Cargando…
Determinants of Posterior Corneal Biometric Measurements in a Multi-Ethnic Asian Population
PURPOSE: To describe the corneal and anterior segment determinants of posterior corneal arc length (PCAL) and posterior corneal curvature (PCC). METHODS: Cross-sectional, population-based study of 1069 subjects (1069 eyes) aged 40–80 years, from three major Asian ethnic groups. All underwent anterio...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4090002/ https://www.ncbi.nlm.nih.gov/pubmed/25006679 http://dx.doi.org/10.1371/journal.pone.0101483 |
_version_ | 1782325205988802560 |
---|---|
author | Ang, Marcus Chong, Wesley Huang, Huiqi Wong, Tien Yin He, Ming-Guang Aung, Tin Mehta, Jodhbir S. |
author_facet | Ang, Marcus Chong, Wesley Huang, Huiqi Wong, Tien Yin He, Ming-Guang Aung, Tin Mehta, Jodhbir S. |
author_sort | Ang, Marcus |
collection | PubMed |
description | PURPOSE: To describe the corneal and anterior segment determinants of posterior corneal arc length (PCAL) and posterior corneal curvature (PCC). METHODS: Cross-sectional, population-based study of 1069 subjects (1069 eyes) aged 40–80 years, from three major Asian ethnic groups. All underwent anterior segment optical coherence tomography imaging and analysis with Zhongshan Angle Assessment Program. Our main outcome measures were determinants of PCAL and PCC using adjusted, multivariate linear regression analysis, adjusted for confounders to obtain the estimated marginal means (EMM) with standard error (SE). RESULTS: The overall mean (± SD) of PCC was: 6.51±0.39 mm; and PCAL was: 12.52±0.59 mm. Malays had a relatively longer PCAL (EMM = 12.74 mm, SE = 0.04 mm) than Chinese (EMM = 12.48 mm, SE = 0.03 mm, P<0.001), and Indians (EMM = 12.42 mm, SE = 0.03 mm, P<0.001). Anterior segment parameters had weak-moderate correlations with PCAL, which included: anterior chamber depth (ACD) (r = 0.55, P<0.001), PCC (r = 0.27, P<0.001), anterior corneal curvature (ACC) (r = 0.14, P<0.001) and central corneal thickness (CCT) (r = −0.07, P = 0.023). In multivariate analysis, anterior segment parameters explained only 37.6% of the variance of PCAL, with ACD being the most important determinant (partial R(2) = 0.300; P<0.001). The determinants of PCC included ACC, PCAL and CCT (explaining 72.1% variation of PCC), with ACC being the most important determinant (partial R(2) = 0.683; P<0.001). CONCLUSION: There was moderate correlation of PCAL with ACD, but anterior segment parameters accounted for only a small proportion of the variation in PCAL. The significant differences in PCAL and PCC amongst different Asian ethnic groups suggests that there is a need to consider this factor when planning for anterior segment surgeries such as endothelial keratoplasty. |
format | Online Article Text |
id | pubmed-4090002 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-40900022014-07-14 Determinants of Posterior Corneal Biometric Measurements in a Multi-Ethnic Asian Population Ang, Marcus Chong, Wesley Huang, Huiqi Wong, Tien Yin He, Ming-Guang Aung, Tin Mehta, Jodhbir S. PLoS One Research Article PURPOSE: To describe the corneal and anterior segment determinants of posterior corneal arc length (PCAL) and posterior corneal curvature (PCC). METHODS: Cross-sectional, population-based study of 1069 subjects (1069 eyes) aged 40–80 years, from three major Asian ethnic groups. All underwent anterior segment optical coherence tomography imaging and analysis with Zhongshan Angle Assessment Program. Our main outcome measures were determinants of PCAL and PCC using adjusted, multivariate linear regression analysis, adjusted for confounders to obtain the estimated marginal means (EMM) with standard error (SE). RESULTS: The overall mean (± SD) of PCC was: 6.51±0.39 mm; and PCAL was: 12.52±0.59 mm. Malays had a relatively longer PCAL (EMM = 12.74 mm, SE = 0.04 mm) than Chinese (EMM = 12.48 mm, SE = 0.03 mm, P<0.001), and Indians (EMM = 12.42 mm, SE = 0.03 mm, P<0.001). Anterior segment parameters had weak-moderate correlations with PCAL, which included: anterior chamber depth (ACD) (r = 0.55, P<0.001), PCC (r = 0.27, P<0.001), anterior corneal curvature (ACC) (r = 0.14, P<0.001) and central corneal thickness (CCT) (r = −0.07, P = 0.023). In multivariate analysis, anterior segment parameters explained only 37.6% of the variance of PCAL, with ACD being the most important determinant (partial R(2) = 0.300; P<0.001). The determinants of PCC included ACC, PCAL and CCT (explaining 72.1% variation of PCC), with ACC being the most important determinant (partial R(2) = 0.683; P<0.001). CONCLUSION: There was moderate correlation of PCAL with ACD, but anterior segment parameters accounted for only a small proportion of the variation in PCAL. The significant differences in PCAL and PCC amongst different Asian ethnic groups suggests that there is a need to consider this factor when planning for anterior segment surgeries such as endothelial keratoplasty. Public Library of Science 2014-07-09 /pmc/articles/PMC4090002/ /pubmed/25006679 http://dx.doi.org/10.1371/journal.pone.0101483 Text en © 2014 Ang et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Ang, Marcus Chong, Wesley Huang, Huiqi Wong, Tien Yin He, Ming-Guang Aung, Tin Mehta, Jodhbir S. Determinants of Posterior Corneal Biometric Measurements in a Multi-Ethnic Asian Population |
title | Determinants of Posterior Corneal Biometric Measurements in a Multi-Ethnic Asian Population |
title_full | Determinants of Posterior Corneal Biometric Measurements in a Multi-Ethnic Asian Population |
title_fullStr | Determinants of Posterior Corneal Biometric Measurements in a Multi-Ethnic Asian Population |
title_full_unstemmed | Determinants of Posterior Corneal Biometric Measurements in a Multi-Ethnic Asian Population |
title_short | Determinants of Posterior Corneal Biometric Measurements in a Multi-Ethnic Asian Population |
title_sort | determinants of posterior corneal biometric measurements in a multi-ethnic asian population |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4090002/ https://www.ncbi.nlm.nih.gov/pubmed/25006679 http://dx.doi.org/10.1371/journal.pone.0101483 |
work_keys_str_mv | AT angmarcus determinantsofposteriorcornealbiometricmeasurementsinamultiethnicasianpopulation AT chongwesley determinantsofposteriorcornealbiometricmeasurementsinamultiethnicasianpopulation AT huanghuiqi determinantsofposteriorcornealbiometricmeasurementsinamultiethnicasianpopulation AT wongtienyin determinantsofposteriorcornealbiometricmeasurementsinamultiethnicasianpopulation AT hemingguang determinantsofposteriorcornealbiometricmeasurementsinamultiethnicasianpopulation AT aungtin determinantsofposteriorcornealbiometricmeasurementsinamultiethnicasianpopulation AT mehtajodhbirs determinantsofposteriorcornealbiometricmeasurementsinamultiethnicasianpopulation |