Developments in optics and performance at BL13-XALOC, the macromolecular crystallography beamline at the Alba Synchrotron
BL13-XALOC is currently the only macromolecular crystallography beamline at the 3 GeV ALBA synchrotron near Barcelona, Spain. The optics design is based on an in-vacuum undulator, a Si(111) channel-cut crystal monochromator and a pair of KB mirrors. It allows three main operation modes: a focused co...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Union of Crystallography
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4073956/ https://www.ncbi.nlm.nih.gov/pubmed/24971961 http://dx.doi.org/10.1107/S160057751400825X |
_version_ | 1782323161494192128 |
---|---|
author | Juanhuix, Jordi Gil-Ortiz, Fernando Cuní, Guifré Colldelram, Carles Nicolás, Josep Lidón, Julio Boter, Eva Ruget, Claude Ferrer, Salvador Benach, Jordi |
author_facet | Juanhuix, Jordi Gil-Ortiz, Fernando Cuní, Guifré Colldelram, Carles Nicolás, Josep Lidón, Julio Boter, Eva Ruget, Claude Ferrer, Salvador Benach, Jordi |
author_sort | Juanhuix, Jordi |
collection | PubMed |
description | BL13-XALOC is currently the only macromolecular crystallography beamline at the 3 GeV ALBA synchrotron near Barcelona, Spain. The optics design is based on an in-vacuum undulator, a Si(111) channel-cut crystal monochromator and a pair of KB mirrors. It allows three main operation modes: a focused configuration, where both mirrors can focus the beam at the sample position to 52 µm × 5.5 µm FWHM (H × V); a defocused configuration that can match the size of the beam to the dimensions of the crystals or to focus the beam at the detector; and an unfocused configuration, where one or both mirrors are removed from the photon beam path. To achieve a uniform defocused beam, the slope errors of the mirrors were reduced down to 55 nrad RMS by employing a novel method that has been developed at the ALBA high-accuracy metrology laboratory. Thorough commissioning with X-ray beam and user operation has demonstrated an excellent energy and spatial stability of the beamline. The end-station includes a high-accuracy single-axis diffractometer, a removable mini-kappa stage, an automated sample-mounting robot and a photon-counting detector that allows shutterless operation. The positioning tables of the diffractometer and the detector are based on a novel and highly stable design. This equipment, together with the operation flexibility of the beamline, allows a large variety of types of crystals to be tackled, from medium-sized crystals with large unit-cell parameters to microcrystals. Several examples of data collections measured during beamline commissioning are described. The beamline started user operation on 18 July 2012. |
format | Online Article Text |
id | pubmed-4073956 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | International Union of Crystallography |
record_format | MEDLINE/PubMed |
spelling | pubmed-40739562014-07-16 Developments in optics and performance at BL13-XALOC, the macromolecular crystallography beamline at the Alba Synchrotron Juanhuix, Jordi Gil-Ortiz, Fernando Cuní, Guifré Colldelram, Carles Nicolás, Josep Lidón, Julio Boter, Eva Ruget, Claude Ferrer, Salvador Benach, Jordi J Synchrotron Radiat Research Papers BL13-XALOC is currently the only macromolecular crystallography beamline at the 3 GeV ALBA synchrotron near Barcelona, Spain. The optics design is based on an in-vacuum undulator, a Si(111) channel-cut crystal monochromator and a pair of KB mirrors. It allows three main operation modes: a focused configuration, where both mirrors can focus the beam at the sample position to 52 µm × 5.5 µm FWHM (H × V); a defocused configuration that can match the size of the beam to the dimensions of the crystals or to focus the beam at the detector; and an unfocused configuration, where one or both mirrors are removed from the photon beam path. To achieve a uniform defocused beam, the slope errors of the mirrors were reduced down to 55 nrad RMS by employing a novel method that has been developed at the ALBA high-accuracy metrology laboratory. Thorough commissioning with X-ray beam and user operation has demonstrated an excellent energy and spatial stability of the beamline. The end-station includes a high-accuracy single-axis diffractometer, a removable mini-kappa stage, an automated sample-mounting robot and a photon-counting detector that allows shutterless operation. The positioning tables of the diffractometer and the detector are based on a novel and highly stable design. This equipment, together with the operation flexibility of the beamline, allows a large variety of types of crystals to be tackled, from medium-sized crystals with large unit-cell parameters to microcrystals. Several examples of data collections measured during beamline commissioning are described. The beamline started user operation on 18 July 2012. International Union of Crystallography 2014-05-20 /pmc/articles/PMC4073956/ /pubmed/24971961 http://dx.doi.org/10.1107/S160057751400825X Text en © Jordi Juanhuix et al. 2014 http://creativecommons.org/licenses/by/2.0/uk/ This is an open-access article distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited. |
spellingShingle | Research Papers Juanhuix, Jordi Gil-Ortiz, Fernando Cuní, Guifré Colldelram, Carles Nicolás, Josep Lidón, Julio Boter, Eva Ruget, Claude Ferrer, Salvador Benach, Jordi Developments in optics and performance at BL13-XALOC, the macromolecular crystallography beamline at the Alba Synchrotron |
title | Developments in optics and performance at BL13-XALOC, the macromolecular crystallography beamline at the Alba Synchrotron |
title_full | Developments in optics and performance at BL13-XALOC, the macromolecular crystallography beamline at the Alba Synchrotron |
title_fullStr | Developments in optics and performance at BL13-XALOC, the macromolecular crystallography beamline at the Alba Synchrotron |
title_full_unstemmed | Developments in optics and performance at BL13-XALOC, the macromolecular crystallography beamline at the Alba Synchrotron |
title_short | Developments in optics and performance at BL13-XALOC, the macromolecular crystallography beamline at the Alba Synchrotron |
title_sort | developments in optics and performance at bl13-xaloc, the macromolecular crystallography beamline at the alba synchrotron |
topic | Research Papers |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4073956/ https://www.ncbi.nlm.nih.gov/pubmed/24971961 http://dx.doi.org/10.1107/S160057751400825X |
work_keys_str_mv | AT juanhuixjordi developmentsinopticsandperformanceatbl13xalocthemacromolecularcrystallographybeamlineatthealbasynchrotron AT gilortizfernando developmentsinopticsandperformanceatbl13xalocthemacromolecularcrystallographybeamlineatthealbasynchrotron AT cuniguifre developmentsinopticsandperformanceatbl13xalocthemacromolecularcrystallographybeamlineatthealbasynchrotron AT colldelramcarles developmentsinopticsandperformanceatbl13xalocthemacromolecularcrystallographybeamlineatthealbasynchrotron AT nicolasjosep developmentsinopticsandperformanceatbl13xalocthemacromolecularcrystallographybeamlineatthealbasynchrotron AT lidonjulio developmentsinopticsandperformanceatbl13xalocthemacromolecularcrystallographybeamlineatthealbasynchrotron AT botereva developmentsinopticsandperformanceatbl13xalocthemacromolecularcrystallographybeamlineatthealbasynchrotron AT rugetclaude developmentsinopticsandperformanceatbl13xalocthemacromolecularcrystallographybeamlineatthealbasynchrotron AT ferrersalvador developmentsinopticsandperformanceatbl13xalocthemacromolecularcrystallographybeamlineatthealbasynchrotron AT benachjordi developmentsinopticsandperformanceatbl13xalocthemacromolecularcrystallographybeamlineatthealbasynchrotron |