Cargando…
Comparison of warfarin therapy clinical outcomes following implementation of an automated mobile phone-based critical laboratory value text alert system
BACKGROUND: Computerized alert and reminder systems have been widely accepted and applied to various patient care settings, with increasing numbers of clinical laboratories communicating critical laboratory test values to professionals via either manual notification or automated alerting systems/com...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4101312/ https://www.ncbi.nlm.nih.gov/pubmed/25079609 http://dx.doi.org/10.1186/1755-8794-7-S1-S13 |
_version_ | 1782480868943593472 |
---|---|
author | Lin, Shu-Wen Kang, Wen-Yi Lin, Dong-Tsamn Lee, James Chao-Shen Wu, Fe-Lin Lin Chen, Chuen-Liang Tseng, Yufeng J |
author_facet | Lin, Shu-Wen Kang, Wen-Yi Lin, Dong-Tsamn Lee, James Chao-Shen Wu, Fe-Lin Lin Chen, Chuen-Liang Tseng, Yufeng J |
author_sort | Lin, Shu-Wen |
collection | PubMed |
description | BACKGROUND: Computerized alert and reminder systems have been widely accepted and applied to various patient care settings, with increasing numbers of clinical laboratories communicating critical laboratory test values to professionals via either manual notification or automated alerting systems/computerized reminders. Warfarin, an oral anticoagulant, exhibits narrow therapeutic range between treatment response and adverse events. It requires close monitoring of prothrombin time (PT)/international normalized ratio (INR) to ensure patient safety. This study was aimed to evaluate clinical outcomes of patients on warfarin therapy following implementation of a Personal Handy-phone System-based (PHS) alert system capable of generating and delivering text messages to communicate critical PT/INR laboratory results to practitioners' mobile phones in a large tertiary teaching hospital. METHODS: A retrospective analysis was performed comparing patient clinical outcomes and physician prescribing behavior following conversion from a manual laboratory result alert system to an automated system. Clinical outcomes and practitioner responses to both alert systems were compared. Complications to warfarin therapy, warfarin utilization, and PT/INR results were evaluated for both systems, as well as clinician time to read alert messages, time to warfarin therapy modification, and monitoring frequency. RESULTS: No significant differences were detected in major hemorrhage and thromboembolism, warfarin prescribing patterns, PT/INR results, warfarin therapy modification, or monitoring frequency following implementation of the PHS text alert system. In both study periods, approximately 80% of critical results led to warfarin discontinuation or dose reduction. Senior physicians' follow-up response time to critical results was significantly decreased in the PHS alert study period (46.3% responded within 1 day) compared to the manual notification study period (24.7%; P = 0.015). No difference in follow-up response time was detected for junior physicians. CONCLUSIONS: Implementation of an automated PHS-based text alert system did not adversely impact clinical or safety outcomes of patients on warfarin therapy. Approximately 80% immediate recognition of text alerts was achieved. The potential benefits of an automated PHS alert for senior physicians were demonstrated. |
format | Online Article Text |
id | pubmed-4101312 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-41013122014-07-18 Comparison of warfarin therapy clinical outcomes following implementation of an automated mobile phone-based critical laboratory value text alert system Lin, Shu-Wen Kang, Wen-Yi Lin, Dong-Tsamn Lee, James Chao-Shen Wu, Fe-Lin Lin Chen, Chuen-Liang Tseng, Yufeng J BMC Med Genomics Research BACKGROUND: Computerized alert and reminder systems have been widely accepted and applied to various patient care settings, with increasing numbers of clinical laboratories communicating critical laboratory test values to professionals via either manual notification or automated alerting systems/computerized reminders. Warfarin, an oral anticoagulant, exhibits narrow therapeutic range between treatment response and adverse events. It requires close monitoring of prothrombin time (PT)/international normalized ratio (INR) to ensure patient safety. This study was aimed to evaluate clinical outcomes of patients on warfarin therapy following implementation