Cargando…
Comparing a volume based template approach and ultrasound guided freehand approach in multicatheter interstitial accelerated partial breast irradiation
PURPOSE: Currently, there are two described methods of catheter insertion for women undergoing multicatheter interstitial accelerated partial breast irradiation (APBI). These are a volume based template approach (template) and a non-template ultrasound guidance freehand approach (non-template). We a...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Termedia Publishing House
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4105646/ https://www.ncbi.nlm.nih.gov/pubmed/25097558 http://dx.doi.org/10.5114/jcb.2014.43329 |
_version_ | 1782327409525129216 |
---|---|
author | Koh, Vicky Y. Buhari, Shaik A. Tan, Poh Wee Tan, Yun Inn Leong, Yuh Fun Earnest, Arul Tang, Johann I. |
author_facet | Koh, Vicky Y. Buhari, Shaik A. Tan, Poh Wee Tan, Yun Inn Leong, Yuh Fun Earnest, Arul Tang, Johann I. |
author_sort | Koh, Vicky Y. |
collection | PubMed |
description | PURPOSE: Currently, there are two described methods of catheter insertion for women undergoing multicatheter interstitial accelerated partial breast irradiation (APBI). These are a volume based template approach (template) and a non-template ultrasound guidance freehand approach (non-template). We aim to compare dosimetric endpoints between the template and non-template approach. MATERIAL AND METHODS: Twenty patients, who received adjuvant multicatheter interstitial APBI between August 2008 to March 2010 formed the study cohort. Dosimetric planning was based on the RTOG 04-13 protocol. For standardization, the planning target volume evaluation (PTV-Eval) and organs at risk were contoured with the assistance of the attending surgeon. Dosimetric endpoints include D(90) of the PTV-Eval, Dose Homogeneity Index (DHI), V(200), maximum skin dose (MSD), and maximum chest wall dose (MCD). A median of 18 catheters was used per patient. The dose prescribed was 34 Gy in 10 fractions BID over 5 days. RESULTS: The average breast volume was 846 cm(3) (526-1384) for the entire cohort and there was no difference between the two groups (p = 0.6). Insertion time was significantly longer for the non-template approach (mean 150 minutes) compared to the template approach (mean: 90 minutes) (p = 0.02). The planning time was also significantly longer for the non-template approach (mean: 240 minutes) compared to the template approach (mean: 150 minutes) (p < 0.01). The template approach yielded a higher D(90) (mean: 95%) compared to the non-template approach (mean: 92%) (p < 0.01). There were no differences in DHI (p = 0.14), V(200) (p = 0.21), MSD (p = 0.7), and MCD (p = 0.8). CONCLUSIONS: Compared to the non-template approach, the template approach offered significant shorter insertion and planning times with significantly improved dosimetric PTV-Eval coverage without significantly compromising organs at risk dosimetrically. |
format | Online Article Text |
id | pubmed-4105646 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Termedia Publishing House |
record_format | MEDLINE/PubMed |
spelling | pubmed-41056462014-08-05 Comparing a volume based template approach and ultrasound guided freehand approach in multicatheter interstitial accelerated partial breast irradiation Koh, Vicky Y. Buhari, Shaik A. Tan, Poh Wee Tan, Yun Inn Leong, Yuh Fun Earnest, Arul Tang, Johann I. J Contemp Brachytherapy Original Paper PURPOSE: Currently, there are two described methods of catheter insertion for women undergoing multicatheter interstitial accelerated partial breast irradiation (APBI). These are a volume based template approach (template) and a non-template ultrasound guidance freehand approach (non-template). We aim to compare dosimetric endpoints between the template and non-template approach. MATERIAL AND METHODS: Twenty patients, who received adjuvant multicatheter interstitial APBI between August 2008 to March 2010 formed the study cohort. Dosimetric planning was based on the RTOG 04-13 protocol. For standardization, the planning target