Cargando…
Videofluoroscopic and Manometric Evaluation of Pharyngeal and Upper Esophageal Sphincter Function During Swallowing
BACKGROUND/AIMS: The purpose of this study was to determine important manometric metrics for the analysis of pharyngeal and upper esophageal sphincter (UES) function and to investigate the effect of viscosity and other confounding factors on manometric results. METHODS: Manometric studies were perfo...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Neurogastroenterology and Motility
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4102160/ https://www.ncbi.nlm.nih.gov/pubmed/24847841 http://dx.doi.org/10.5056/jnm14021 |
_version_ | 1782481021242966016 |
---|---|
author | Yoon, Kyung Jae Park, Jung Ho Park, Jung Hwan Jung, Il Seok |
author_facet | Yoon, Kyung Jae Park, Jung Ho Park, Jung Hwan Jung, Il Seok |
author_sort | Yoon, Kyung Jae |
collection | PubMed |
description | BACKGROUND/AIMS: The purpose of this study was to determine important manometric metrics for the analysis of pharyngeal and upper esophageal sphincter (UES) function and to investigate the effect of viscosity and other confounding factors on manometric results. METHODS: Manometric studies were performed on 26 asymptomatic volunteers (12 men and 14 women; age, 19–81 years). The manometric protocol included 5 water swallows (5 mL), 5 barium swallows (5 mL) and 5 yogurt swallows (5 mL). Evaluation of high-resolution manometry parameters including basal pressure of the UES, mesopharyngeal contractile integral (mesopharyngeal CI, mmHg · cm · sec), CI of the hypopharynx and UES (hypopharyngeal CI), relaxation interval of UES, median intrabolus pressure and nadir pressure at UES was performed using MATLAB. RESULTS: Mesopharyngeal CIs for barium and yogurt swallows were significantly lower than those for water swallows (both P < 0.05). Hypopharyngeal CIs for water swallows were significantly lower than those for barium swallows (P = 0.004), and median bolus pressure at UES for barium swallows was significantly higher than that for water and yogurt swallows (both P < 0.05). Furthermore, hypopharyngeal CI and median intrabolus pressure at UES were significantly related to age for 3 swallows (all P < 0.01 and P < 0.05, respectively). A significant negative correlation was also noted between nadir pressure at UES and age for water and yogurt swallows (all P < 0.05). CONCLUSIONS: Manometric measurement of the pharynx and UES varies with respect to viscosity. Moreover, age could be a confounding variable in the interpretation of pharyngeal manometry. |
format | Online Article Text |
id | pubmed-4102160 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Korean Society of Neurogastroenterology and Motility |
record_format | MEDLINE/PubMed |
spelling | pubmed-41021602014-07-18 Videofluoroscopic and Manometric Evaluation of Pharyngeal and Upper Esophageal Sphincter Function During Swallowing Yoon, Kyung Jae Park, Jung Ho Park, Jung Hwan Jung, Il Seok J Neurogastroenterol Motil Original Article BACKGROUND/AIMS: The purpose of this study was to determine important manometric metrics for the analysis of pharyngeal and upper esophageal sphincter (UES) function and to investigate the effect of viscosity and other confounding factors on manometric results. METHODS: Manometric studies were performed on 26 asymptomatic volunteers (12 men and 14 women; age, 19–81 years). The manometric protocol included 5 water swallows (5 mL), 5 barium swallows (5 mL) and 5 yogurt swallows (5 mL). Evaluation of high-resolution manometry parameters including basal pressure of the UES, mesopharyngeal contractile integral (mesopharyngeal CI, mmHg · cm · sec), CI of the hypopharynx and UES (hypopharyngeal CI), relaxation interval of UES, median intrabolus pressure and nadir pressure at UES was performed using MATLAB. RESULTS: Mesopharyngeal CIs for barium and yogurt swallows were significantly lower than those for water swallows (both P < 0.05). Hypopharyngeal CIs for water swallows were significantly lower than those for barium swallows (P = 0.004), and median bolus pressure at UES for barium swallows was significantly higher than that for water and yogurt swallows (both P < 0.05). Furthermore, hypopharyngeal CI and median intrabolus pressure at UES were significantly related to age for 3 swallows (all P < 0.01 and P < 0.05, respectively). A significant negative correlation was also noted between nadir pressure at UES and age for water and yogurt swallows (all P < 0.05). CONCLUSIONS: Manometric measurement of the pharynx and UES varies with respect to viscosity. Moreover, age could be a confounding variable in the interpretation of pharyngeal manometry. Korean Society of Neurogastroenterology and Motility 2014-07 /pmc/articles/PMC4102160/ /pubmed/24847841 http://dx.doi.org/10.5056/jnm14021 Text en ©2014 The Korean Society of Neurogastroenterology and Motility This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Yoon, Kyung Jae Park, Jung Ho Park, Jung Hwan Jung, Il Seok Videofluoroscopic and Manometric Evaluation of Pharyngeal and Upper Esophageal Sphincter Function During Swallowing |
title | Videofluoroscopic and Manometric Evaluation of Pharyngeal and Upper Esophageal Sphincter Function During Swallowing |
title_full | Videofluoroscopic and Manometric Evaluation of Pharyngeal and Upper Esophageal Sphincter Function During Swallowing |
title_fullStr | Videofluoroscopic and Manometric Evaluation of Pharyngeal and Upper Esophageal Sphincter Function During Swallowing |
title_full_unstemmed | Videofluoroscopic and Manometric Evaluation of Pharyngeal and Upper Esophageal Sphincter Function During Swallowing |
title_short | Videofluoroscopic and Manometric Evaluation of Pharyngeal and Upper Esophageal Sphincter Function During Swallowing |
title_sort | videofluoroscopic and manometric evaluation of pharyngeal and upper esophageal sphincter function during swallowing |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4102160/ https://www.ncbi.nlm.nih.gov/pubmed/24847841 http://dx.doi.org/10.5056/jnm14021 |
work_keys_str_mv | AT yoonkyungjae videofluoroscopicandmanometricevaluationofpharyngealandupperesophagealsphincterfunctionduringswallowing AT parkjungho videofluoroscopicandmanometricevaluationofpharyngealandupperesophagealsphincterfunctionduringswallowing AT parkjunghwan videofluoroscopicandmanometricevaluationofpharyngealandupperesophagealsphincterfunctionduringswallowing AT jungilseok videofluoroscopicandmanometricevaluationofpharyngealandupperesophagealsphincterfunctionduringswallowing |