Cargando…

CT based three dimensional dose-volume evaluations for high-dose rate intracavitary brachytherapy for cervical cancer

BACKGROUND: In this study, high risk clinical target volumes (HR-CTVs) according to GEC-ESTRO guideline were contoured retrospectively based on CT images taken at the time of high-dose rate intracavitary brachytherapy (HDR-ICBT) and correlation between clinical outcome and dose of HR-CTV were analyz...

Descripción completa

Detalles Bibliográficos
Autores principales: Murakami, Naoya, Kasamatsu, Takahiro, Wakita, Akihisa, Nakamura, Satoshi, Okamoto, Hiroyoki, Inaba, Koji, Morota, Madoka, Ito, Yoshinori, Sumi, Minako, Itami, Jun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4099086/
https://www.ncbi.nlm.nih.gov/pubmed/24938757
http://dx.doi.org/10.1186/1471-2407-14-447
Descripción
Sumario:BACKGROUND: In this study, high risk clinical target volumes (HR-CTVs) according to GEC-ESTRO guideline were contoured retrospectively based on CT images taken at the time of high-dose rate intracavitary brachytherapy (HDR-ICBT) and correlation between clinical outcome and dose of HR-CTV were analyzed. METHODS: Our study population consists of 51 patients with cervical cancer (Stages IB-IVA) treated with 50 Gy external beam radiotherapy (EBRT) using central shield combined with 2–5 times of 6 Gy HDR-ICBT with or without weekly cisplatin. Dose calculation was based on Manchester system and prescribed dose of 6 Gy were delivered for point A. CT images taken at the time of each HDR-ICBT were reviewed and HR-CTVs were contoured. Doses were converted to the equivalent dose in 2 Gy (EQD(2)) by applying the linear quadratic model (α/β = 10 Gy). RESULTS: Three-year overall survival, Progression-free survival, and local control rate was 82.4%, 85.3% and 91.7%, respectively. Median cumulative dose of HR-CTV D(90) was 65.0 Gy (52.7-101.7 Gy). Median length from tandem to the most lateral edge of HR-CTV at the first ICBT was 29.2 mm (range, 18.0-51.9 mm). On univariate analysis, both LCR and PFS was significantly favorable in those patients D(90) for HR-CTV was 60 Gy or greater (p = 0.001 and 0.03, respectively). PFS was significantly favorable in those patients maximum length from tandem to edge of HR-CTV at first ICBT was shorter than 3.5 cm (p = 0.042). CONCLUSION: Volume-dose showed a relationship to the clinical outcome in CT based brachytherapy for cervical carcinoma.