Cargando…

Commutability of Possible External Quality Assessment Materials for Cardiac Troponin Measurement

BACKGROUND: The measurement of cardiac troponin is crucial in the diagnosis of myocardial infarction. The performance of troponin measurement is most conveniently monitored by external quality assessment (EQA) programs. The commutability of EQA samples is often unknown and the effectiveness of EQA p...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Shunli, Zeng, Jie, Zhang, Chuanbao, Li, Yilong, Zhao, Haijian, Cheng, Fei, Yu, Songlin, Wang, Mo, Chen, Wenxiang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4085021/
https://www.ncbi.nlm.nih.gov/pubmed/25000586
http://dx.doi.org/10.1371/journal.pone.0102046
_version_ 1782324594293604352
author Zhang, Shunli
Zeng, Jie
Zhang, Chuanbao
Li, Yilong
Zhao, Haijian
Cheng, Fei
Yu, Songlin
Wang, Mo
Chen, Wenxiang
author_facet Zhang, Shunli
Zeng, Jie
Zhang, Chuanbao
Li, Yilong
Zhao, Haijian
Cheng, Fei
Yu, Songlin
Wang, Mo
Chen, Wenxiang
author_sort Zhang, Shunli
collection PubMed
description BACKGROUND: The measurement of cardiac troponin is crucial in the diagnosis of myocardial infarction. The performance of troponin measurement is most conveniently monitored by external quality assessment (EQA) programs. The commutability of EQA samples is often unknown and the effectiveness of EQA programs is limited. METHODS: Commutability of possible EQA materials was evaluated. Commercial control materials used in an EQA program, human serum pools prepared from patient samples, purified analyte preparations, swine sera from model animals and a set of patient samples were measured for cTnI with 4 assays including Abbott Architect, Beckman Access, Ortho Vitros and Siemens Centaur. The measurement results were logarithm-transformed, and the transformed data for patient samples were pairwise analyzed with Deming regression and 95% prediction intervals were calculated for each pair of assays. The commutability of the materials was evaluated by comparing the logarithmic results of the materials with the limits of the intervals. Matrix-related biases were estimated for noncommutable materials. The impact of matrix-related bias on EQA was analyzed and a possible correction for the bias was proposed. RESULTS: Human serum pools were commutable for all assays; purified analyte preparations were commutable for 2 of the 6 assay pairs; commercial control materials and swine sera were all noncommutable; swine sera showed no reactivity to Vitros assay. The matrix-related biases for noncommutable materials ranged from −83% to 944%. Matrix-related biases of the EQA materials caused major abnormal between-assay variations in the EQA program and correction of the biases normalized the variations. CONCLUSION: Commutability of materials has major impact on the effectiveness of EQA programs for cTnI measurement. Human serum pools prepared from patient samples are commutable and other materials are mostly noncommutable. EQA programs should include at least one human serum pool to allow proper interpretation of EQA results.
format Online
Article
Text
id pubmed-4085021
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-40850212014-07-09 Commutability of Possible External Quality Assessment Materials for Cardiac Troponin Measurement Zhang, Shunli Zeng, Jie Zhang, Chuanbao Li, Yilong Zhao, Haijian Cheng, Fei Yu, Songlin Wang, Mo Chen, Wenxiang PLoS One Research Article BACKGROUND: The measurement of cardiac troponin is crucial in the diagnosis of myocardial infarction. The performance of troponin measurement is most conveniently monitored by external quality assessment (EQA) programs. The commutability of EQA samples is often unknown and the effectiveness of EQA programs is limited. METHODS: Commutability of possible EQA materials was evaluated. Commercial control materials used in an EQA program, human serum pools prepared from patient samples, purified analyte preparations, swine sera from model animals and a set of patient samples were measured for cTnI with 4 assays including Abbott Architect, Beckman Access, Ortho Vitros and Siemens Centaur. The measurement results were logarithm-transformed, and the transformed data for patient samples were pairwise analyzed with Deming regression and 95% prediction intervals were calculated for each pair of assays. The commutability of the materials was evaluated by comparing the logarithmic results of the materials with the limits of the intervals. Matrix-related biases were estimated for noncommutable materials. The impact of matrix-related bias on EQA was analyzed and a possible correction for the bias was proposed. RESULTS: Human serum pools were commutable for all assays; purified analyte preparations were commutable for 2 of the 6 assay pairs; commercial control materials and swine sera were all noncommutable; swine sera showed no reactivity to Vitros assay. The matrix-related biases for noncommutable materials ranged from −83% to 944%. Matrix-related biases of the EQA materials caused major abnormal between-assay variations in the EQA program and correction of the biases normalized the variations. CONCLUSION: Commutability of materials has major impact on the effectiveness of EQA programs for cTnI measurement. Human serum pools prepared from patient samples are commutable and other materials are mostly noncommutable. EQA programs should include at least one human serum pool to allow proper interpretation of EQA results. Public Library of Science 2014-07-07 /pmc/articles/PMC4085021/ /pubmed/25000586 http://dx.doi.org/10.1371/journal.pone.0102046 Text en © 2014 Zhang et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Zhang, Shunli
Zeng, Jie
Zhang, Chuanbao
Li, Yilong
Zhao, Haijian
Cheng, Fei
Yu, Songlin
Wang, Mo
Chen, Wenxiang
Commutability of Possible External Quality Assessment Materials for Cardiac Troponin Measurement
title Commutability of Possible External Quality Assessment Materials for Cardiac Troponin Measurement
title_full Commutability of Possible External Quality Assessment Materials for Cardiac Troponin Measurement
title_fullStr Commutability of Possible External Quality Assessment Materials for Cardiac Troponin Measurement
title_full_unstemmed Commutability of Possible External Quality Assessment Materials for Cardiac Troponin Measurement
title_short Commutability of Possible External Quality Assessment Materials for Cardiac Troponin Measurement
title_sort commutability of possible external quality assessment materials for cardiac troponin measurement
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4085021/
https://www.ncbi.nlm.nih.gov/pubmed/25000586
http://dx.doi.org/10.1371/journal.pone.0102046
work_keys_str_mv AT zhangshunli commutabilityofpossibleexternalqualityassessmentmaterialsforcardiactroponinmeasurement
AT zengjie commutabilityofpossibleexternalqualityassessmentmaterialsforcardiactroponinmeasurement
AT zhangchuanbao commutabilityofpossibleexternalqualityassessmentmaterialsforcardiactroponinmeasurement
AT liyilong commutabilityofpossibleexternalqualityassessmentmaterialsforcardiactroponinmeasurement
AT zhaohaijian commutabilityofpossibleexternalqualityassessmentmaterialsforcardiactroponinmeasurement
AT chengfei commutabilityofpossibleexternalqualityassessmentmaterialsforcardiactroponinmeasurement
AT yusonglin commutabilityofpossibleexternalqualityassessmentmaterialsforcardiactroponinmeasurement
AT wangmo commutabilityofpossibleexternalqualityassessmentmaterialsforcardiactroponinmeasurement
AT chenwenxiang commutabilityofpossibleexternalqualityassessmentmaterialsforcardiactroponinmeasurement