Cargando…
Assessment of Still and Moving Images in the Diagnosis of Gastric Lesions Using Magnifying Narrow-Band Imaging in a Prospective Multicenter Trial
OBJECTIVES: Magnifying narrow-band imaging (M-NBI) is more accurate than white-light imaging for diagnosing small gastric cancers. However, it is uncertain whether moving M-NBI images have additional effects in the diagnosis of gastric cancers compared with still images. DESIGN: A prospective multic...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4079511/ https://www.ncbi.nlm.nih.gov/pubmed/24988209 http://dx.doi.org/10.1371/journal.pone.0100857 |
Sumario: | OBJECTIVES: Magnifying narrow-band imaging (M-NBI) is more accurate than white-light imaging for diagnosing small gastric cancers. However, it is uncertain whether moving M-NBI images have additional effects in the diagnosis of gastric cancers compared with still images. DESIGN: A prospective multicenter cohort study. METHODS: To identify the additional benefits of moving M-NBI images by comparing the diagnostic accuracy of still images only with that of both still and moving images. Still and moving M-NBI images of 40 gastric lesions were obtained by an expert endoscopist prior to this prospective multicenter cohort study. Thirty-four endoscopists from ten different Japanese institutions participated in the prospective multicenter cohort study. Each study participant was first tested using only still M-NBI images (still image test), then tested 1 month later using both still and moving M-NBI images (moving image test). The main outcome was a difference in the diagnostic accuracy of cancerous versus noncancerous lesions between the still image test and the moving image test. RESULTS: Thirty-four endoscopists were analysed. There were no significant difference of cancerous versus noncancerous lesions between still and moving image tests in the diagnostic accuracy (59.9% versus 61.5%), sensitivity (53.4% versus 55.9%), and specificity (67.0% versus 67.6%). And there were no significant difference in the diagnostic accuracy between still and moving image tests of demarcation line (65.4% versus 65.5%), microvascular pattern (56.7% versus 56.9%), and microsurface pattern (48.1% versus 50.9%). Diagnostic accuracy showed no significant difference between the still and moving image tests in the subgroups of endoscopic findings of the lesions. CONCLUSIONS: The addition of moving M-NBI images to still M-NBI images does not improve the diagnostic accuracy for gastric lesions. It is reasonable to concentrate on taking sharp still M-NBI images during endoscopic observation and use them for diagnosis. TRIAL REGISTRATION: Umin.ac.jp UMIN-CTR000008048 |
---|