of a Personal Handy-phone System-based (PHS) alert system capable of generating and delivering text messages to communicate critical PT/INR laboratory results to practitioners' mobile phones in a large tertiary teaching hospital. METHODS: A retrospective analysis was performed comparing patient clinical outcomes and physician prescribing behavior following conversion from a manual laboratory result alert system to an automated system. Clinical outcomes and practitioner responses to both alert systems were compared. Complications to warfarin therapy, warfarin utilization, and PT/INR results were evaluated for both systems, as well as clinician time to read alert messages, time to warfarin therapy modification, and monitoring frequency. RESULTS: No significant differences were detected in major hemorrhage and thromboembolism, warfarin prescribing patterns, PT/INR results, warfarin therapy modification, or monitoring frequency following implementation of the PHS text alert system. In both study periods, approximately 80% of critical results led to warfarin discontinuation or dose reduction. Senior physicians' follow-up response time to critical results was significantly decreased in the PHS alert study period (46.3% responded within 1 day) compared to the manual notification study period (24.7%; P = 0.015). No difference in follow-up response time was detected for junior physicians. CONCLUSIONS: Implementation of an automated PHS-based text alert system did not adversely impact clinical or safety outcomes of patients on warfarin therapy. Approximately 80% immediate recognition of text alerts was achieved. The potential benefits of an automated PHS alert for senior physicians were demonstrated. BioMed Central 2014-05-08 /pmc/articles/PMC4101312/ /pubmed/25079609 http://dx.doi.org/10.1186/1755-8794-7-S1-S13 Text en Copyright © 2014 Lin et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Lin, Shu-Wen Kang, Wen-Yi Lin, Dong-Tsamn Lee, James Chao-Shen Wu, Fe-Lin Lin Chen, Chuen-Liang Tseng, Yufeng J Comparison of warfarin therapy clinical outcomes following implementation of an automated mobile phone-based critical laboratory value text alert system |
title | Comparison of warfarin therapy clinical outcomes following implementation of an automated mobile phone-based critical laboratory value text alert system |
title_full | Comparison of warfarin therapy clinical outcomes following implementation of an automated mobile phone-based critical laboratory value text alert system |
title_fullStr | Comparison of warfarin therapy clinical outcomes following implementation of an automated mobile phone-based critical laboratory value text alert system |
title_full_unstemmed | Comparison of warfarin therapy clinical outcomes following implementation of an automated mobile phone-based critical laboratory value text alert system |
title_short | Comparison of warfarin therapy clinical outcomes following implementation of an automated mobile phone-based critical laboratory value text alert system |
title_sort | comparison of warfarin therapy clinical outcomes following implementation of an automated mobile phone-based critical laboratory value text alert system |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4101312/ https://www.ncbi.nlm.nih.gov/pubmed/25079609 http://dx.doi.org/10.1186/1755-8794-7-S1-S13 |
work_keys_str_mv | AT linshuwen comparisonofwarfarintherapyclinicaloutcomesfollowingimplementationofanautomatedmobilephonebasedcriticallaboratoryvaluetextalertsystem AT kangwenyi comparisonofwarfarintherapyclinicaloutcomesfollowingimplementationofanautomatedmobilephonebasedcriticallaboratoryvaluetextalertsystem AT lindongtsamn comparisonofwarfarintherapyclinicaloutcomesfollowingimplementationofanautomatedmobilephonebasedcriticallaboratoryvaluetextalertsystem AT leejameschaoshen comparisonofwarfarintherapyclinicaloutcomesfollowingimplementationofanautomatedmobilephonebasedcriticallaboratoryvaluetextalertsystem AT wufelinlin comparisonofwarfarintherapyclinicaloutcomesfollowingimplementationofanautomatedmobilephonebasedcriticallaboratoryvaluetextalertsystem AT chenchuenliang comparisonofwarfarintherapyclinicaloutcomesfollowingimplementationofanautomatedmobilephonebasedcriticallaboratoryvaluetextalertsystem AT tsengyufengj comparisonofwarfarintherapyclinicaloutcomesfollowingimplementationofanautomatedmobilephonebasedcriticallaboratoryvaluetextalertsystem |