Evaluation of removal forces of implant-supported zirconia copings depending on abutment geometry, luting agent and cleaning method during re-cementation

PURPOSE: To evaluate the effects of different abutment geometries in combination with varying luting agents and the effectiveness of different cleaning methods (prior to re-cementation) regarding the retentiveness of zirconia copings on implants. MATERIALS AND METHODS: Implants were embedded in resi...

Descripción completa

Detalles Bibliográficos
Autores principales: Rödiger, Matthias, Rinke, Sven, Ehret-Kleinau, Fenja, Pohlmeyer, Franziska, Lange, Katharina, Bürgers, Ralf, Gersdorff, Nikolaus
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Prosthodontics 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4085248/
https://www.ncbi.nlm.nih.gov/pubmed/25006388
http://dx.doi.org/10.4047/jap.2014.6.3.233
_version_ 1782324629579235328
author Rödiger, Matthias
Rinke, Sven
Ehret-Kleinau, Fenja
Pohlmeyer, Franziska
Lange, Katharina
Bürgers, Ralf
Gersdorff, Nikolaus
author_facet Rödiger, Matthias
Rinke, Sven
Ehret-Kleinau, Fenja
Pohlmeyer, Franziska
Lange, Katharina
Bürgers, Ralf
Gersdorff, Nikolaus
author_sort Rödiger, Matthias
collection PubMed
description PURPOSE: To evaluate the effects of different abutment geometries in combination with varying luting agents and the effectiveness of different cleaning methods (prior to re-cementation) regarding the retentiveness of zirconia copings on implants. MATERIALS AND METHODS: Implants were embedded in resin blocks. Three groups of titanium abutments (pre-fabricated, height: 7.5 mm, taper: 5.7°; customized-long, height: 6.79 mm, taper: 4.8°; customized-short, height: 4.31 mm, taper: 4.8°) were used for luting of CAD/CAM-fabricated zirconia copings with a semi-permanent (Telio CS) and a provisional cement (TempBond NE). Retention forces were evaluated using a universal testing machine. Furthermore, the influence of cleaning methods (manually, manually in combination with ultrasonic bath or sandblasting) prior to re-cementation with a provisional cement (TempBond NE) was investigated with the pre-fabricated titanium abutments (height: 7.5 mm, taper: 5.7°) and SEM-analysis of inner surfaces of the copings was performed. Significant differences were determined via two-way ANOVA. RESULTS: Significant interactions between abutment geometry and luting agent were observed. TempBond NE showed the highest level of retentiveness on customized-long abutments, but was negatively affected by other abutment geometries. In contrast, luting with Telio CS demonstrated consistent results irrespective of the varying abutment geometries. Manual cleaning in combination with an ultrasonic bath was the only cleaning method tested prior to re-cementation that revealed retentiveness levels not inferior to primary cementation. CONCLUSION: No superiority for one of the two cements could be demonstrated because their influences on retentive strength are also depending on abutment geometry. Only manual cleaning in combination with an ultrasonic bath offers retentiveness levels after re-cementation comparable to those of primary luting.
format Online
Article
Text
id pubmed-4085248
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher The Korean Academy of Prosthodontics
record_format MEDLINE/PubMed
spelling pubmed-40852482014-07-08 Evaluation of removal forces of implant-supported zirconia copings depending on abutment geometry, luting agent and cleaning method during re-cementation Rödiger, Matthias Rinke, Sven Ehret-Kleinau, Fenja Pohlmeyer, Franziska Lange, Katharina Bürgers, Ralf Gersdorff, Nikolaus J Adv Prosthodont Original Article PURPOSE: To evaluate the effects of different abutment geometries in combination with varying luting agents and the effectiveness of different cleaning methods (prior to re-cementation) regarding the retentiveness of zirconia copings on implants. MATERIALS AND METHODS: Implants were embedded in resin blocks. Three groups of titanium abutments (pre-fabricated, height: 7.5 mm, taper: 5.7°; customized-long, height: 6.79 mm, taper: 4.8°; customized-short, height: 4.31 mm, taper: 