volume evaluation (PTV-Eval) and organs at risk were contoured with the assistance of the attending surgeon. Dosimetric endpoints include D(90) of the PTV-Eval, Dose Homogeneity Index (DHI), V(200), maximum skin dose (MSD), and maximum chest wall dose (MCD). A median of 18 catheters was used per patient. The dose prescribed was 34 Gy in 10 fractions BID over 5 days. RESULTS: The average breast volume was 846 cm(3) (526-1384) for the entire cohort and there was no difference between the two groups (p = 0.6). Insertion time was significantly longer for the non-template approach (mean 150 minutes) compared to the template approach (mean: 90 minutes) (p = 0.02). The planning time was also significantly longer for the non-template approach (mean: 240 minutes) compared to the template approach (mean: 150 minutes) (p < 0.01). The template approach yielded a higher D(90) (mean: 95%) compared to the non-template approach (mean: 92%) (p < 0.01). There were no differences in DHI (p = 0.14), V(200) (p = 0.21), MSD (p = 0.7), and MCD (p = 0.8). CONCLUSIONS: Compared to the non-template approach, the template approach offered significant shorter insertion and planning times with significantly improved dosimetric PTV-Eval coverage without significantly compromising organs at risk dosimetrically. Termedia Publishing House 2014-06-09 2014-06 /pmc/articles/PMC4105646/ /pubmed/25097558 http://dx.doi.org/10.5114/jcb.2014.43329 Text en Copyright © 2014 Termedia http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial 3.0 Unported License, permitting all non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Paper Koh, Vicky Y. Buhari, Shaik A. Tan, Poh Wee Tan, Yun Inn Leong, Yuh Fun Earnest, Arul Tang, Johann I. Comparing a volume based template approach and ultrasound guided freehand approach in multicatheter interstitial accelerated partial breast irradiation |
title | Comparing a volume based template approach and ultrasound guided freehand approach in multicatheter interstitial accelerated partial breast irradiation |
title_full | Comparing a volume based template approach and ultrasound guided freehand approach in multicatheter interstitial accelerated partial breast irradiation |
title_fullStr | Comparing a volume based template approach and ultrasound guided freehand approach in multicatheter interstitial accelerated partial breast irradiation |
title_full_unstemmed | Comparing a volume based template approach and ultrasound guided freehand approach in multicatheter interstitial accelerated partial breast irradiation |
title_short | Comparing a volume based template approach and ultrasound guided freehand approach in multicatheter interstitial accelerated partial breast irradiation |
title_sort | comparing a volume based template approach and ultrasound guided freehand approach in multicatheter interstitial accelerated partial breast irradiation |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4105646/ https://www.ncbi.nlm.nih.gov/pubmed/25097558 http://dx.doi.org/10.5114/jcb.2014.43329 |
work_keys_str_mv | AT kohvickyy comparingavolumebasedtemplateapproachandultrasoundguidedfreehandapproachinmulticatheterinterstitialacceleratedpartialbreastirradiation AT buharishaika comparingavolumebasedtemplateapproachandultrasoundguidedfreehandapproachinmulticatheterinterstitialacceleratedpartialbreastirradiation AT tanpohwee comparingavolumebasedtemplateapproachandultrasoundguidedfreehandapproachinmulticatheterinterstitialacceleratedpartialbreastirradiation AT tanyuninn comparingavolumebasedtemplateapproachandultrasoundguidedfreehandapproachinmulticatheterinterstitialacceleratedpartialbreastirradiation AT leongyuhfun comparingavolumebasedtemplateapproachandultrasoundguidedfreehandapproachinmulticatheterinterstitialacceleratedpartialbreastirradiation AT earnestarul comparingavolumebasedtemplateapproachandultrasoundguidedfreehandapproachinmulticatheterinterstitialacceleratedpartialbreastirradiation AT tangjohanni comparingavolumebasedtemplateapproachandultrasoundguidedfreehandapproachinmulticatheterinterstitialacceleratedpartialbreastirradiation |