Cargando…

Phasic Changes in Bladder Compliance During Filling Cystometry of the Neurogenic Bladder

OBJECTIVE: To investigate phasic changes during filling cystometry that most accurately represent detrusor properties, regardless of other factors affecting detrusor contractility. METHODS: Seventy-eight patients (59 males, 19 females; mean age, 48.2 years) with spinal cord injuries were enrolled. U...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Soo-Yeon, Ko, Sung Hwa, Shin, Myung Jun, Park, Yeo Jin, Park, Ji Sang, Lee, Ko Eun, Ko, Hyun-Yoon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Academy of Rehabilitation Medicine 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4092174/
https://www.ncbi.nlm.nih.gov/pubmed/25024957
http://dx.doi.org/10.5535/arm.2014.38.3.342
_version_ 1782325460511752192
author Kim, Soo-Yeon
Ko, Sung Hwa
Shin, Myung Jun
Park, Yeo Jin
Park, Ji Sang
Lee, Ko Eun
Ko, Hyun-Yoon
author_facet Kim, Soo-Yeon
Ko, Sung Hwa
Shin, Myung Jun
Park, Yeo Jin
Park, Ji Sang
Lee, Ko Eun
Ko, Hyun-Yoon
author_sort Kim, Soo-Yeon
collection PubMed
description OBJECTIVE: To investigate phasic changes during filling cystometry that most accurately represent detrusor properties, regardless of other factors affecting detrusor contractility. METHODS: Seventy-eight patients (59 males, 19 females; mean age, 48.2 years) with spinal cord injuries were enrolled. Urodynamic studies were performed using a normal saline filling rate of 24 mL/min. We calculated bladder compliance values of the detrusor muscle in each of three filling phase intervals, which divided the filling cystometrogram into three phases referable to the cystometric capacity or maximum cystometric capacity. The three phases were sequentially delineated by reference to the pressure-volume curve reflecting bladder filling. RESULTS: Bladder compliance during the first and second phases of filling cystometry was significantly correlated with overall bladder compliance in overactive detrusors. The highest coefficient of determination (r(2)=0.329) was obtained during the first phase of the pressure-volume curve. Bladder compliance during all three phases was significantly correlated with overall bladder compliance of filling cystometry in underactive detrusors. However, the coefficient of determination was greatest (r(2)=0.529) during the first phase of filling cystometry. CONCLUSION: Phasic bladder compliance during the early filling phase (first filling phase) was the most representative assessment of overall bladder compliance during filling cystometry. Careful determination of early phase filling is important when seeking to acquire reliable urodynamic data on neurogenic bladders.
format Online
Article
Text
id pubmed-4092174
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Korean Academy of Rehabilitation Medicine
record_format MEDLINE/PubMed
spelling pubmed-40921742014-07-14 Phasic Changes in Bladder Compliance During Filling Cystometry of the Neurogenic Bladder Kim, Soo-Yeon Ko, Sung Hwa Shin, Myung Jun Park, Yeo Jin Park, Ji Sang Lee, Ko Eun Ko, Hyun-Yoon Ann Rehabil Med Original Article OBJECTIVE: To investigate phasic changes during filling cystometry that most accurately represent detrusor properties, regardless of other factors affecting detrusor contractility. METHODS: Seventy-eight patients (59 males, 19 females; mean age, 48.2 years) with spinal cord injuries were enrolled. Urodynamic studies were performed using a normal saline filling rate of 24 mL/min. We calculated bladder compliance values of the detrusor muscle in each of three filling phase intervals, which divided the filling cystometrogram into three phases referable to the cystometric capacity or maximum cystometric capacity. The three phases were sequentially delineated by reference to the pressure-volume curve reflecting bladder filling. RESULTS: Bladder compliance during the first and second phases of filling cystometry was significantly correlated with overall bladder compliance in overactive detrusors. The highest coefficient of determination (r(2)=0.329) was obtained during the first phase of the pressure-volume curve. Bladder compliance during all three phases was significantly correlated with overall bladder compliance of filling cystometry in underactive detrusors. However, the coefficient of determination was greatest (r(2)=0.529) during the first phase of filling cystometry. CONCLUSION: Phasic bladder compliance during the early filling phase (first filling phase) was the most representative assessment of overall bladder compliance during filling cystometry. Careful determination of early phase filling is important when seeking to acquire reliable urodynamic data on neurogenic bladders. Korean Academy of Rehabilitation Medicine 2014-06 2014-06-26 /pmc/articles/PMC4092174/ /pubmed/25024957 http://dx.doi.org/10.5535/arm.2014.38.3.342 Text en Copyright © 2014 by Korean Academy of Rehabilitation Medicine http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Kim, Soo-Yeon
Ko, Sung Hwa
Shin, Myung Jun
Park, Yeo Jin
Park, Ji Sang
Lee, Ko Eun
Ko, Hyun-Yoon
Phasic Changes in Bladder Compliance During Filling Cystometry of the Neurogenic Bladder
title Phasic Changes in Bladder Compliance During Filling Cystometry of the Neurogenic Bladder
title_full Phasic Changes in Bladder Compliance During Filling Cystometry of the Neurogenic Bladder
title_fullStr Phasic Changes in Bladder Compliance During Filling Cystometry of the Neurogenic Bladder
title_full_unstemmed Phasic Changes in Bladder Compliance During Filling Cystometry of the Neurogenic Bladder
title_short Phasic Changes in Bladder Compliance During Filling Cystometry of the Neurogenic Bladder
title_sort phasic changes in bladder compliance during filling cystometry of the neurogenic bladder
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4092174/
https://www.ncbi.nlm.nih.gov/pubmed/25024957
http://dx.doi.org/10.5535/arm.2014.38.3.342
work_keys_str_mv AT kimsooyeon phasicchangesinbladdercomplianceduringfillingcystometryoftheneurogenicbladder
AT kosunghwa phasicchangesinbladdercomplianceduringfillingcystometryoftheneurogenicbladder
AT shinmyungjun phasicchangesinbladdercomplianceduringfillingcystometryoftheneurogenicbladder
AT parkyeojin phasicchangesinbladdercomplianceduringfillingcystometryoftheneurogenicbladder
AT parkjisang phasicchangesinbladdercomplianceduringfillingcystometryoftheneurogenicbladder
AT leekoeun phasicchangesinbladdercomplianceduringfillingcystometryoftheneurogenicbladder
AT kohyunyoon phasicchangesinbladdercomplianceduringfillingcystometryoftheneurogenicbladder