Cargando…

Low Cardiac Output Secondary to a Malpositioned Umbilical Venous Catheter: Value of Targeted Neonatal Echocardiography

Systemic hypotension is common in very low birthweight preterm infants but the nature of the precipitating cause may be unclear. Targeted neonatal echocardiography (TnEcho) is being increasingly used to support hemodynamic decisions in the neonatal intensive care unit (NICU), including identifying i...

Descripción completa

Detalles Bibliográficos
Autores principales: Weisz, Dany E., Poon, Wei Bing, James, Andrew, McNamara, Patrick J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Thieme Medical Publishers 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4078164/
https://www.ncbi.nlm.nih.gov/pubmed/25032055
http://dx.doi.org/10.1055/s-0034-1368090
_version_ 1782323698335744000
author Weisz, Dany E.
Poon, Wei Bing
James, Andrew
McNamara, Patrick J.
author_facet Weisz, Dany E.
Poon, Wei Bing
James, Andrew
McNamara, Patrick J.
author_sort Weisz, Dany E.
collection PubMed
description Systemic hypotension is common in very low birthweight preterm infants but the nature of the precipitating cause may be unclear. Targeted neonatal echocardiography (TnEcho) is being increasingly used to support hemodynamic decisions in the neonatal intensive care unit (NICU), including identifying impairments in the transitional circulation of preterm infants, providing timely re-evaluation after institution of therapies and evaluating the placement of indwelling catheters. We present a case of a preterm infant with systemic hypotension and low cardiac output secondary to a large transatrial shunt induced by a malpositioned umbilical venous catheter. Repositioning of the line led to resolution of the hemodynamic disturbance and clinical instability, highlighting the utility of TnEcho in the NICU.
format Online
Article
Text
id pubmed-4078164
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Thieme Medical Publishers
record_format MEDLINE/PubMed
spelling pubmed-40781642014-07-16 Low Cardiac Output Secondary to a Malpositioned Umbilical Venous Catheter: Value of Targeted Neonatal Echocardiography Weisz, Dany E. Poon, Wei Bing James, Andrew McNamara, Patrick J. AJP Rep Article Systemic hypotension is common in very low birthweight preterm infants but the nature of the precipitating cause may be unclear. Targeted neonatal echocardiography (TnEcho) is being increasingly used to support hemodynamic decisions in the neonatal intensive care unit (NICU), including identifying impairments in the transitional circulation of preterm infants, providing timely re-evaluation after institution of therapies and evaluating the placement of indwelling catheters. We present a case of a preterm infant with systemic hypotension and low cardiac output secondary to a large transatrial shunt induced by a malpositioned umbilical venous catheter. Repositioning of the line led to resolution of the hemodynamic disturbance and clinical instability, highlighting the utility of TnEcho in the NICU. Thieme Medical Publishers 2014-03-03 2014-05 /pmc/articles/PMC4078164/ /pubmed/25032055 http://dx.doi.org/10.1055/s-0034-1368090 Text en © Thieme Medical Publishers
spellingShingle Article
Weisz, Dany E.
Poon, Wei Bing
James, Andrew
McNamara, Patrick J.
Low Cardiac Output Secondary to a Malpositioned Umbilical Venous Catheter: Value of Targeted Neonatal Echocardiography
title Low Cardiac Output Secondary to a Malpositioned Umbilical Venous Catheter: Value of Targeted Neonatal Echocardiography
title_full Low Cardiac Output Secondary to a Malpositioned Umbilical Venous Catheter: Value of Targeted Neonatal Echocardiography
title_fullStr Low Cardiac Output Secondary to a Malpositioned Umbilical Venous Catheter: Value of Targeted Neonatal Echocardiography
title_full_unstemmed Low Cardiac Output Secondary to a Malpositioned Umbilical Venous Catheter: Value of Targeted Neonatal Echocardiography
title_short Low Cardiac Output Secondary to a Malpositioned Umbilical Venous Catheter: Value of Targeted Neonatal Echocardiography
title_sort low cardiac output secondary to a malpositioned umbilical venous catheter: value of targeted neonatal echocardiography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4078164/
https://www.ncbi.nlm.nih.gov/pubmed/25032055
http://dx.doi.org/10.1055/s-0034-1368090
work_keys_str_mv AT weiszdanye lowcardiacoutputsecondarytoamalpositionedumbilicalvenouscathetervalueoftargetedneonatalechocardiography
AT poonweibing lowcardiacoutputsecondarytoamalpositionedumbilicalvenouscathetervalueoftargetedneonatalechocardiography
AT jamesandrew lowcardiacoutputsecondarytoamalpositionedumbilicalvenouscathetervalueoftargetedneonatalechocardiography
AT mcnamarapatrickj lowcardiacoutputsecondarytoamalpositionedumbilicalvenouscathetervalueoftargetedneonatalechocardiography