Cargando…
On Interlayer Stability and High-Cycle Simulator Performance of Diamond-Like Carbon Layers for Articulating Joint Replacements
Diamond like carbon (DLC) coatings have been proven to be an excellent choice for wear reduction in many technical applications. However, for successful adaption to the orthopaedic field, layer performance, stability and adhesion in physiologically relevant setups are crucial and not consistently in...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4100166/ https://www.ncbi.nlm.nih.gov/pubmed/24921709 http://dx.doi.org/10.3390/ijms150610527 |
_version_ | 1782326626240954368 |
---|---|
author | Thorwarth, Kerstin Thorwarth, Götz Figi, Renato Weisse, Bernhard Stiefel, Michael Hauert, Roland |
author_facet | Thorwarth, Kerstin Thorwarth, Götz Figi, Renato Weisse, Bernhard Stiefel, Michael Hauert, Roland |
author_sort | Thorwarth, Kerstin |
collection | PubMed |
description | Diamond like carbon (DLC) coatings have been proven to be an excellent choice for wear reduction in many technical applications. However, for successful adaption to the orthopaedic field, layer performance, stability and adhesion in physiologically relevant setups are crucial and not consistently investigated. In vitro wear testing as well as adequate corrosion tests of interfaces and interlayers are of great importance to verify the long term stability of DLC coated load bearing implants in the human body. DLC coatings were deposited on articulating lumbar spinal disks made of CoCr28Mo6 biomedical implant alloy using a plasma-activated chemical vapor deposition (PACVD) process. As an adhesion promoting interlayer, tantalum films were deposited by magnetron sputtering. Wear tests of coated and uncoated implants were performed in physiological solution up to a maximum of 101 million articulation cycles with an amplitude of ±2° and −3/+6° in successive intervals at a preload of 1200 N. The implants were characterized by gravimetry, inductively coupled plasma optical emission spectrometry (ICP-OES) and cross section scanning electron microscopy (SEM) analysis. It is shown that DLC coated surfaces with uncontaminated tantalum interlayers perform very well and no corrosive or mechanical failure could be observed. This also holds true in tests featuring overload and third-body wear by cortical bone chips present in the bearing pairs. Regarding the interlayer tolerance towards interlayer contamination (oxygen), limits for initiation of potential failure modes were established. It was found that mechanical failure is the most critical aspect and this mode is hypothetically linked to the α-β tantalum phase switch induced by increasing oxygen levels as observed by X-ray diffraction (XRD). It is concluded that DLC coatings are a feasible candidate for near zero wear articulations on implants, potentially even surpassing the performance of ceramic vs. ceramic. |
format | Online Article Text |
id | pubmed-4100166 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-41001662014-07-16 On Interlayer Stability and High-Cycle Simulator Performance of Diamond-Like Carbon Layers for Articulating Joint Replacements Thorwarth, Kerstin Thorwarth, Götz Figi, Renato Weisse, Bernhard Stiefel, Michael Hauert, Roland Int J Mol Sci Article Diamond like carbon (DLC) coatings have been proven to be an excellent choice for wear reduction in many technical applications. However, for successful adaption to the orthopaedic field, layer performance, stability and adhesion in physiologically relevant setups are crucial and not consistently investigated. In vitro wear testing as well as adequate corrosion tests of interfaces and interlayers are of great importance to verify the long term stability of DLC coated load bearing implants in the human body. DLC coatings were deposited on articulating lumbar spinal disks made of CoCr28Mo6 biomedical implant alloy using a plasma-activated chemical vapor deposition (PACVD) process. As an adhesion promoting interlayer, tantalum films were deposited by magnetron sputtering. Wear tests of coated and uncoated implants were performed in physiological solution up to a maximum of 101 million articulation cycles with an amplitude of ±2° and −3/+6° in successive intervals at a preload of 1200 N. The implants were characterized by gravimetry, inductively coupled plasma optical emission spectrometry (ICP-OES) and cross section scanning electron microscopy (SEM) analysis. It is shown that DLC coated surfaces with uncontaminated tantalum interlayers perform very well and no corrosive or mechanical failure could be observed. This also holds true in tests featuring overload and third-body wear by cortical bone chips present in the bearing pairs. Regarding the interlayer tolerance towards interlayer contamination (oxygen), limits for initiation of potential failure modes were established. It was found that mechanical failure is the most critical aspect and this mode is hypothetically linked to the α-β tantalum phase switch induced by increasing oxygen levels as observed by X-ray diffraction (XRD). It is concluded that DLC coatings are a feasible candidate for near zero wear articulations on implants, potentially even surpassing the performance of ceramic vs. ceramic. MDPI 2014-06-11 /pmc/articles/PMC4100166/ /pubmed/24921709 http://dx.doi.org/10.3390/ijms150610527 Text en © 2014 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Thorwarth, Kerstin Thorwarth, Götz Figi, Renato Weisse, Bernhard Stiefel, Michael Hauert, Roland On Interlayer Stability and High-Cycle Simulator Performance of Diamond-Like Carbon Layers for Articulating Joint Replacements |
title | On Interlayer Stability and High-Cycle Simulator Performance of Diamond-Like Carbon Layers for Articulating Joint Replacements |
title_full | On Interlayer Stability and High-Cycle Simulator Performance of Diamond-Like Carbon Layers for Articulating Joint Replacements |
title_fullStr | On Interlayer Stability and High-Cycle Simulator Performance of Diamond-Like Carbon Layers for Articulating Joint Replacements |
title_full_unstemmed | On Interlayer Stability and High-Cycle Simulator Performance of Diamond-Like Carbon Layers for Articulating Joint Replacements |
title_short | On Interlayer Stability and High-Cycle Simulator Performance of Diamond-Like Carbon Layers for Articulating Joint Replacements |
title_sort | on interlayer stability and high-cycle simulator performance of diamond-like carbon layers for articulating joint replacements |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4100166/ https://www.ncbi.nlm.nih.gov/pubmed/24921709 http://dx.doi.org/10.3390/ijms150610527 |
work_keys_str_mv | AT thorwarthkerstin oninterlayerstabilityandhighcyclesimulatorperformanceofdiamondlikecarbonlayersforarticulatingjointreplacements AT thorwarthgotz oninterlayerstabilityandhighcyclesimulatorperformanceofdiamondlikecarbonlayersforarticulatingjointreplacements AT figirenato oninterlayerstabilityandhighcyclesimulatorperformanceofdiamondlikecarbonlayersforarticulatingjointreplacements AT weissebernhard oninterlayerstabilityandhighcyclesimulatorperformanceofdiamondlikecarbonlayersforarticulatingjointreplacements AT stiefelmichael oninterlayerstabilityandhighcyclesimulatorperformanceofdiamondlikecarbonlayersforarticulatingjointreplacements AT hauertroland oninterlayerstabilityandhighcyclesimulatorperformanceofdiamondlikecarbonlayersforarticulatingjointreplacements |