Cargando…
Portable high-intensity focused ultrasound system with 3D electronic steering, real-time cavitation monitoring, and 3D image reconstruction algorithms: a preclinical study in pigs
PURPOSE: The aim of this study was to evaluate the safety and accuracy of a new portable ultrasonography-guided high-intensity focused ultrasound (USg-HIFU) system with a 3-dimensional (3D) electronic steering transducer, a simultaneous ablation and imaging module, real-time cavitation monitoring, a...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Ultrasound in Medicine
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4104954/ https://www.ncbi.nlm.nih.gov/pubmed/25038809 http://dx.doi.org/10.14366/usg.14008 |
_version_ | 1782327296593494016 |
---|---|
author | Choi, Jin Woo Lee, Jae Young Hwang, Eui Jin Hwang, Inpyeong Woo, Sungmin Lee, Chang Joo Park, Eun-Joo Choi, Byung Ihn |
author_facet | Choi, Jin Woo Lee, Jae Young Hwang, Eui Jin Hwang, Inpyeong Woo, Sungmin Lee, Chang Joo Park, Eun-Joo Choi, Byung Ihn |
author_sort | Choi, Jin Woo |
collection | PubMed |
description | PURPOSE: The aim of this study was to evaluate the safety and accuracy of a new portable ultrasonography-guided high-intensity focused ultrasound (USg-HIFU) system with a 3-dimensional (3D) electronic steering transducer, a simultaneous ablation and imaging module, real-time cavitation monitoring, and 3D image reconstruction algorithms. METHODS: To address the accuracy of the transducer, hydrophones in a water chamber were used to assess the generation of sonic fields. An animal study was also performed in five pigs by ablating in vivo thighs by single-point sonication (n=10) or volume sonication (n=10) and ex vivo kidneys by single-point sonication (n=10). Histological and statistical analyses were performed. RESULTS: In the hydrophone study, peak voltages were detected within 1.0 mm from the targets on the y- and z-axes and within 2.0-mm intervals along the x-axis (z-axis, direction of ultrasound propagation; y- and x-axes, perpendicular to the direction of ultrasound propagation). Twenty-nine of 30 HIFU sessions successfully created ablations at the target. The in vivo porcine thigh study showed only a small discrepancy (width, 0.5-1.1 mm; length, 3.0 mm) between the planning ultrasonograms and the pathological specimens. Inordinate thermal damage was not observed in the adjacent tissues or sonic pathways in the in vivo thigh and ex vivo kidney studies. CONCLUSION: Our study suggests that this new USg-HIFU system may be a safe and accurate technique for ablating soft tissues and encapsulated organs. |
format | Online Article Text |
id | pubmed-4104954 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Korean Society of Ultrasound in Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-41049542014-07-24 Portable high-intensity focused ultrasound system with 3D electronic steering, real-time cavitation monitoring, and 3D image reconstruction algorithms: a preclinical study in pigs Choi, Jin Woo Lee, Jae Young Hwang, Eui Jin Hwang, Inpyeong Woo, Sungmin Lee, Chang Joo Park, Eun-Joo Choi, Byung Ihn Ultrasonography Original Article PURPOSE: The aim of this study was to evaluate the safety and accuracy of a new portable ultrasonography-guided high-intensity focused ultrasound (USg-HIFU) system with a 3-dimensional (3D) electronic steering transducer, a simultaneous ablation and imaging module, real-time cavitation monitoring, and 3D image reconstruction algorithms. METHODS: To address the accuracy of the transducer, hydrophones in a water chamber were used to assess the generation of sonic fields. An animal study was also performed in five pigs by ablating in vivo thighs by single-point sonication (n=10) or volume sonication (n=10) and ex vivo kidneys by single-point sonication (n=10). Histological and statistical analyses were performed. RESULTS: In the hydrophone study, peak voltages were detected within 1.0 mm from the targets on the