Cargando…

Evaluation of Corneal Deformation Analyzed with Scheimpflug Based Device in Healthy Eyes and Diseased Ones

This study was designed to evaluate the correlation between corneal biomechanical and morphological data in healthy eyes, eyes that underwent myopic photorefractive keratectomy (PRK), keratoconus affected eyes, and keratoconus affected eyes that underwent corneal collagen crosslinking (CCC). Complet...

Descripción completa

Detalles Bibliográficos
Autores principales: Lanza, Michele, Cennamo, Michela, Iaccarino, Stefania, Irregolare, Carlo, Rechichi, Miguel, Bifani, Mario, Gironi Carnevale, Ugo Antonello
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4094850/
https://www.ncbi.nlm.nih.gov/pubmed/25054144
http://dx.doi.org/10.1155/2014/748671
_version_ 1782325906364170240
author Lanza, Michele
Cennamo, Michela
Iaccarino, Stefania
Irregolare, Carlo
Rechichi, Miguel
Bifani, Mario
Gironi Carnevale, Ugo Antonello
author_facet Lanza, Michele
Cennamo, Michela
Iaccarino, Stefania
Irregolare, Carlo
Rechichi, Miguel
Bifani, Mario
Gironi Carnevale, Ugo Antonello
author_sort Lanza, Michele
collection PubMed
description This study was designed to evaluate the correlation between corneal biomechanical and morphological data in healthy eyes, eyes that underwent myopic photorefractive keratectomy (PRK), keratoconus affected eyes, and keratoconus affected eyes that underwent corneal collagen crosslinking (CCC). Complete clinical eye examination of all eyes was followed by tomographic (Pentacam, Oculus, Wetzlar, Germany) and biomechanical (Corvis ST, Oculus, Wetzlar, Germany) evaluation. Differences among Corvis ST (CST) parameters in the different groups have been performed. Linear regression between central corneal thickness (CCT), intraocular pressure (IOP), and anterior corneal curvature measured with Sim'K (KM), versus corneal deformation parameters measured with Corvis ST in the different groups, has been run using SPSS software version 18.0. We evaluated 64 healthy eyes of 64 patients with a mean refractive error of −0.65 ± 1.68 D (measured as spherical equivalent), 17 eyes of 17 patients that underwent myopic PRK for a mean refractive defect of −4.91 ± 2.05 D (measured as spherical equivalent), 16 eyes of 16 patients affected by keratconus (stage 2-3 of Amsler Classification), and 13 eyes of 13 patients affected by keratoconus that underwent CCC. Our data suggest that corneal curvature would have a greater influence on corneal deformation than CCT; in fact KM values are more strongly associated with more CST parameters both about corneal change in shape and both about the corneal ability to come back at original shape.
format Online
Article
Text
id pubmed-4094850
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-40948502014-07-22 Evaluation of Corneal Deformation Analyzed with Scheimpflug Based Device in Healthy Eyes and Diseased Ones Lanza, Michele Cennamo, Michela Iaccarino, Stefania Irregolare, Carlo Rechichi, Miguel Bifani, Mario Gironi Carnevale, Ugo Antonello Biomed Res Int Clinical Study This study was designed to evaluate the correlation between corneal biomechanical and morphological data in healthy eyes, eyes that underwent myopic photorefractive keratectomy (PRK), keratoconus affected eyes, and keratoconus affected eyes that underwent corneal collagen crosslinking (CCC). Complete clinical eye examination of all eyes was followed by tomographic (Pentacam, Oculus, Wetzlar, Germany) and biomechanical (Corvis ST, Oculus, Wetzlar, Germany) evaluation. Differences among Corvis ST (CST) parameters in the different groups have been performed. Linear regression between central corneal thickness (CCT), intraocular pressure (IOP), and anterior corneal curvature measured with Sim'K (KM), versus corneal deformation parameters measured with Corvis ST in the different groups, has been run using SPSS software version 18.0. We evaluated 64 healthy eyes of 64 patients with a mean refractive error of −0.65 ± 1.68 D (measured as spherical equivalent), 17 eyes of 17 patients that underwent myopic PRK for a mean refractive defect of −4.91 ± 2.05 D (measured as spherical equivalent), 16 eyes of 16 patients affected by keratconus (stage 2-3 of Amsler Classification), and 13 eyes of 13 patients affected by keratoconus that underwent CCC. Our data suggest that corneal curvature would have a greater influence on corneal deformation than CCT; in fact KM values are more strongly associated with more CST parameters both about corneal change in shape and both about the corneal ability to come back at original shape. Hindawi Publishing Corporation 2014 2014-06-23 /pmc/articles/PMC4094850/ /pubmed/25054144 http://dx.doi.org/10.1155/2014/748671 Text en Copyright © 2014 Michele Lanza et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Study
Lanza, Michele
Cennamo, Michela
Iaccarino, Stefania
Irregolare, Carlo
Rechichi, Miguel
Bifani, Mario
Gironi Carnevale, Ugo Antonello
Evaluation of Corneal Deformation Analyzed with Scheimpflug Based Device in Healthy Eyes and Diseased Ones
title Evaluation of Corneal Deformation Analyzed with Scheimpflug Based Device in Healthy Eyes and Diseased Ones
title_full Evaluation of Corneal Deformation Analyzed with Scheimpflug Based Device in Healthy Eyes and Diseased Ones
title_fullStr Evaluation of Corneal Deformation Analyzed with Scheimpflug Based Device in Healthy Eyes and Diseased Ones
title_full_unstemmed Evaluation of Corneal Deformation Analyzed with Scheimpflug Based Device in Healthy Eyes and Diseased Ones
title_short Evaluation of Corneal Deformation Analyzed with Scheimpflug Based Device in Healthy Eyes and Diseased Ones
title_sort evaluation of corneal deformation analyzed with scheimpflug based device in healthy eyes and diseased ones
topic Clinical Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4094850/
https://www.ncbi.nlm.nih.gov/pubmed/25054144
http://dx.doi.org/10.1155/2014/748671
work_keys_str_mv AT lanzamichele evaluationofcornealdeformationanalyzedwithscheimpflugbaseddeviceinhealthyeyesanddiseasedones
AT cennamomichela evaluationofcornealdeformationanalyzedwithscheimpflugbaseddeviceinhealthyeyesanddiseasedones
AT iaccarinostefania evaluationofcornealdeformationanalyzedwithscheimpflugbaseddeviceinhealthyeyesanddiseasedones
AT irregolarecarlo evaluationofcornealdeformationanalyzedwithscheimpflugbaseddeviceinhealthyeyesanddiseasedones
AT rechichimiguel evaluationofcornealdeformationanalyzedwithscheimpflugbaseddeviceinhealthyeyesanddiseasedones
AT bifanimario evaluationofcornealdeformationanalyzedwithscheimpflugbaseddeviceinhealthyeyesanddiseasedones
AT gironicarnevaleugoantonello evaluationofcornealdeformationanalyzedwithscheimpflugbaseddeviceinhealthyeyesanddiseasedones