4.8°) were used for luting of CAD/CAM-fabricated zirconia copings with a semi-permanent (Telio CS) and a provisional cement (TempBond NE). Retention forces were evaluated using a universal testing machine. Furthermore, the influence of cleaning methods (manually, manually in combination with ultrasonic bath or sandblasting) prior to re-cementation with a provisional cement (TempBond NE) was investigated with the pre-fabricated titanium abutments (height: 7.5 mm, taper: 5.7°) and SEM-analysis of inner surfaces of the copings was performed. Significant differences were determined via two-way ANOVA. RESULTS: Significant interactions between abutment geometry and luting agent were observed. TempBond NE showed the highest level of retentiveness on customized-long abutments, but was negatively affected by other abutment geometries. In contrast, luting with Telio CS demonstrated consistent results irrespective of the varying abutment geometries. Manual cleaning in combination with an ultrasonic bath was the only cleaning method tested prior to re-cementation that revealed retentiveness levels not inferior to primary cementation. CONCLUSION: No superiority for one of the two cements could be demonstrated because their influences on retentive strength are also depending on abutment geometry. Only manual cleaning in combination with an ultrasonic bath offers retentiveness levels after re-cementation comparable to those of primary luting. The Korean Academy of Prosthodontics 2014-06 2014-06-24 /pmc/articles/PMC4085248/ /pubmed/25006388 http://dx.doi.org/10.4047/jap.2014.6.3.233 Text en © 2014 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Rödiger, Matthias
Rinke, Sven
Ehret-Kleinau, Fenja
Pohlmeyer, Franziska
Lange, Katharina
Bürgers, Ralf
Gersdorff, Nikolaus
Evaluation of removal forces of implant-supported zirconia copings depending on abutment geometry, luting agent and cleaning method during re-cementation
title Evaluation of removal forces of implant-supported zirconia copings depending on abutment geometry, luting agent and cleaning method during re-cementation
title_full Evaluation of removal forces of implant-supported zirconia copings depending on abutment geometry, luting agent and cleaning method during re-cementation
title_fullStr Evaluation of removal forces of implant-supported zirconia copings depending on abutment geometry, luting agent and cleaning method during re-cementation
title_full_unstemmed Evaluation of removal forces of implant-supported zirconia copings depending on abutment geometry, luting agent and cleaning method during re-cementation
title_short Evaluation of removal forces of implant-supported zirconia copings depending on abutment geometry, luting agent and cleaning method during re-cementation
title_sort evaluation of removal forces of implant-supported zirconia copings depending on abutment geometry, luting agent and cleaning method during re-cementation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4085248/
https://www.ncbi.nlm.nih.gov/pubmed/25006388
http://dx.doi.org/10.4047/jap.2014.6.3.233
work_keys_str_mv AT rodigermatthias evaluationofremovalforcesofimplantsupportedzirconiacopingsdependingonabutmentgeometrylutingagentandcleaningmethodduringrecementation
AT rinkesven evaluationofremovalforcesofimplantsupportedzirconiacopingsdependingonabutmentgeometrylutingagentandcleaningmethodduringrecementation
AT ehretkleinaufenja evaluationofremovalforcesofimplantsupportedzirconiacopingsdependingonabutmentgeometrylutingagentandcleaningmethodduringrecementation
AT pohlmeyerfranziska evaluationofremovalforcesofimplantsupportedzirconiacopingsdependingonabutmentgeometrylutingagentandcleaningmethodduringrecementation
AT langekatharina evaluationofremovalforcesofimplantsupportedzirconiacopingsdependingonabutmentgeometrylutingagentandcleaningmethodduringrecementation
AT burgersralf evaluationofremovalforcesofimplantsupportedzirconiacopingsdependingonabutmentgeometrylutingagentandcleaningmethodduringrecementation
AT gersdorffnikolaus evaluationofremovalforcesofimplantsupportedzirconiacopingsdependingonabutmentgeometrylutingagentandcleaningmethodduringrecementation