Cargando…

A 10-second fluid challenge guided by transthoracic echocardiography can predict fluid responsiveness

INTRODUCTION: The accurate assessment of intravascular volume status for the therapy of severe hypovolemia and shock is difficult and critical to critically ill patients. Non-invasive evaluation of fluid responsiveness by the rapid infusion of a very limited amount of volume is an important clinical...

Descripción completa

Detalles Bibliográficos
Autores principales: Wu, Yunfan, Zhou, Shusheng, Zhou, Zhihua, Liu, Bao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4075154/
https://www.ncbi.nlm.nih.gov/pubmed/24886990
http://dx.doi.org/10.1186/cc13891
_version_ 1782323298696167424
author Wu, Yunfan
Zhou, Shusheng
Zhou, Zhihua
Liu, Bao
author_facet Wu, Yunfan
Zhou, Shusheng
Zhou, Zhihua
Liu, Bao
author_sort Wu, Yunfan
collection PubMed
description INTRODUCTION: The accurate assessment of intravascular volume status for the therapy of severe hypovolemia and shock is difficult and critical to critically ill patients. Non-invasive evaluation of fluid responsiveness by the rapid infusion of a very limited amount of volume is an important clinical goal. This study aimed to test whether echocardiographic parameters could predict fluid responsiveness in critically ill patients following a low-volume (50-ml crystalloid solution) infusion over 10 seconds. METHODS: We prospectively studied 55 mechanically ventilated patients. Echocardiography was performed during a 50-ml infusion of crystalloid solution over 10 seconds and a further 450 ml over 15 minutes. Cardiac output (CO), stroke volume (SV), aortic velocity time index (VTI), and left ventricular ejection fraction (LVEF) were recorded. Patients were classified as responders (Rs) if CO increased by at least 15% following the 500-ml volume expansion or were classified as non-responders (NRs) if CO increased by less than 15%. Area under the receiver operating characteristic curves (AUC) compared CO variations after 50 ml over 10 seconds (∆CO50) and 500 ml over 15 minutes (∆CO500) and the variation of VTI after infusion of 50 ml of fluid over 10 seconds (∆VTI50). RESULTS: In total, 50 patients were enrolled, and 27 (54%) of them were Rs. General characteristics, LVEF, heart rate, and central venous pressure were similar between Rs and NRs. In the Rs group, the AUC for ∆CO50 was 0.95 ± 0.03 (P <0.01; best cutoff value, 6%; sensitivity, 93%; specificity, 91%). Moreover, ∆CO50 and ∆CO500 were strongly correlated (r = 0.87; P <0.01). The AUC for ∆VTI50 was 0.91 ± 0.04 (P <0.01; best cutoff value, 9%; sensitivity, 74%; specificity, 95%). ∆VTI50 and ∆CO500 were positively correlated (r = 0.72; P <0.01). CONCLUSION: In critically ill patients, the variation of CO and VTI after the administration of 50-ml crystalloid solution over 10 seconds (∆CO50 and ∆VTI50) can accurately predict fluid responsiveness. TRIAL REGISTRATION: Current Controlled Trials ISRCTN10524328. Registered 12 December 2013.
format Online
Article
Text
id pubmed-4075154
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-40751542014-07-01 A 10-second fluid challenge guided by transthoracic echocardiography can predict fluid responsiveness Wu, Yunfan Zhou, Shusheng Zhou, Zhihua Liu, Bao Crit Care Research INTRODUCTION: The accurate assessment of intravascular volume status for the therapy of severe hypovolemia and shock is difficult and critical to critically ill patients. Non-invasive evaluation of fluid responsiveness by the rapid infusion of a very limited amount of volume is an important clinical goal. This study aimed to test whether echocardiographic parameters could predict fluid responsiveness in critically ill