Cargando…

Efficacy of arthroscopically placed pain catheter adjacent to the suprascapular nerve (continuous arthroscopically assisted suprascapular nerve block) following arthroscopic rotator-cuff repair

BACKGROUND: Rotator-cuff surgery is well recognized to be a painful procedure. OBJECTIVES: The purpose of this study was to examine the effectiveness of an arthroscopically placed perineural catheter at the scapular notch to provide a continuous block of the suprascapular nerve (continuous arthrosco...

Descripción completa

Detalles Bibliográficos
Autor principal: Yamakado, Kotaro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4074897/
https://www.ncbi.nlm.nih.gov/pubmed/24982592
http://dx.doi.org/10.2147/OAJSM.S63345
_version_ 1782323266164097024
author Yamakado, Kotaro
author_facet Yamakado, Kotaro
author_sort Yamakado, Kotaro
collection PubMed
description BACKGROUND: Rotator-cuff surgery is well recognized to be a painful procedure. OBJECTIVES: The purpose of this study was to examine the effectiveness of an arthroscopically placed perineural catheter at the scapular notch to provide a continuous block of the suprascapular nerve (continuous arthroscopically assisted suprascapular nerve block [ca-SSNB]) following arthroscopic rotator-cuff repair (ARCR). MATERIALS AND METHODS: This level II, prospective, randomized, controlled trial without postoperative blinding included 40 patients, who had a 48-hour pain pump, with 0.2% ropivacaine infusion and a continuous rate of 3 mL/hour, placed via an arthroscopically placed catheter following ARCR with arthroscopic release of the superior transverse ligament: 21 patients had a ca-SSNB, and 19 patients had a continuous subacromial bursal block (SAB). The visual analog scale (at 6 hours and on the first, second, and third postoperative days) and the total number of additional pain-reduction attempts during the 3 postoperative days were calculated. RESULTS: The respective visual analog scale scores (mm) obtained from the ca-SSNB and SAB groups were 62.4 and 67.6 (P=0.73) before surgery, 9.1 and 19.4 (P=0.12) at 6 hours after surgery, 24.4 and 44.6 (P=0.019) on the first postoperative day, 19.4 and 40.4 (P=0.0060) on the second postoperative day, and 18.5 and 27.8 (P=0.21) on the third postoperative day. Total additional pain-reduction attempts recorded for the ca-SSNB and SAB groups during the 3 postoperative days were 0.3 times and 1.2 times (P=0.0020), respectively. CONCLUSION: ca-SSNB was highly effective in controlling postoperative pain after ARCR.
format Online
Article
Text
id pubmed-4074897
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-40748972014-06-30 Efficacy of arthroscopically placed pain catheter adjacent to the suprascapular nerve (continuous arthroscopically assisted suprascapular nerve block) following arthroscopic rotator-cuff repair Yamakado, Kotaro Open Access J Sports Med Original Research BACKGROUND: Rotator-cuff surgery is well recognized to be a painful procedure. OBJECTIVES: The purpose of this study was to examine the effectiveness of an arthroscopically placed perineural catheter at the scapular notch to provide a continuous block of the suprascapular nerve (continuous arthroscopically assisted suprascapular nerve block [ca-SSNB]) following arthroscopic rotator-cuff repair (ARCR). MATERIALS AND METHODS: This level II, prospective, randomized, controlled trial without postoperative blinding included 40 patients, who had a 48-hour pain pump, with 0.2% ropivacaine infusion and a continuous rate of 3 mL/hour, placed via an arthroscopically placed catheter following ARCR with arthroscopic release of the superior transverse ligament: 21 patients had a ca-SSNB, and 19 patients had a continuous subacromial bursal block (SAB). The visual analog scale (at 6 hours and on the first, second, and third postoperative days) and the total number of additional pain-reduction attempts during the 3 postoperative days were calculated. RESULTS: The respective visual analog scale scores (mm) obtained from the ca-SSNB and SAB groups were 62.4 and 67.6 (P=0.73) before surgery, 9.1 and 19.4 (P=0.12) at 6 hours after surgery, 24.4 and 44.6 (P=0.019) on the first postoperative day, 19.4 and 40.4 (P=0.0060) on the second postoperative day, and 18.5 and 27.8 (P=0.21) on the third postoperative day. Total additional pain-reduction attempts recorded for the ca-SSNB and SAB groups during the 3 postoperative days were 0.3 times and 1.2 times (P=0.0020), respectively. CONCLUSION: ca-SSNB was highly effective in controlling postoperative pain after ARCR. Dove Medical Press 2014-05-21 /pmc/articles/PMC4074897/ /pubmed/24982592 http://dx.doi.org/10.2147/OAJSM.S63345 Text en © 2014 Yamakado. This work is published by Dove Medical Press Limited, and licensed under Creative Commons Attribution – Non Commercial (unported, v3.0) License The full terms of the License are available at http://creativecommons.org/licenses/by-nc/3.0/. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Yamakado, Kotaro
Efficacy of arthroscopically placed pain catheter adjacent to the suprascapular nerve (continuous arthroscopically assisted suprascapular nerve block) following arthroscopic rotator-cuff repair
title Efficacy of arthroscopically placed pain catheter adjacent to the suprascapular nerve (continuous arthroscopically assisted suprascapular nerve block) following arthroscopic rotator-cuff repair
title_full Efficacy of arthroscopically placed pain catheter adjacent to the suprascapular nerve (continuous arthroscopically assisted suprascapular nerve block) following arthroscopic rotator-cuff repair
title_fullStr Efficacy of arthroscopically placed pain catheter adjacent to the suprascapular nerve (continuous arthroscopically assisted suprascapular nerve block) following arthroscopic rotator-cuff repair
title_full_unstemmed Efficacy of arthroscopically placed pain catheter adjacent to the suprascapular nerve (continuous arthroscopically assisted suprascapular nerve block) following arthroscopic rotator-cuff repair
title_short Efficacy of arthroscopically placed pain catheter adjacent to the suprascapular nerve (continuous arthroscopically assisted suprascapular nerve block) following arthroscopic rotator-cuff repair
title_sort efficacy of arthroscopically placed pain catheter adjacent to the suprascapular nerve (continuous arthroscopically assisted suprascapular nerve block) following arthroscopic rotator-cuff repair
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4074897/
https://www.ncbi.nlm.nih.gov/pubmed/24982592
http://dx.doi.org/10.2147/OAJSM.S63345
work_keys_str_mv AT yamakadokotaro efficacyofarthroscopicallyplacedpaincatheteradjacenttothesuprascapularnervecontinuousarthroscopicallyassistedsuprascapularnerveblockfollowingarthroscopicrotatorcuffrepair