Cargando…

Personalized predictive lung dosimetry by technetium-99m macroaggregated albumin SPECT/CT for yttrium-90 radioembolization

BACKGROUND: For yttrium-90 ((90)Y) radioembolization, the common practice of assuming a standard 1,000-g lung mass for predictive dosimetry is fundamentally incongruent with the modern philosophy of personalized medicine. We recently developed a technique of personalized predictive lung dosimetry us...

Descripción completa

Detalles Bibliográficos
Autores principales: Kao, Yung Hsiang, Magsombol, Butch M, Toh, Ying, Tay, Kiang Hiong, Chow, Pierce KH, Goh, Anthony SW, Ng, David CE
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4086353/
https://www.ncbi.nlm.nih.gov/pubmed/25024931
http://dx.doi.org/10.1186/s13550-014-0033-7
_version_ 1782324802138144768
author Kao, Yung Hsiang
Magsombol, Butch M
Toh, Ying
Tay, Kiang Hiong
Chow, Pierce KH
Goh, Anthony SW
Ng, David CE
author_facet Kao, Yung Hsiang
Magsombol, Butch M
Toh, Ying
Tay, Kiang Hiong
Chow, Pierce KH
Goh, Anthony SW
Ng, David CE
author_sort Kao, Yung Hsiang
collection PubMed
description BACKGROUND: For yttrium-90 ((90)Y) radioembolization, the common practice of assuming a standard 1,000-g lung mass for predictive dosimetry is fundamentally incongruent with the modern philosophy of personalized medicine. We recently developed a technique of personalized predictive lung dosimetry using technetium-99m ((99m)Tc) macroaggregated albumin (MAA) single photon emission computed tomography with integrated CT (SPECT/CT) of the lung as part of our routine dosimetric protocol for (90)Y radioembolization. Its rationales are the technical superiority of SPECT/CT over planar scintigraphy, ease and convenience of lung auto-segmentation CT densitovolumetry, and dosimetric advantage of patient-specific lung parenchyma masses. METHODS: This is a retrospective study of our pulmonary clinical outcomes and comparison of lung dosimetric accuracy and precision by (99m)Tc MAA SPECT/CT versus conventional planar methodology. (90)Y resin microspheres (SIR-Spheres) were used for radioembolization. Diagnostic CT densitovolumetry was used as a reference for lung parenchyma mass. Pulmonary outcomes were based on follow-up diagnostic CT chest or X-ray. RESULTS: Thirty patients were analyzed. The mean lung parenchyma mass of our Southeast Asian cohort was 822 ± 103 g standard deviation (95% confidence interval 785 to 859 g). Patient-specific lung parenchyma mass estimation by CT densitovolumetry on (99m)Tc MAA SPECT/CT is accurate (bias −21.7 g) and moderately precise (95% limits of agreement −194.6 to +151.2 g). Lung mean radiation absorbed doses calculated by (99m)Tc MAA SPECT/CT and planar methodology are both accurate (bias <0.5 Gy), but (99m)Tc MAA SPECT/CT offers better precision over planar methodology (95% limits of agreement −1.76 to +2.40 Gy versus −3.48 to +3.31 Gy, respectively). None developed radiomicrosphere pneumonitis when treated up to a lung mean radiation absorbed dose of 18 Gy at a median follow-up of 4.4 months. CONCLUSIONS: Personalized predictive lung dosimetry by (99m)Tc MAA SPECT/CT is clinically feasible, safe, and more precise than conventional planar methodology for (90)Y radioembolization radiation planning.
format Online
Article
Text
id pubmed-4086353
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Springer
record_format MEDLINE/PubMed
spelling pubmed-40863532014-07-14 Personalized predictive lung dosimetry by technetium-99m macroaggregated albumin SPECT/CT for yttrium-90 radioembolization Kao, Yung Hsiang Magsombol, Butch M Toh, Ying Tay, Kiang Hiong Chow, Pierce KH Goh, Anthony SW Ng, David CE EJNMMI Res Original Research BACKGROUND: For yttrium-90 ((90)Y) radioembolization, the common practice of assuming a standard 1,000-g lung mass for predictive dosimetry is fundamentally incongruent with the modern philosophy of personalized medicine. We recently developed a technique of personalized predictive lung dosimetry using technetium-99m ((99m)Tc) macroaggregated albumin (MAA) single photon emission computed tomography with integrated CT (SPECT/CT) of the lung as part of our routine dosimetric protocol for (90)Y radioembolization. Its rationales are the technical superiority of SPECT/CT over planar scintigraphy, ease and convenience of lung auto-segmentation CT densitovolumetry, and dosimetric advantage of patient-specific lung parenchyma masses. METHODS: This is a retrospective study of our pulmonary clinical outcomes and comparison of lung dosimetric accuracy and precision by (99m)Tc MAA SPECT/CT versus conventional planar methodology. (90)Y resin microspheres (SIR-Spheres) were used for radioembolization. Diagnostic CT densitovolumetry was used as a reference for lung parenchyma mass. Pulmonary outcomes were based on follow-up diagnostic CT chest or X-ray. RESULTS: Thirty patients were analyzed. The mean lung parenchyma mass of our Southeast Asian cohort was 822 ± 103 g standard deviation (95% confidence interval 785 to 859 g). Patient-specific lung parenchyma mass estimation by CT densitovolumetry on (99m)Tc MAA SPECT/CT is accurate (bias −21.7 g) and moderately precise (95% limits of agreement −194.6 to +151.2 g). Lung mean radiation absorbed doses calculated by (99m)Tc MAA SPECT/CT and planar methodology are both accurate (bias <0.5 Gy), but (99m)Tc MAA SPECT/CT offers better precision over planar methodology (95% limits of agreement −1.76 to +2.40 Gy versus −3.48 to +3.31 Gy, respectively). None developed radiomicrosphere pneumonitis when treated up to a lung mean radiation absorbed dose of 18 Gy at a median follow-up of 4.4 months. CONCLUSIONS: Personalized predictive lung dosimetry by (99m)Tc MAA SPECT/CT is clinically feasible, safe, and more precise than conventional planar methodology for (90)Y radioembolization radiation planning. Springer 2014-06-29 /pmc/articles/PMC4086353/ /pubmed/25024931 http://dx.doi.org/10.1186/s13550-014-0033-7 Text en Copyright © 2014 Kao et al.; licensee Springer http://creativecommons.org/licenses/by/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited.
spellingShingle Original Research
Kao, Yung Hsiang
Magsombol, Butch M
Toh, Ying
Tay, Kiang Hiong
Chow, Pierce KH
Goh, Anthony SW
Ng, David CE
Personalized predictive lung dosimetry by technetium-99m macroaggregated albumin SPECT/CT for yttrium-90 radioembolization
title Personalized predictive lung dosimetry by technetium-99m macroaggregated albumin SPECT/CT for yttrium-90 radioembolization
title_full Personalized predictive lung dosimetry by technetium-99m macroaggregated albumin SPECT/CT for yttrium-90 radioembolization
title_fullStr Personalized predictive lung dosimetry by technetium-99m macroaggregated albumin SPECT/CT for yttrium-90 radioembolization
title_full_unstemmed Personalized predictive lung dosimetry by technetium-99m macroaggregated albumin SPECT/CT for yttrium-90 radioembolization
title_short Personalized predictive lung dosimetry by technetium-99m macroaggregated albumin SPECT/CT for yttrium-90 radioembolization
title_sort personalized predictive lung dosimetry by technetium-99m macroaggregated albumin spect/ct for yttrium-90 radioembolization
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4086353/
https://www.ncbi.nlm.nih.gov/pubmed/25024931
http://dx.doi.org/10.1186/s13550-014-0033-7
work_keys_str_mv AT kaoyunghsiang personalizedpredictivelungdosimetrybytechnetium99mmacroaggregatedalbuminspectctforyttrium90radioembolization
AT magsombolbutchm personalizedpredictivelungdosimetrybytechnetium99mmacroaggregatedalbuminspectctforyttrium90radioembolization
AT tohying personalizedpredictivelungdosimetrybytechnetium99mmacroaggregatedalbuminspectctforyttrium90radioembolization
AT taykianghiong personalizedpredictivelungdosimetrybytechnetium99mmacroaggregatedalbuminspectctforyttrium90radioembolization
AT chowpiercekh personalizedpredictivelungdosimetrybytechnetium99mmacroaggregatedalbuminspectctforyttrium90radioembolization
AT gohanthonysw personalizedpredictivelungdosimetrybytechnetium99mmacroaggregatedalbuminspectctforyttrium90radioembolization
AT ngdavidce personalizedpredictivelungdosimetrybytechnetium99mmacroaggregatedalbuminspectctforyttrium90radioembolization