patients following a low-volume (50-ml crystalloid solution) infusion over 10 seconds. METHODS: We prospectively studied 55 mechanically ventilated patients. Echocardiography was performed during a 50-ml infusion of crystalloid solution over 10 seconds and a further 450 ml over 15 minutes. Cardiac output (CO), stroke volume (SV), aortic velocity time index (VTI), and left ventricular ejection fraction (LVEF) were recorded. Patients were classified as responders (Rs) if CO increased by at least 15% following the 500-ml volume expansion or were classified as non-responders (NRs) if CO increased by less than 15%. Area under the receiver operating characteristic curves (AUC) compared CO variations after 50 ml over 10 seconds (∆CO50) and 500 ml over 15 minutes (∆CO500) and the variation of VTI after infusion of 50 ml of fluid over 10 seconds (∆VTI50). RESULTS: In total, 50 patients were enrolled, and 27 (54%) of them were Rs. General characteristics, LVEF, heart rate, and central venous pressure were similar between Rs and NRs. In the Rs group, the AUC for ∆CO50 was 0.95 ± 0.03 (P <0.01; best cutoff value, 6%; sensitivity, 93%; specificity, 91%). Moreover, ∆CO50 and ∆CO500 were strongly correlated (r = 0.87; P <0.01). The AUC for ∆VTI50 was 0.91 ± 0.04 (P <0.01; best cutoff value, 9%; sensitivity, 74%; specificity, 95%). ∆VTI50 and ∆CO500 were positively correlated (r = 0.72; P <0.01). CONCLUSION: In critically ill patients, the variation of CO and VTI after the administration of 50-ml crystalloid solution over 10 seconds (∆CO50 and ∆VTI50) can accurately predict fluid responsiveness. TRIAL REGISTRATION: Current Controlled Trials ISRCTN10524328. Registered 12 December 2013. BioMed Central 2014 2014-05-27 /pmc/articles/PMC4075154/ /pubmed/24886990 http://dx.doi.org/10.1186/cc13891 Text en Copyright © 2014 Wu et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Wu, Yunfan
Zhou, Shusheng
Zhou, Zhihua
Liu, Bao
A 10-second fluid challenge guided by transthoracic echocardiography can predict fluid responsiveness
title A 10-second fluid challenge guided by transthoracic echocardiography can predict fluid responsiveness
title_full A 10-second fluid challenge guided by transthoracic echocardiography can predict fluid responsiveness
title_fullStr A 10-second fluid challenge guided by transthoracic echocardiography can predict fluid responsiveness
title_full_unstemmed A 10-second fluid challenge guided by transthoracic echocardiography can predict fluid responsiveness
title_short A 10-second fluid challenge guided by transthoracic echocardiography can predict fluid responsiveness
title_sort 10-second fluid challenge guided by transthoracic echocardiography can predict fluid responsiveness
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4075154/
https://www.ncbi.nlm.nih.gov/pubmed/24886990
http://dx.doi.org/10.1186/cc13891
work_keys_str_mv AT wuyunfan a10secondfluidchallengeguidedbytransthoracicechocardiographycanpredictfluidresponsiveness
AT zhoushusheng a10secondfluidchallengeguidedbytransthoracicechocardiographycanpredictfluidresponsiveness
AT zhouzhihua a10secondfluidchallengeguidedbytransthoracicechocardiographycanpredictfluidresponsiveness
AT liubao a10secondfluidchallengeguidedbytransthoracicechocardiographycanpredictfluidresponsiveness
AT wuyunfan 10secondfluidchallengeguidedbytransthoracicechocardiographycanpredictfluidresponsiveness
AT zhoushusheng 10secondfluidchallengeguidedbytransthoracicechocardiographycanpredictfluidresponsiveness
AT zhouzhihua 10secondfluidchallengeguidedbytransthoracicechocardiographycanpredictfluidresponsiveness
AT liubao 10secondfluidchallengeguidedbytransthoracicechocardiographycanpredictfluidresponsiveness