Cargando…

Videofluoroscopic and Manometric Evaluation of Pharyngeal and Upper Esophageal Sphincter Function During Swallowing

BACKGROUND/AIMS: The purpose of this study was to determine important manometric metrics for the analysis of pharyngeal and upper esophageal sphincter (UES) function and to investigate the effect of viscosity and other confounding factors on manometric results. METHODS: Manometric studies were perfo...

Descripción completa

Detalles Bibliográficos
Autores principales: Yoon, Kyung Jae, Park, Jung Ho, Park, Jung Hwan, Jung, Il Seok
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Neurogastroenterology and Motility 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4102160/
https://www.ncbi.nlm.nih.gov/pubmed/24847841
http://dx.doi.org/10.5056/jnm14021
_version_ 1782481021242966016
author Yoon, Kyung Jae
Park, Jung Ho
Park, Jung Hwan
Jung, Il Seok
author_facet Yoon, Kyung Jae
Park, Jung Ho
Park, Jung Hwan
Jung, Il Seok
author_sort Yoon, Kyung Jae
collection PubMed
description BACKGROUND/AIMS: The purpose of this study was to determine important manometric metrics for the analysis of pharyngeal and upper esophageal sphincter (UES) function and to investigate the effect of viscosity and other confounding factors on manometric results. METHODS: Manometric studies were performed on 26 asymptomatic volunteers (12 men and 14 women; age, 19–81 years). The manometric protocol included 5 water swallows (5 mL), 5 barium swallows (5 mL) and 5 yogurt swallows (5 mL). Evaluation of high-resolution manometry parameters including basal pressure of the UES, mesopharyngeal contractile integral (mesopharyngeal CI, mmHg · cm · sec), CI of the hypopharynx and UES (hypopharyngeal CI), relaxation interval of UES, median intrabolus pressure and nadir pressure at UES was performed using MATLAB. RESULTS: Mesopharyngeal CIs for barium and yogurt swallows were significantly lower than those for water swallows (both P < 0.05). Hypopharyngeal CIs for water swallows were significantly lower than those for barium swallows (P = 0.004), and median bolus pressure at UES for barium swallows was significantly higher than that for water and yogurt swallows (both P < 0.05). Furthermore, hypopharyngeal CI and median intrabolus pressure at UES were significantly related to age for 3 swallows (all P < 0.01 and P < 0.05, respectively). A significant negative correlation was also noted between nadir pressure at UES and age for water and yogurt swallows (all P < 0.05). CONCLUSIONS: Manometric measurement of the pharynx and UES varies with respect to viscosity. Moreover, age could be a confounding variable in the interpretation of pharyngeal manometry.
format Online
Article
Text
id pubmed-4102160
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Korean Society of Neurogastroenterology and Motility
record_format MEDLINE/PubMed
spelling pubmed-41021602014-07-18 Videofluoroscopic and Manometric Evaluation of Pharyngeal and Upper Esophageal Sphincter Function During Swallowing Yoon, Kyung Jae Park, Jung Ho Park, Jung Hwan Jung, Il Seok J Neurogastroenterol Motil Original Article BACKGROUND/AIMS: The purpose of this study was to determine important manometric metrics for the analysis of pharyngeal and upper esophageal sphincter (UES) function and to investigate the effect of viscosity and other confounding factors on manometric results. METHODS: Manometric studies were performed on 26 asymptomatic volunteers (12 men and 14 women; age, 19–81 years). The manometric protocol included 5 water swallows (5 mL), 5 barium swallows (5 mL) and 5 yogurt swallows (5 mL). Evaluation of high-resolution manometry parameters including basal pressure of the UES, mesopharyngeal contractile integral (mesopharyngeal CI, mmHg · cm · sec), CI of the hypopharynx and UES (hypopharyngeal CI), relaxation interval of UES, median intrabolus pressure and nadir pressure at UES was performed using MATLAB. RESULTS: Mesopharyngeal CIs for barium and yogurt swallows were significantly lower than those for water swallows (both P < 0.05). Hypopharyngeal CIs for water swallows were significantly lower than those for barium swallows (P = 0.004), and median bolus pressure at UES for barium swallows was significantly higher than that for water and yogurt swallows (both P < 0.05). Furthermore, hypopharyngeal CI and median intrabolus pressure at UES were significantly related to age for 3 swallows (all P < 0.01 and P < 0.05, respectively). A significant negative correlation was also noted between nadir pressure at UES and age for water and yogurt swallows (all P < 0.05). CONCLUSIONS: Manometric measurement of the pharynx and UES varies with respect to viscosity. Moreover, age could be a confounding variable in the interpretation of pharyngeal manometry. Korean Society of Neurogastroenterology and Motility 2014-07 /pmc/articles/PMC4102160/ /pubmed/24847841 http://dx.doi.org/10.5056/jnm14021 Text en ©2014 The Korean Society of Neurogastroenterology and Motility This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Yoon, Kyung Jae
Park, Jung Ho
Park, Jung Hwan
Jung, Il Seok
Videofluoroscopic and Manometric Evaluation of Pharyngeal and Upper Esophageal Sphincter Function During Swallowing
title Videofluoroscopic and Manometric Evaluation of Pharyngeal and Upper Esophageal Sphincter Function During Swallowing
title_full Videofluoroscopic and Manometric Evaluation of Pharyngeal and Upper Esophageal Sphincter Function During Swallowing
title_fullStr Videofluoroscopic and Manometric Evaluation of Pharyngeal and Upper Esophageal Sphincter Function During Swallowing
title_full_unstemmed Videofluoroscopic and Manometric Evaluation of Pharyngeal and Upper Esophageal Sphincter Function During Swallowing
title_short Videofluoroscopic and Manometric Evaluation of Pharyngeal and Upper Esophageal Sphincter Function During Swallowing
title_sort videofluoroscopic and manometric evaluation of pharyngeal and upper esophageal sphincter function during swallowing
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4102160/
https://www.ncbi.nlm.nih.gov/pubmed/24847841
http://dx.doi.org/10.5056/jnm14021
work_keys_str_mv AT yoonkyungjae videofluoroscopicandmanometricevaluationofpharyngealandupperesophagealsphincterfunctionduringswallowing
AT parkjungho videofluoroscopicandmanometricevaluationofpharyngealandupperesophagealsphincterfunctionduringswallowing
AT parkjunghwan videofluoroscopicandmanometricevaluationofpharyngealandupperesophagealsphincterfunctionduringswallowing
AT jungilseok videofluoroscopicandmanometricevaluationofpharyngealandupperesophagealsphincterfunctionduringswallowing