Central Composite Design for Validation of HPTLC Method for Simultaneous Estimation of Olmesartan Medoxomil, Amlodipine Besylate and Hydrochlorothiazide in Tablets
High performance thin layer chromatographic method for simultaneous estimation of olmesartan medoxomil, amlodipine besylate and hydrochlorothiazide was developed and validated as per ICH guidelines. Moreover, robustness testing was performed applying a central composite design with k factor having 2...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4090824/ https://www.ncbi.nlm.nih.gov/pubmed/25035528 |
_version_ | 1782480698683162624 |
---|---|
author | Solanki, Trupti B. Shah, Purvi A. Patel, Kalpana G. |
author_facet | Solanki, Trupti B. Shah, Purvi A. Patel, Kalpana G. |
author_sort | Solanki, Trupti B. |
collection | PubMed |
description | High performance thin layer chromatographic method for simultaneous estimation of olmesartan medoxomil, amlodipine besylate and hydrochlorothiazide was developed and validated as per ICH guidelines. Moreover, robustness testing was performed applying a central composite design with k factor having 2(k) factorial runs, 2k axial experiments and two center points. High performance thin layer chromatographic separation was performed on aluminium plates precoated with silica gel 60F(254) and toluene:chloroform:methanol:acetonitrile:formic acid (2:7:1.8:0.8:0.2% v/v) as optimized mobile phase. The detection wavelength for simultaneous estimation of three drugs was 232nm. The R(f) values for olmesartan medoxomil, amlodipine besylate and hydrochlorthiazide were 0.78, 0.20 and 0.45, respectively. Percent recoveries in terms of accuracy for the marketed formulation was found to be 101.3-104.4, 100.7-104 and 101.5-103.9 for, olmesartan medoxomil, amlodipine besylate and hydrochlorthiazide, respectively. The pooled %relative standard deviation values for repeatability studies and intermediate precision studies was found to be less than 2% for olmesartan medoxomil, amlodipine besylate and hydrochlorthiazide, respectively. All the three factors evaluated in the robustness testing by central composite design were found to have an insignificant effect on the retention factor. However, methanol content in total mobile phase as a factor appeared to have significant effect on robustness, compared to band size and developing distance and hence it is important to be carefully controlled. In summary, a novel, simple, accurate and reproducible high performance thin layer chromatographic method was developed, which would be of use in quality control of these tablets. |
format | Online Article Text |
id | pubmed-4090824 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-40908242014-07-17 Central Composite Design for Validation of HPTLC Method for Simultaneous Estimation of Olmesartan Medoxomil, Amlodipine Besylate and Hydrochlorothiazide in Tablets Solanki, Trupti B. Shah, Purvi A. Patel, Kalpana G. Indian J Pharm Sci Research Paper High performance thin layer chromatographic method for simultaneous estimation of olmesartan medoxomil, amlodipine besylate and hydrochlorothiazide was developed and validated as per ICH guidelines. Moreover, robustness testing was performed applying a central composite design with k factor having 2(k) factorial runs, 2k axial experiments and two center points. High performance thin layer chromatographic separation was performed on aluminium plates precoated with silica gel 60F(254) and toluene:chloroform:methanol:acetonitrile:formic acid (2:7:1.8:0.8:0.2% v/v) as optimized mobile phase. The detection wavelength for simultaneous estimation of three drugs was 232nm. The R(f) values for olmesartan medoxomil, amlodipine besylate and hydrochlorthiazide were 0.78, 0.20 and 0.45, respectively. Percent recoveries in terms of accuracy for the marketed formulation was found to be 101.3-104.4, 100.7-104 and 101.5-103.9 for, olmesartan medoxomil, amlodipine besylate and hydrochlorthiazide, respectively. The pooled %relative standard deviation values for repeatability studies and intermediate precision studies was found to be less than 2% for olmesartan medoxomil, amlodipine besylate and hydrochlorthiazide, respectively. All the three factors evaluated in the robustness testing by central composite design were found to have an insignificant effect on the retention factor. However, methanol content in total mobile phase as a factor appeared to have significant effect on robustness, compared to band size and developing distance and hence it is important to be carefully controlled. In summary, a novel, simple, accurate and reproducible high performance thin layer chromatographic method was developed, which would be of use in quality control of these tablets. Medknow Publications & Media Pvt Ltd 2014 /pmc/articles/PMC4090824/ /pubmed/25035528 Text en Copyright: © Indian Journal of Pharmaceutical Sciences http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Paper Solanki, Trupti B. Shah, Purvi A. Patel, Kalpana G. Central Composite Design for Validation of HPTLC Method for Simultaneous Estimation of Olmesartan Medoxomil, Amlodipine Besylate and Hydrochlorothiazide in Tablets |
title | Central Composite Design for Validation of HPTLC Method for Simultaneous Estimation of Olmesartan Medoxomil, Amlodipine Besylate and Hydrochlorothiazide in Tablets |
title_full | Central Composite Design for Validation of HPTLC Method for Simultaneous Estimation of Olmesartan Medoxomil, Amlodipine Besylate and Hydrochlorothiazide in Tablets |
title_fullStr | Central Composite Design for Validation of HPTLC Method for Simultaneous Estimation of Olmesartan Medoxomil, Amlodipine Besylate and Hydrochlorothiazide in Tablets |
title_full_unstemmed | Central Composite Design for Validation of HPTLC Method for Simultaneous Estimation of Olmesartan Medoxomil, Amlodipine Besylate and Hydrochlorothiazide in Tablets |
title_short | Central Composite Design for Validation of HPTLC Method for Simultaneous Estimation of Olmesartan Medoxomil, Amlodipine Besylate and Hydrochlorothiazide in Tablets |
title_sort | central composite design for validation of hptlc method for simultaneous estimation of olmesartan medoxomil, amlodipine besylate and hydrochlorothiazide in tablets |
topic | Research Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4090824/ https://www.ncbi.nlm.nih.gov/pubmed/25035528 |
work_keys_str_mv | AT solankitruptib centralcompositedesignforvalidationofhptlcmethodforsimultaneousestimationofolmesartanmedoxomilamlodipinebesylateandhydrochlorothiazideintablets AT shahpurvia centralcompositedesignforvalidationofhptlcmethodforsimultaneousestimationofolmesartanmedoxomilamlodipinebesylateandhydrochlorothiazideintablets AT patelkalpanag centralcompositedesignforvalidationofhptlcmethodforsimultaneousestimationofolmesartanmedoxomilamlodipinebesylateandhydrochlorothiazideintablets |