Cargando…
Phasic Changes in Bladder Compliance During Filling Cystometry of the Neurogenic Bladder
OBJECTIVE: To investigate phasic changes during filling cystometry that most accurately represent detrusor properties, regardless of other factors affecting detrusor contractility. METHODS: Seventy-eight patients (59 males, 19 females; mean age, 48.2 years) with spinal cord injuries were enrolled. U...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Academy of Rehabilitation Medicine
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4092174/ https://www.ncbi.nlm.nih.gov/pubmed/25024957 http://dx.doi.org/10.5535/arm.2014.38.3.342 |
_version_ | 1782325460511752192 |
---|---|
author | Kim, Soo-Yeon Ko, Sung Hwa Shin, Myung Jun Park, Yeo Jin Park, Ji Sang Lee, Ko Eun Ko, Hyun-Yoon |
author_facet | Kim, Soo-Yeon Ko, Sung Hwa Shin, Myung Jun Park, Yeo Jin Park, Ji Sang Lee, Ko Eun Ko, Hyun-Yoon |
author_sort | Kim, Soo-Yeon |
collection | PubMed |
description | OBJECTIVE: To investigate phasic changes during filling cystometry that most accurately represent detrusor properties, regardless of other factors affecting detrusor contractility. METHODS: Seventy-eight patients (59 males, 19 females; mean age, 48.2 years) with spinal cord injuries were enrolled. Urodynamic studies were performed using a normal saline filling rate of 24 mL/min. We calculated bladder compliance values of the detrusor muscle in each of three filling phase intervals, which divided the filling cystometrogram into three phases referable to the cystometric capacity or maximum cystometric capacity. The three phases were sequentially delineated by reference to the pressure-volume curve reflecting bladder filling. RESULTS: Bladder compliance during the first and second phases of filling cystometry was significantly correlated with overall bladder compliance in overactive detrusors. The highest coefficient of determination (r(2)=0.329) was obtained during the first phase of the pressure-volume curve. Bladder compliance during all three phases was significantly correlated with overall bladder compliance of filling cystometry in underactive detrusors. However, the coefficient of determination was greatest (r(2)=0.529) during the first phase of filling cystometry. CONCLUSION: Phasic bladder compliance during the early filling phase (first filling phase) was the most representative assessment of overall bladder compliance during filling cystometry. Careful determination of early phase filling is important when seeking to acquire reliable urodynamic data on neurogenic bladders. |
format | Online Article Text |
id | pubmed-4092174 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Korean Academy of Rehabilitation Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-40921742014-07-14 Phasic Changes in Bladder Compliance During Filling Cystometry of the Neurogenic Bladder Kim, Soo-Yeon Ko, Sung Hwa Shin, Myung Jun Park, Yeo Jin Park, Ji Sang Lee, Ko Eun Ko, Hyun-Yoon Ann Rehabil Med Original Article OBJECTIVE: To investigate phasic changes during filling cystometry that most accurately represent detrusor properties, regardless of other factors affecting detrusor contractility. METHODS: Seventy-eight patients (59 males, 19 females; mean age, 48.2 years) with spinal cord injuries were enrolled. Urodynamic studies were performed using a normal saline filling rate of 24 mL/min. We calculated bladder compliance values of the detrusor muscle in each of three filling phase intervals, which divided the filling cystometrogram into three phases referable to the cystometric capacity or maximum cystometric capacity. The three phases were sequentially delineated by reference to the pressure-volume curve reflecting bladder filling. RESULTS: Bladder compliance during the first and second phases of filling cystometry was significantly correlated with overall bladder compliance in overactive detrusors. The highest coefficient of determination (r(2)=0.329) was obtained during the first phase of the pressure-volume curve. Bladder compliance during all three phases was significantly correlated with overall bladder compliance of filling cystometry in underactive detrusors. However, the coefficient of determination was greatest (r(2)=0.529) during the first phase of filling cystometry. CONCLUSION: Phasic bladder compliance during the early filling phase (first filling phase) was the most representative assessment of overall bladder compliance during filling cystometry. Careful determination of early phase filling is important when seeking to acquire reliable urodynamic data on neurogenic bladders. Korean Academy of Rehabilitation Medicine 2014-06 2014-06-26 /pmc/articles/PMC4092174/ /pubmed/25024957 http://dx.doi.org/10.5535/arm.2014.38.3.342 Text en Copyright © 2014 by Korean Academy of Rehabilitation Medicine http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Kim, Soo-Yeon Ko, Sung Hwa Shin, Myung Jun Park, Yeo Jin Park, Ji Sang Lee, Ko Eun Ko, Hyun-Yoon Phasic Changes in Bladder Compliance During Filling Cystometry of the Neurogenic Bladder |
title | Phasic Changes in Bladder Compliance During Filling Cystometry of the Neurogenic Bladder |
title_full | Phasic Changes in Bladder Compliance During Filling Cystometry of the Neurogenic Bladder |
title_fullStr | Phasic Changes in Bladder Compliance During Filling Cystometry of the Neurogenic Bladder |
title_full_unstemmed | Phasic Changes in Bladder Compliance During Filling Cystometry of the Neurogenic Bladder |
title_short | Phasic Changes in Bladder Compliance During Filling Cystometry of the Neurogenic Bladder |
title_sort | phasic changes in bladder compliance during filling cystometry of the neurogenic bladder |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4092174/ https://www.ncbi.nlm.nih.gov/pubmed/25024957 http://dx.doi.org/10.5535/arm.2014.38.3.342 |
work_keys_str_mv | AT kimsooyeon phasicchangesinbladdercomplianceduringfillingcystometryoftheneurogenicbladder AT kosunghwa phasicchangesinbladdercomplianceduringfillingcystometryoftheneurogenicbladder AT shinmyungjun phasicchangesinbladdercomplianceduringfillingcystometryoftheneurogenicbladder AT parkyeojin phasicchangesinbladdercomplianceduringfillingcystometryoftheneurogenicbladder AT parkjisang phasicchangesinbladdercomplianceduringfillingcystometryoftheneurogenicbladder AT leekoeun phasicchangesinbladdercomplianceduringfillingcystometryoftheneurogenicbladder AT kohyunyoon phasicchangesinbladdercomplianceduringfillingcystometryoftheneurogenicbladder |