Correlation between target volume and electron transport effects affecting heterogeneity corrections in stereotactic body radiotherapy for lung cancer

Recently, stereotactic body radiotherapy (SBRT) for lung cancer is conducted with heterogeneity-corrected treatment plans, as the correction greatly affects the dose delivery to the lung tumor. In this study, the correlation between the planning target volume (PTV) and the dose delivery is investiga...

Descripción completa

Detalles Bibliográficos
Autores principales: Akino, Yuichi, Das, Indra J., Cardenes, Higinia R., Desrosiers, Colleen M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4099989/
https://www.ncbi.nlm.nih.gov/pubmed/24522269
http://dx.doi.org/10.1093/jrr/rrt231
_version_ 1782326589455859712
author Akino, Yuichi
Das, Indra J.
Cardenes, Higinia R.
Desrosiers, Colleen M.
author_facet Akino, Yuichi
Das, Indra J.
Cardenes, Higinia R.
Desrosiers, Colleen M.
author_sort Akino, Yuichi
collection PubMed
description Recently, stereotactic body radiotherapy (SBRT) for lung cancer is conducted with heterogeneity-corrected treatment plans, as the correction greatly affects the dose delivery to the lung tumor. In this study, the correlation between the planning target volume (PTV) and the dose delivery is investigated by separation of the heterogeneity correction effects into photon attenuation and electron transport. Under Institutional Review Board exemption status, 74 patients with lung cancer who were treated with SBRT were retrospectively evaluated. All treatment plans were generated using an anisotropic analytical algorithm (AAA) of an Eclipse (Varian Medical Systems, Palo Alto, CA) treatment planning system. Two additional plans were created using the same treatment parameters (monitor units, beam angles and energy): a plan with no heterogeneity correction (NC), and a plan calculated with a pencil beam convolution algorithm (PBC). Compared with NC, AAA and PBC isocenter doses were on average 13.4% and 21.8% higher, respectively. The differences in the isocenter dose and the dose coverage for 95% of the PTV (D(95%)) between PBC and AAA were correlated logarithmically (ρ = 0.78 and ρ = 0.46, respectively) with PTV. Although D(95%) calculated with AAA was in general 2.9% larger than that for NC, patients with a small PTV showed a negative ΔD(95%) for AAA due to the significant effect of electron transport. The PTV volume shows logarithmic correlation with the effects of the lateral electron transport. These findings indicate that the dosimetric metrics and prescription, especially in clinical trials, should be clearly evaluated in the context of target volume characteristics and with proper heterogeneity correction.
format Online
Article
Text
id pubmed-4099989
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-40999892014-08-12 Correlation between target volume and electron transport effects affecting heterogeneity corrections in stereotactic body radiotherapy for lung cancer Akino, Yuichi Das, Indra J. Cardenes, Higinia R. Desrosiers, Colleen M. J Radiat Res Oncology Recently, stereotactic body radiotherapy (SBRT) for lung cancer is conducted with heterogeneity-corrected treatment plans, as the correction greatly affects the dose delivery to the lung tumor. In this study, the correlation between the planning target volume (PTV) and the dose delivery is investigated by separation of the heterogeneity correction effects into photon attenuation and electron transport. Under Institutional Review Board exemption status, 74 patients with lung cancer who were treated with SBRT were retrospectively evaluated. All treatment plans were generated using an anisotropic analytical algorithm (AAA) of an Eclipse (Varian Medical Systems, Palo Alto, CA) treatment planning system. Two additional plans were created using the same treatment parameters (monitor units, beam angles and energy): a plan with no heterogeneity correction (NC), and a plan calculated with a pencil beam convolution algorithm (PBC). Compared with NC, AAA and PBC isocenter doses were on average 13.4% and 21.8% higher, respectively. The differences in the isocenter dose and the dose coverage for 95% of the PTV (D(95%)) between PBC and AAA were correlated logarithmically (ρ = 0.78 and ρ = 0.46, respectively) with PTV. Although D(95%) calculated with AAA was in general 2.9% larger than that for NC, patients with a small PTV showed a negative ΔD(95%) for AAA due to the significant effect of electron transport. The PTV volume shows logarithmic correlation with the effects of the lateral electron transport. These findings indicate that the dosimetric metrics and prescription, especially in clinical trials, should be clearly evaluated in the context of target volume characteristics and with proper heterogeneity correction. Oxford University Press 2014-07 2014-02-11 /pmc/articles/PMC4099989/ /pubmed/24522269 http://dx.doi.org/10.1093/jrr/rrt231 Text en © The Author 2014. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology. http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Oncology
Akino, Yuichi
Das, Indra J.
Cardenes, Higinia R.
Desrosiers, Colleen M.
Correlation between target volume and electron transport effects affecting heterogeneity corrections in stereotactic body radiotherapy for lung cancer
title Correlation between target volume and electron transport effects affecting heterogeneity corrections in stereotactic body radiotherapy for lung cancer
title_full Correlation between target volume and electron transport effects affecting heterogeneity corrections in stereotactic body radiotherapy for lung cancer
title_fullStr Correlation between target volume and electron transport effects affecting heterogeneity corrections in stereotactic body radiotherapy for lung cancer
title_full_unstemmed Correlation between target volume and electron transport effects affecting heterogeneity corrections in stereotactic body radiotherapy for lung cancer
title_short Correlation between target volume and electron transport effects affecting heterogeneity corrections in stereotactic body radiotherapy for lung cancer
title_sort correlation between target volume and electron transport effects affecting heterogeneity corrections in stereotactic body radiotherapy for lung cancer
topic Oncology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4099989/
https://www.ncbi.nlm.nih.gov/pubmed/24522269
http://dx.doi.org/10.1093/jrr/rrt231
work_keys_str_mv AT akinoyuichi correlationbetweentargetvolumeandelectrontransporteffectsaffectingheterogeneitycorrectionsinstereotacticbodyradiotherapyforlungcancer
AT dasindraj correlationbetweentargetvolumeandelectrontransporteffectsaffectingheterogeneitycorrectionsinstereotacticbodyradiotherapyforlungcancer
AT cardeneshiginiar correlationbetweentargetvolumeandelectrontransporteffectsaffectingheterogeneitycorrectionsinstereotacticbodyradiotherapyforlungcancer
AT desrosierscolleenm correlationbetweentargetvolumeandelectrontransporteffectsaffectingheterogeneitycorrectionsinstereotacticbodyradiotherapyforlungcancer