PURPOSE: The aim of this study was to measure the changes on the marginal and internal adaptation of zirconia based anterior fixed partial dentures after the porcelain firing process. MATERIALS AND METHODS: A total of 34 anterior fixed partial dentures using LAVA CAD/CAM system (3M ESPE, Germany) we...

Descripción completa

Detalles Bibliográficos
Autores principales: Bugurman, Bugurman Burcu, Turker, Sebnem Begum
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Prosthodontics 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4085241/
https://www.ncbi.nlm.nih.gov/pubmed/25006381
http://dx.doi.org/10.4047/jap.2014.6.3.177
_version_ 1782324627966525440
author Bugurman, Bugurman Burcu
Turker, Sebnem Begum
author_facet Bugurman, Bugurman Burcu
Turker, Sebnem Begum
author_sort Bugurman, Bugurman Burcu
collection PubMed
description PURPOSE: The aim of this study was to measure the changes on the marginal and internal adaptation of zirconia based anterior fixed partial dentures after the porcelain firing process. MATERIALS AND METHODS: A total of 34 anterior fixed partial dentures using LAVA CAD/CAM system (3M ESPE, Germany) were applied. Two silicone replicas were obtained: one is obtained before porcelain firing process (initial) and the other is obtained after porcelain firing process (final), followed by the examination under a binocular stereomicroscope. Kruskal Wallis and Wilcoxon Signed Ranks tests were used for the statistical analysis (P<.05). RESULTS: No statistically significant difference was found between initial and final marginal gap values (P>.05). At the internal gap measurements, final marginal area values (59.54 µm) were significantly lower than the initial marginal area values (68.68 µm)(P<.05). The highest and the lowest internal gap values were observed at the incisal/occlusal area and at the marginal area, respectively. In addition, lower internal gap values were obtained for canines than for central incisors, lateral incisors and premolars at the incisal area (P<.05). CONCLUSION: The firing cycles did not affect the marginal gap of Lava CAD/CAM system, but it is controversial for the internal gap.
format Online
Article
Text
id pubmed-4085241
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher The Korean Academy of Prosthodontics
record_format MEDLINE/PubMed
spelling pubmed-40852412014-07-08 Clinical gap changes after porcelain firing cycles of zirconia fixed dentures Bugurman, Bugurman Burcu Turker, Sebnem Begum J Adv Prosthodont Original Article PURPOSE: The aim of this study was to measure the changes on the marginal and internal adaptation of zirconia based anterior fixed partial dentures after the porcelain firing process. MATERIALS AND METHODS: A total of 34 anterior fixed partial dentures using LAVA CAD/CAM system (3M ESPE, Germany) were applied. Two silicone replicas were obtained: one is obtained before porcelain firing process (initial) and the other is obtained after porcelain firing process (final), followed by the examination under a binocular stereomicroscope. Kruskal Wallis and Wilcoxon Signed Ranks tests were used for the statistical analysis (P<.05). RESULTS: No statistically significant difference was found between initial and final marginal gap values (P>.05). At the internal gap measurements, final marginal area values (59.54 µm) were significantly lower than the initial marginal area values (68.68 µm)(P<.05). The highest and the lowest internal gap values were observed at the incisal/occlusal area and at the marginal area, respectively. In addition, lower internal gap values were obtained for canines than for central incisors, lateral incisors and premolars at the incisal area (P<.05). CONCLUSION: The firing cycles did not affect the marginal gap of Lava CAD/CAM system, but it is controversial for the internal gap. The Korean Academy of Prosthodontics 2014-06 2014-06-24 /pmc/articles/PMC4085241/ /pubmed/25006381 http://dx.doi.org/10.4047/jap.2014.6.3.177 Text en © 2014 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Bugurman, Bugurman Burcu
Turker, Sebnem Begum
Clinical gap changes after porcelain firing cycles of zirconia fixed dentures
title Clinical gap changes after porcelain firing cycles of zirconia fixed dentures
title_full Clinical gap changes after porcelain firing cycles of zirconia fixed dentures
title_fullStr Clinical gap changes after porcelain firing cycles of zirconia fixed dentures
title_full_unstemmed Clinical gap changes after porcelain firing cycles of zirconia fixed dentures
title_short Clinical gap changes after porcelain firing cycles of zirconia fixed dentures
title_sort clinical gap changes after porcelain firing cycles of zirconia fixed dentures
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4085241/
https://www.ncbi.nlm.nih.gov/pubmed/25006381
http://dx.doi.org/10.4047/jap.2014.6.3.177
work_keys_str_mv AT bugurmanbugurmanburcu clinicalgapchangesafterporcelainfiringcyclesofzirconiafixeddentures
AT turkersebnembegum clinicalgapchangesafterporcelainfiringcyclesofzirconiafixeddentures