Cargando…
Low Cardiac Output Secondary to a Malpositioned Umbilical Venous Catheter: Value of Targeted Neonatal Echocardiography
Systemic hypotension is common in very low birthweight preterm infants but the nature of the precipitating cause may be unclear. Targeted neonatal echocardiography (TnEcho) is being increasingly used to support hemodynamic decisions in the neonatal intensive care unit (NICU), including identifying i...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Thieme Medical Publishers
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4078164/ https://www.ncbi.nlm.nih.gov/pubmed/25032055 http://dx.doi.org/10.1055/s-0034-1368090 |
_version_ | 1782323698335744000 |
---|---|
author | Weisz, Dany E. Poon, Wei Bing James, Andrew McNamara, Patrick J. |
author_facet | Weisz, Dany E. Poon, Wei Bing James, Andrew McNamara, Patrick J. |
author_sort | Weisz, Dany E. |
collection | PubMed |
description | Systemic hypotension is common in very low birthweight preterm infants but the nature of the precipitating cause may be unclear. Targeted neonatal echocardiography (TnEcho) is being increasingly used to support hemodynamic decisions in the neonatal intensive care unit (NICU), including identifying impairments in the transitional circulation of preterm infants, providing timely re-evaluation after institution of therapies and evaluating the placement of indwelling catheters. We present a case of a preterm infant with systemic hypotension and low cardiac output secondary to a large transatrial shunt induced by a malpositioned umbilical venous catheter. Repositioning of the line led to resolution of the hemodynamic disturbance and clinical instability, highlighting the utility of TnEcho in the NICU. |
format | Online Article Text |
id | pubmed-4078164 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Thieme Medical Publishers |
record_format | MEDLINE/PubMed |
spelling | pubmed-40781642014-07-16 Low Cardiac Output Secondary to a Malpositioned Umbilical Venous Catheter: Value of Targeted Neonatal Echocardiography Weisz, Dany E. Poon, Wei Bing James, Andrew McNamara, Patrick J. AJP Rep Article Systemic hypotension is common in very low birthweight preterm infants but the nature of the precipitating cause may be unclear. Targeted neonatal echocardiography (TnEcho) is being increasingly used to support hemodynamic decisions in the neonatal intensive care unit (NICU), including identifying impairments in the transitional circulation of preterm infants, providing timely re-evaluation after institution of therapies and evaluating the placement of indwelling catheters. We present a case of a preterm infant with systemic hypotension and low cardiac output secondary to a large transatrial shunt induced by a malpositioned umbilical venous catheter. Repositioning of the line led to resolution of the hemodynamic disturbance and clinical instability, highlighting the utility of TnEcho in the NICU. Thieme Medical Publishers 2014-03-03 2014-05 /pmc/articles/PMC4078164/ /pubmed/25032055 http://dx.doi.org/10.1055/s-0034-1368090 Text en © Thieme Medical Publishers |
spellingShingle | Article Weisz, Dany E. Poon, Wei Bing James, Andrew McNamara, Patrick J. Low Cardiac Output Secondary to a Malpositioned Umbilical Venous Catheter: Value of Targeted Neonatal Echocardiography |
title | Low Cardiac Output Secondary to a Malpositioned Umbilical Venous Catheter: Value of Targeted Neonatal Echocardiography |
title_full | Low Cardiac Output Secondary to a Malpositioned Umbilical Venous Catheter: Value of Targeted Neonatal Echocardiography |
title_fullStr | Low Cardiac Output Secondary to a Malpositioned Umbilical Venous Catheter: Value of Targeted Neonatal Echocardiography |
title_full_unstemmed | Low Cardiac Output Secondary to a Malpositioned Umbilical Venous Catheter: Value of Targeted Neonatal Echocardiography |
title_short | Low Cardiac Output Secondary to a Malpositioned Umbilical Venous Catheter: Value of Targeted Neonatal Echocardiography |
title_sort | low cardiac output secondary to a malpositioned umbilical venous catheter: value of targeted neonatal echocardiography |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4078164/ https://www.ncbi.nlm.nih.gov/pubmed/25032055 http://dx.doi.org/10.1055/s-0034-1368090 |
work_keys_str_mv | AT weiszdanye lowcardiacoutputsecondarytoamalpositionedumbilicalvenouscathetervalueoftargetedneonatalechocardiography AT poonweibing lowcardiacoutputsecondarytoamalpositionedumbilicalvenouscathetervalueoftargetedneonatalechocardiography AT jamesandrew lowcardiacoutputsecondarytoamalpositionedumbilicalvenouscathetervalueoftargetedneonatalechocardiography AT mcnamarapatrickj lowcardiacoutputsecondarytoamalpositionedumbilicalvenouscathetervalueoftargetedneonatalechocardiography |