practice and great challenge to...

Descripción completa

Detalles Bibliográficos
Autores principales: Gooty, Jagadish Reddy, Palakuru, Sunil Kumar, Guntakalla, Vikram Reddy, Nera, Mahipal
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4067798/
https://www.ncbi.nlm.nih.gov/pubmed/24963261
http://dx.doi.org/10.4103/0976-237X.132382
_version_ 1782322337594474496
author Gooty, Jagadish Reddy
Palakuru, Sunil Kumar
Guntakalla, Vikram Reddy
Nera, Mahipal
author_facet Gooty, Jagadish Reddy
Palakuru, Sunil Kumar
Guntakalla, Vikram Reddy
Nera, Mahipal
author_sort Gooty, Jagadish Reddy
collection PubMed
description Dental implants made of titanium for replacement of missing teeth are widely used because of ease of technical procedure and high success rate, but are not free of complications and may fail. Fracturing of the prosthetic screw continues to be a problem in restorative practice and great challenge to remove the fractured screw conservatively. This case report describes and demonstrates the technique of using an ultrasonic scaler in the removal of the fracture screw fragment as a noninvasive method without damaging the hex of implants.
format Online
Article
Text
id pubmed-4067798
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-40677982014-06-24 Noninvasive method for retrieval of broken dental implant abutment screw Gooty, Jagadish Reddy Palakuru, Sunil Kumar Guntakalla, Vikram Reddy Nera, Mahipal Contemp Clin Dent Case Report Dental implants made of titanium for replacement of missing teeth are widely used because of ease of technical procedure and high success rate, but are not free of complications and may fail. Fracturing of the prosthetic screw continues to be a problem in restorative practice and great challenge to remove the fractured screw conservatively. This case report describes and demonstrates the technique of using an ultrasonic scaler in the removal of the fracture screw fragment as a noninvasive method without damaging the hex of implants. Medknow Publications & Media Pvt Ltd 2014 /pmc/articles/PMC4067798/ /pubmed/24963261 http://dx.doi.org/10.4103/0976-237X.132382 Text en Copyright: © Contemporary Clinical Dentistry http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Gooty, Jagadish Reddy
Palakuru, Sunil Kumar
Guntakalla, Vikram Reddy
Nera, Mahipal
Noninvasive method for retrieval of broken dental implant abutment screw
title Noninvasive method for retrieval of broken dental implant abutment screw
title_full Noninvasive method for retrieval of broken dental implant abutment screw
title_fullStr Noninvasive method for retrieval of broken dental implant abutment screw
title_full_unstemmed Noninvasive method for retrieval of broken dental implant abutment screw
title_short Noninvasive method for retrieval of broken dental implant abutment screw
title_sort noninvasive method for retrieval of broken dental implant abutment screw
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4067798/
https://www.ncbi.nlm.nih.gov/pubmed/24963261
http://dx.doi.org/10.4103/0976-237X.132382
work_keys_str_mv AT gootyjagadishreddy noninvasivemethodforretrievalofbrokendentalimplantabutmentscrew
AT palakurusunilkumar noninvasivemethodforretrievalofbrokendentalimplantabutmentscrew
AT guntakallavikramreddy noninvasivemethodforretrievalofbrokendentalimplantabutmentscrew
AT neramahipal noninvasivemethodforretrievalofbrokendentalimplantabutmentscrew