y- and z-axes and within 2.0-mm intervals along the x-axis (z-axis, direction of ultrasound propagation; y- and x-axes, perpendicular to the direction of ultrasound propagation). Twenty-nine of 30 HIFU sessions successfully created ablations at the target. The in vivo porcine thigh study showed only a small discrepancy (width, 0.5-1.1 mm; length, 3.0 mm) between the planning ultrasonograms and the pathological specimens. Inordinate thermal damage was not observed in the adjacent tissues or sonic pathways in the in vivo thigh and ex vivo kidney studies. CONCLUSION: Our study suggests that this new USg-HIFU system may be a safe and accurate technique for ablating soft tissues and encapsulated organs. Korean Society of Ultrasound in Medicine 2014-07 2014-03-26 /pmc/articles/PMC4104954/ /pubmed/25038809 http://dx.doi.org/10.14366/usg.14008 Text en Copyright © 2014 Korean Society of Ultrasound in Medicine (KSUM) This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Choi, Jin Woo Lee, Jae Young Hwang, Eui Jin Hwang, Inpyeong Woo, Sungmin Lee, Chang Joo Park, Eun-Joo Choi, Byung Ihn Portable high-intensity focused ultrasound system with 3D electronic steering, real-time cavitation monitoring, and 3D image reconstruction algorithms: a preclinical study in pigs |
title | Portable high-intensity focused ultrasound system with 3D electronic steering, real-time cavitation monitoring, and 3D image reconstruction algorithms: a preclinical study in pigs |
title_full | Portable high-intensity focused ultrasound system with 3D electronic steering, real-time cavitation monitoring, and 3D image reconstruction algorithms: a preclinical study in pigs |
title_fullStr | Portable high-intensity focused ultrasound system with 3D electronic steering, real-time cavitation monitoring, and 3D image reconstruction algorithms: a preclinical study in pigs |
title_full_unstemmed | Portable high-intensity focused ultrasound system with 3D electronic steering, real-time cavitation monitoring, and 3D image reconstruction algorithms: a preclinical study in pigs |
title_short | Portable high-intensity focused ultrasound system with 3D electronic steering, real-time cavitation monitoring, and 3D image reconstruction algorithms: a preclinical study in pigs |
title_sort | portable high-intensity focused ultrasound system with 3d electronic steering, real-time cavitation monitoring, and 3d image reconstruction algorithms: a preclinical study in pigs |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4104954/ https://www.ncbi.nlm.nih.gov/pubmed/25038809 http://dx.doi.org/10.14366/usg.14008 |
work_keys_str_mv | AT choijinwoo portablehighintensityfocusedultrasoundsystemwith3delectronicsteeringrealtimecavitationmonitoringand3dimagereconstructionalgorithmsapreclinicalstudyinpigs AT leejaeyoung portablehighintensityfocusedultrasoundsystemwith3delectronicsteeringrealtimecavitationmonitoringand3dimagereconstructionalgorithmsapreclinicalstudyinpigs AT hwangeuijin portablehighintensityfocusedultrasoundsystemwith3delectronicsteeringrealtimecavitationmonitoringand3dimagereconstructionalgorithmsapreclinicalstudyinpigs AT hwanginpyeong portablehighintensityfocusedultrasoundsystemwith3delectronicsteeringrealtimecavitationmonitoringand3dimagereconstructionalgorithmsapreclinicalstudyinpigs AT woosungmin portablehighintensityfocusedultrasoundsystemwith3delectronicsteeringrealtimecavitationmonitoringand3dimagereconstructionalgorithmsapreclinicalstudyinpigs AT leechangjoo portablehighintensityfocusedultrasoundsystemwith3delectronicsteeringrealtimecavitationmonitoringand3dimagereconstructionalgorithmsapreclinicalstudyinpigs AT parkeunjoo portablehighintensityfocusedultrasoundsystemwith3delectronicsteeringrealtimecavitationmonitoringand3dimagereconstructionalgorithmsapreclinicalstudyinpigs AT choibyungihn portablehighintensityfocusedultrasoundsystemwith3delectronicsteeringrealtimecavitationmonitoringand3dimagereconstructionalgorithmsapreclinicalstudyinpigs |