Cargando…
Biological Width around One- and Two-Piece Implants Retrieved from Human Jaws
Several histologic studies regarding peri-implant soft tissues and biological width around dental implants have been done in animals. However, these findings in human peri-implant soft tissues are very scarce. Therefore, the aim of this case series was to compare the biological width around unloaded...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4094864/ https://www.ncbi.nlm.nih.gov/pubmed/25050375 http://dx.doi.org/10.1155/2014/850120 |
_version_ | 1782325909531918336 |
---|---|
author | Judgar, Ricardo Giro, Gabriela Zenobio, Elton Coelho, Paulo G. Feres, Magda Rodrigues, Jose A. Mangano, Carlo Iezzi, Giovanna Piattelli, Adriano Shibli, Jamil Awad |
author_facet | Judgar, Ricardo Giro, Gabriela Zenobio, Elton Coelho, Paulo G. Feres, Magda Rodrigues, Jose A. Mangano, Carlo Iezzi, Giovanna Piattelli, Adriano Shibli, Jamil Awad |
author_sort | Judgar, Ricardo |
collection | PubMed |
description | Several histologic studies regarding peri-implant soft tissues and biological width around dental implants have been done in animals. However, these findings in human peri-implant soft tissues are very scarce. Therefore, the aim of this case series was to compare the biological width around unloaded one- and two-piece implants retrieved from human jaws. Eight partially edentulous patients received 2 test implants in the posterior mandible: one-piece (solid implants that comprise implant and abutment in one piece) and two-piece (external hexagon with a healing abutment) implants. After 4 months of healing, the implants and surrounding tissue were removed for histologic analysis. The retrieved implants showed healthy peri-implant bone and exhibited early stages of maturation. Marginal bone loss, gaps, and fibrous tissue were not present around retrieved specimens. The biologic width dimension ranged between 2.55 ± 0.16 and 3.26 ± 0.15 to one- and two-piece implants, respectively (P < 0.05). This difference was influenced by the connective tissue attachment, while sulcus depth and epithelial junction presented the same dimension for both groups (P > 0.05). Within the limits of this study, it could be shown that two-piece implants resulted in the thickening of the connective tissue attachment, resulting in the increase of the biological width, when compared to one-piece implants. |
format | Online Article Text |
id | pubmed-4094864 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-40948642014-07-21 Biological Width around One- and Two-Piece Implants Retrieved from Human Jaws Judgar, Ricardo Giro, Gabriela Zenobio, Elton Coelho, Paulo G. Feres, Magda Rodrigues, Jose A. Mangano, Carlo Iezzi, Giovanna Piattelli, Adriano Shibli, Jamil Awad Biomed Res Int Clinical Study Several histologic studies regarding peri-implant soft tissues and biological width around dental implants have been done in animals. However, these findings in human peri-implant soft tissues are very scarce. Therefore, the aim of this case series was to compare the biological width around unloaded one- and two-piece implants retrieved from human jaws. Eight partially edentulous patients received 2 test implants in the posterior mandible: one-piece (solid implants that comprise implant and abutment in one piece) and two-piece (external hexagon with a healing abutment) implants. After 4 months of healing, the implants and surrounding tissue were removed for histologic analysis. The retrieved implants showed healthy peri-implant bone and exhibited early stages of maturation. Marginal bone loss, gaps, and fibrous tissue were not present around retrieved specimens. The biologic width dimension ranged between 2.55 ± 0.16 and 3.26 ± 0.15 to one- and two-piece implants, respectively (P < 0.05). This difference was influenced by the connective tissue attachment, while sulcus depth and epithelial junction presented the same dimension for both groups (P > 0.05). Within the limits of this study, it could be shown that two-piece implants resulted in the thickening of the connective tissue attachment, resulting in the increase of the biological width, when compared to one-piece implants. Hindawi Publishing Corporation 2014 2014-06-23 /pmc/articles/PMC4094864/ /pubmed/25050375 http://dx.doi.org/10.1155/2014/850120 Text en Copyright © 2014 Ricardo Judgar et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Clinical Study Judgar, Ricardo Giro, Gabriela Zenobio, Elton Coelho, Paulo G. Feres, Magda Rodrigues, Jose A. Mangano, Carlo Iezzi, Giovanna Piattelli, Adriano Shibli, Jamil Awad Biological Width around One- and Two-Piece Implants Retrieved from Human Jaws |
title | Biological Width around One- and Two-Piece Implants Retrieved from Human Jaws |
title_full | Biological Width around One- and Two-Piece Implants Retrieved from Human Jaws |
title_fullStr | Biological Width around One- and Two-Piece Implants Retrieved from Human Jaws |
title_full_unstemmed | Biological Width around One- and Two-Piece Implants Retrieved from Human Jaws |
title_short | Biological Width around One- and Two-Piece Implants Retrieved from Human Jaws |
title_sort | biological width around one- and two-piece implants retrieved from human jaws |
topic | Clinical Study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4094864/ https://www.ncbi.nlm.nih.gov/pubmed/25050375 http://dx.doi.org/10.1155/2014/850120 |
work_keys_str_mv | AT judgarricardo biologicalwidtharoundoneandtwopieceimplantsretrievedfromhumanjaws AT girogabriela biologicalwidtharoundoneandtwopieceimplantsretrievedfromhumanjaws AT zenobioelton biologicalwidtharoundoneandtwopieceimplantsretrievedfromhumanjaws AT coelhopaulog biologicalwidtharoundoneandtwopieceimplantsretrievedfromhumanjaws AT feresmagda biologicalwidtharoundoneandtwopieceimplantsretrievedfromhumanjaws AT rodriguesjosea biologicalwidtharoundoneandtwopieceimplantsretrievedfromhumanjaws AT manganocarlo biologicalwidtharoundoneandtwopieceimplantsretrievedfromhumanjaws AT iezzigiovanna biologicalwidtharoundoneandtwopieceimplantsretrievedfromhumanjaws AT piattelliadriano biologicalwidtharoundoneandtwopieceimplantsretrievedfromhumanjaws AT shiblijamilawad biologicalwidtharoundoneandtwopieceimplantsretrievedfromhumanjaws |