Cargando…

Reference values for the incremental shuttle walk test in healthy subjects: from the walk distance to physiological responses ,

OBJECTIVE: To determine reference values for incremental shuttle walk distance (ISWD) and peak physiological responses during the incremental shuttle walk test (ISWT), as well as to develop a series of predictive equations for those variables in healthy adults. METHODS: We evaluated 103 healthy part...

Descripción completa

Detalles Bibliográficos
Autores principales: Dourado, Victor Zuniga, Guerra, Ricardo Luís Fernandes, Tanni, Suzana Erico, Antunes, Letícia Cláudia de Oliveira, Godoy, Irma
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Sociedade Brasileira de Pneumologia e Tisiologia 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4075833/
https://www.ncbi.nlm.nih.gov/pubmed/23670504
http://dx.doi.org/10.1590/S1806-37132013000200010
_version_ 1782323401718759424
author Dourado, Victor Zuniga
Guerra, Ricardo Luís Fernandes
Tanni, Suzana Erico
Antunes, Letícia Cláudia de Oliveira
Godoy, Irma
author_facet Dourado, Victor Zuniga
Guerra, Ricardo Luís Fernandes
Tanni, Suzana Erico
Antunes, Letícia Cláudia de Oliveira
Godoy, Irma
author_sort Dourado, Victor Zuniga
collection PubMed
description OBJECTIVE: To determine reference values for incremental shuttle walk distance (ISWD) and peak physiological responses during the incremental shuttle walk test (ISWT), as well as to develop a series of predictive equations for those variables in healthy adults. METHODS: We evaluated 103 healthy participants ≥ 40 years of age (54 women and 49 men). We fitted each participant with a gas analysis system for use during the ISWT. Oxygen consumption (VO(2)), carbon dioxide production, minute ventilation, heart rate (HR), ISWD, and maximal walking velocity (MWV) were obtained as primary outcomes. We also assessed hand grip strength (HGS) and lean body mass (LBM). RESULTS: The regression analysis models, including physiological variables, ISWD, and MWV (adjusted for age, body mass, height, and sex), produced R(2) values ranging from 0.40 to 0.65 (for HR and peak VO(2), respectively). Using the models including LBM or HGS, we obtained no significant increase in the R(2) values for predicting peak VO(2), although the use of those models did result in slight increases in the R(2) values for ISWD and MWV (of 8% and 12%, respectively). The variables ISWD, MWV, and ISWD × body mass, respectively, explained 76.7%, 73.3%, and 81.2% of peak VO(2) variability. CONCLUSIONS: Our results provide reference values for ISWD and physiological responses to the ISWT, which can be properly estimated by determining simple demographic and anthropometric characteristics in healthy adults ≥ 40 years of age. The ISWT could be used in assessing physical fitness in the general adult population and in designing individualized walking programs.
format Online
Article
Text
id pubmed-4075833
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Sociedade Brasileira de Pneumologia e Tisiologia
record_format MEDLINE/PubMed
spelling pubmed-40758332014-07-16 Reference values for the incremental shuttle walk test in healthy subjects: from the walk distance to physiological responses , Dourado, Victor Zuniga Guerra, Ricardo Luís Fernandes Tanni, Suzana Erico Antunes, Letícia Cláudia de Oliveira Godoy, Irma J Bras Pneumol Original Article OBJECTIVE: To determine reference values for incremental shuttle walk distance (ISWD) and peak physiological responses during the incremental shuttle walk test (ISWT), as well as to develop a series of predictive equations for those variables in healthy adults. METHODS: We evaluated 103 healthy participants ≥ 40 years of age (54 women and 49 men). We fitted each participant with a gas analysis system for use during the ISWT. Oxygen consumption (VO(2)), carbon dioxide production, minute ventilation, heart rate (HR), ISWD, and maximal walking velocity (MWV) were obtained as primary outcomes. We also assessed hand grip strength (HGS) and lean body mass (LBM). RESULTS: The regression analysis models, including physiological variables, ISWD, and MWV (adjusted for age, body mass, height, and sex), produced R(2) values ranging from 0.40 to 0.65 (for HR and peak VO(2), respectively). Using the models including LBM or HGS, we obtained no significant increase in the R(2) values for predicting peak VO(2), although the use of those models did result in slight increases in the R(2) values for ISWD and MWV (of 8% and 12%, respectively). The variables ISWD, MWV, and ISWD × body mass, respectively, explained 76.7%, 73.3%, and 81.2% of peak VO(2) variability. CONCLUSIONS: Our results provide reference values for ISWD and physiological responses to the ISWT, which can be properly estimated by determining simple demographic and anthropometric characteristics in healthy adults ≥ 40 years of age. The ISWT could be used in assessing physical fitness in the general adult population and in designing individualized walking programs. Sociedade Brasileira de Pneumologia e Tisiologia 2013 /pmc/articles/PMC4075833/ /pubmed/23670504 http://dx.doi.org/10.1590/S1806-37132013000200010 Text en http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Dourado, Victor Zuniga
Guerra, Ricardo Luís Fernandes
Tanni, Suzana Erico
Antunes, Letícia Cláudia de Oliveira
Godoy, Irma
Reference values for the incremental shuttle walk test in healthy subjects: from the walk distance to physiological responses ,
title Reference values for the incremental shuttle walk test in healthy subjects: from the walk distance to physiological responses ,
title_full Reference values for the incremental shuttle walk test in healthy subjects: from the walk distance to physiological responses ,
title_fullStr Reference values for the incremental shuttle walk test in healthy subjects: from the walk distance to physiological responses ,
title_full_unstemmed Reference values for the incremental shuttle walk test in healthy subjects: from the walk distance to physiological responses ,
title_short Reference values for the incremental shuttle walk test in healthy subjects: from the walk distance to physiological responses ,
title_sort reference values for the incremental shuttle walk test in healthy subjects: from the walk distance to physiological responses ,
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4075833/
https://www.ncbi.nlm.nih.gov/pubmed/23670504
http://dx.doi.org/10.1590/S1806-37132013000200010
work_keys_str_mv AT douradovictorzuniga referencevaluesfortheincrementalshuttlewalktestinhealthysubjectsfromthewalkdistancetophysiologicalresponses
AT guerraricardoluisfernandes referencevaluesfortheincrementalshuttlewalktestinhealthysubjectsfromthewalkdistancetophysiologicalresponses
AT tannisuzanaerico referencevaluesfortheincrementalshuttlewalktestinhealthysubjectsfromthewalkdistancetophysiologicalresponses
AT antunesleticiaclaudiadeoliveira referencevaluesfortheincrementalshuttlewalktestinhealthysubjectsfromthewalkdistancetophysiologicalresponses
AT godoyirma referencevaluesfortheincrementalshuttlewalktestinhealthysubjectsfromthewalkdistancetophysiologicalresponses