Cargando…

Chest compression with a higher level of pressure support ventilation: effects on secretion removal, hemodynamics, and respiratory mechanics in patients on mechanical ventilation

OBJECTIVE: To determine the efficacy of chest compression accompanied by a 10-cmH(2)O increase in baseline inspiratory pressure on pressure support ventilation, in comparison with that of aspiration alone, in removing secretions, normalizing hemodynamics, and improving respiratory mechanics in patie...

Descripción completa

Detalles Bibliográficos
Autores principales: Naue, Wagner da Silva, Forgiarini, Luiz Alberto, Dias, Alexandre Simões, Vieira, Silvia Regina Rios
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Sociedade Brasileira de Pneumologia e Tisiologia 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4075919/
https://www.ncbi.nlm.nih.gov/pubmed/24626270
http://dx.doi.org/10.1590/S1806-37132014000100008
Descripción
Sumario:OBJECTIVE: To determine the efficacy of chest compression accompanied by a 10-cmH(2)O increase in baseline inspiratory pressure on pressure support ventilation, in comparison with that of aspiration alone, in removing secretions, normalizing hemodynamics, and improving respiratory mechanics in patients on mechanical ventilation. METHODS: This was a randomized crossover clinical trial involving patients on mechanical ventilation for more than 48 h in the ICU of the Porto Alegre Hospital de Clínicas, in the city of Porto Alegre, Brazil. Patients were randomized to receive aspiration alone (control group) or compression accompanied by a 10-cmH(2)O increase in baseline inspiratory pressure on pressure support ventilation (intervention group). We measured hemodynamic parameters, respiratory mechanics parameters, and the amount of secretions collected. RESULTS: We included 34 patients. The mean age was 64.2 ± 14.6 years. In comparison with the control group, the intervention group showed a higher median amount of secretions collected (1.9 g vs. 2.3 g; p = 0.004), a greater increase in mean expiratory tidal volume (16 ± 69 mL vs. 56 ± 69 mL; p = 0.018), and a greater increase in mean dynamic compliance (0.1 ± 4.9 cmH(2)O vs. 2.8 ± 4.5 cmH(2)O; p = 0.005). CONCLUSIONS: In this sample, chest compression accompanied by an increase in pressure support significantly increased the amount of secretions removed, the expiratory tidal volume, and dynamic compliance. (ClinicalTrials.gov Identifier:NCT01155648 [http://www.clinicaltrials.gov/])