Cargando…

Effect of femoral neck modularity upon the prosthetic range of motion in total hip arthroplasty

In total hip arthroplasty, aseptic loosening and dislocation are associated with not being able to achieve the correct prosthetic component orientation. Femoral neck modularity has been proposed as a solution to this problem by allowing the surgeon to alter either the neck-shaft or version angle of...

Descripción completa

Detalles Bibliográficos
Autores principales: Turley, Glen A., Griffin, Damian R., Williams, Mark A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4102828/
https://www.ncbi.nlm.nih.gov/pubmed/24969948
http://dx.doi.org/10.1007/s11517-014-1171-9
_version_ 1782327073673576448
author Turley, Glen A.
Griffin, Damian R.
Williams, Mark A.
author_facet Turley, Glen A.
Griffin, Damian R.
Williams, Mark A.
author_sort Turley, Glen A.
collection PubMed
description In total hip arthroplasty, aseptic loosening and dislocation are associated with not being able to achieve the correct prosthetic component orientation. Femoral neck modularity has been proposed as a solution to this problem by allowing the surgeon to alter either the neck-shaft or version angle of the prosthetic femoral component intra-operatively. A single replicate full factorial design was used to evaluate how effective a modular femoral neck cementless stem was in restoring a healthy prosthetic range of motion in comparison with a leading fixed-neck cementless stem with the standard modular parameters. It was found that, if altered to a large enough degree, femoral neck modularity can increase the amount of prosthetic motion as well as alter its position to where it is required physiologically. However, there is a functional limit to the amount that can be corrected and there is a risk with regard to the surgeon having to select the optimum modular neck before any benefit is realised. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s11517-014-1171-9) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-4102828
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-41028282014-07-30 Effect of femoral neck modularity upon the prosthetic range of motion in total hip arthroplasty Turley, Glen A. Griffin, Damian R. Williams, Mark A. Med Biol Eng Comput Original Article In total hip arthroplasty, aseptic loosening and dislocation are associated with not being able to achieve the correct prosthetic component orientation. Femoral neck modularity has been proposed as a solution to this problem by allowing the surgeon to alter either the neck-shaft or version angle of the prosthetic femoral component intra-operatively. A single replicate full factorial design was used to evaluate how effective a modular femoral neck cementless stem was in restoring a healthy prosthetic range of motion in comparison with a leading fixed-neck cementless stem with the standard modular parameters. It was found that, if altered to a large enough degree, femoral neck modularity can increase the amount of prosthetic motion as well as alter its position to where it is required physiologically. However, there is a functional limit to the amount that can be corrected and there is a risk with regard to the surgeon having to select the optimum modular neck before any benefit is realised. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s11517-014-1171-9) contains supplementary material, which is available to authorized users. Springer Berlin Heidelberg 2014-06-27 2014 /pmc/articles/PMC4102828/ /pubmed/24969948 http://dx.doi.org/10.1007/s11517-014-1171-9 Text en © The Author(s) 2014 https://creativecommons.org/licenses/by/4.0/ Open AccessThis article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Original Article
Turley, Glen A.
Griffin, Damian R.
Williams, Mark A.
Effect of femoral neck modularity upon the prosthetic range of motion in total hip arthroplasty
title Effect of femoral neck modularity upon the prosthetic range of motion in total hip arthroplasty
title_full Effect of femoral neck modularity upon the prosthetic range of motion in total hip arthroplasty
title_fullStr Effect of femoral neck modularity upon the prosthetic range of motion in total hip arthroplasty
title_full_unstemmed Effect of femoral neck modularity upon the prosthetic range of motion in total hip arthroplasty
title_short Effect of femoral neck modularity upon the prosthetic range of motion in total hip arthroplasty
title_sort effect of femoral neck modularity upon the prosthetic range of motion in total hip arthroplasty
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4102828/
https://www.ncbi.nlm.nih.gov/pubmed/24969948
http://dx.doi.org/10.1007/s11517-014-1171-9
work_keys_str_mv AT turleyglena effectoffemoralneckmodularityupontheprostheticrangeofmotionintotalhiparthroplasty
AT griffindamianr effectoffemoralneckmodularityupontheprostheticrangeofmotionintotalhiparthroplasty
AT williamsmarka effectoffemoralneckmodularityupontheprostheticrangeofmotionintotalhiparthroplasty