Cargando…

The Accuracy of the New Landmark Using Respiratory Jugular Venodilation and Direct Palpation in Right Internal Jugular Vein Access

BACKGROUND: Although ultrasonography is recommended in internal jugular vein (IJV) catheterization, the landmark-guided technique should still be considered. The central landmark using the two heads of the sternocleidomastoid muscle is widely used, but it is inaccurate for IJV access. As an alternat...

Descripción completa

Detalles Bibliográficos
Autores principales: Seo, Hyungseok, Jang, Dong-Min, Yi, Jung-Min, Min, Hong-Gi, Hwang, Jai-Hyun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4106888/
https://www.ncbi.nlm.nih.gov/pubmed/25050554
http://dx.doi.org/10.1371/journal.pone.0103089
_version_ 1782327549008805888
author Seo, Hyungseok
Jang, Dong-Min
Yi, Jung-Min
Min, Hong-Gi
Hwang, Jai-Hyun
author_facet Seo, Hyungseok
Jang, Dong-Min
Yi, Jung-Min
Min, Hong-Gi
Hwang, Jai-Hyun
author_sort Seo, Hyungseok
collection PubMed
description BACKGROUND: Although ultrasonography is recommended in internal jugular vein (IJV) catheterization, the landmark-guided technique should still be considered. The central landmark using the two heads of the sternocleidomastoid muscle is widely used, but it is inaccurate for IJV access. As an alternative landmark, we investigated the accuracy of the new landmark determined by inspection of the respiratory jugular venodilation and direct IJV palpation in right IJV access by ultrasonography. METHODS AND FINDINGS: Thirty patients were enrolled. After induction of anesthesia, the central landmark was marked at the cricoid cartilage level (M1) and the alternative landmark determined by inspection of the respiratory jugular venodilation and direct palpation of IJV was also marked at the same level (M2). Using ultrasonography, the location of IJV was identified (M3) and the distance between M1 and M3 as well as between M2 and M3 were measured. The median (interquartile range) distance between the M2 and M3 was 3.5 (2.0–6.0) mm, compared to 17.5 (12.8–21.3) mm between M1 and M3. (P<0.001) The dispersion of distances between M2 and M3 was significantly smaller than between M1 and M3. (P<0.001) The visibility of respiratory jugular venodilation was associated with CVP more than 4 mmHg. Limitations of the present study are that the inter-observer variability was not investigated and that the visibility of the alternative landmark can be limited to right IJV in adults. CONCLUSION: The alternative landmark may allow shorter distance for the right side IJV access than the central landmark and can offer advantages in right IJV catheterization when ultrasound device is unavailable. TRIAL REGISTRATION: Clinical Research Informational Service KCT0000812
format Online
Article
Text
id pubmed-4106888
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-41068882014-07-23 The Accuracy of the New Landmark Using Respiratory Jugular Venodilation and Direct Palpation in Right Internal Jugular Vein Access Seo, Hyungseok Jang, Dong-Min Yi, Jung-Min Min, Hong-Gi Hwang, Jai-Hyun PLoS One Research Article BACKGROUND: Although ultrasonography is recommended in internal jugular vein (IJV) catheterization, the landmark-guided technique should still be considered. The central landmark using the two heads of the sternocleidomastoid muscle is widely used, but it is inaccurate for IJV access. As an alternative landmark, we investigated the accuracy of the new landmark determined by inspection of the respiratory jugular venodilation and direct IJV palpation in right IJV access by ultrasonography. METHODS AND FINDINGS: Thirty patients were enrolled. After induction of anesthesia, the central landmark was marked at the cricoid cartilage level (M1) and the alternative landmark determined by inspection of the respiratory jugular venodilation and direct palpation of IJV was also marked at the same level (M2). Using ultrasonography, the location of IJV was identified (M3) and the distance between M1 and M3 as well as between M2 and M3 were measured. The median (interquartile range) distance between the M2 and M3 was 3.5 (2.0–6.0) mm, compared to 17.5 (12.8–21.3) mm between M1 and M3. (P<0.001) The dispersion of distances between M2 and M3 was significantly smaller than between M1 and M3. (P<0.001) The visibility of respiratory jugular venodilation was associated with CVP more than 4 mmHg. Limitations of the present study are that the inter-observer variability was not investigated and that the visibility of the alternative landmark can be limited to right IJV in adults. CONCLUSION: The alternative landmark may allow shorter distance for the right side IJV access than the central landmark and can offer advantages in right IJV catheterization when ultrasound device is unavailable. TRIAL REGISTRATION: Clinical Research Informational Service KCT0000812 Public Library of Science 2014-07-22 /pmc/articles/PMC4106888/ /pubmed/25050554 http://dx.doi.org/10.1371/journal.pone.0103089 Text en © 2014 Seo et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Seo, Hyungseok
Jang, Dong-Min
Yi, Jung-Min
Min, Hong-Gi
Hwang, Jai-Hyun
The Accuracy of the New Landmark Using Respiratory Jugular Venodilation and Direct Palpation in Right Internal Jugular Vein Access
title The Accuracy of the New Landmark Using Respiratory Jugular Venodilation and Direct Palpation in Right Internal Jugular Vein Access
title_full The Accuracy of the New Landmark Using Respiratory Jugular Venodilation and Direct Palpation in Right Internal Jugular Vein Access
title_fullStr The Accuracy of the New Landmark Using Respiratory Jugular Venodilation and Direct Palpation in Right Internal Jugular Vein Access
title_full_unstemmed The Accuracy of the New Landmark Using Respiratory Jugular Venodilation and Direct Palpation in Right Internal Jugular Vein Access
title_short The Accuracy of the New Landmark Using Respiratory Jugular Venodilation and Direct Palpation in Right Internal Jugular Vein Access
title_sort accuracy of the new landmark using respiratory jugular venodilation and direct palpation in right internal jugular vein access
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4106888/
https://www.ncbi.nlm.nih.gov/pubmed/25050554
http://dx.doi.org/10.1371/journal.pone.0103089
work_keys_str_mv AT seohyungseok theaccuracyofthenewlandmarkusingrespiratoryjugularvenodilationanddirectpalpationinrightinternaljugularveinaccess
AT jangdongmin theaccuracyofthenewlandmarkusingrespiratoryjugularvenodilationanddirectpalpationinrightinternaljugularveinaccess
AT yijungmin theaccuracyofthenewlandmarkusingrespiratoryjugularvenodilationanddirectpalpationinrightinternaljugularveinaccess
AT minhonggi theaccuracyofthenewlandmarkusingrespiratoryjugularvenodilationanddirectpalpationinrightinternaljugularveinaccess
AT hwangjaihyun theaccuracyofthenewlandmarkusingrespiratoryjugularvenodilationanddirectpalpationinrightinternaljugularveinaccess
AT seohyungseok accuracyofthenewlandmarkusingrespiratoryjugularvenodilationanddirectpalpationinrightinternaljugularveinaccess
AT jangdongmin accuracyofthenewlandmarkusingrespiratoryjugularvenodilationanddirectpalpationinrightinternaljugularveinaccess
AT yijungmin accuracyofthenewlandmarkusingrespiratoryjugularvenodilationanddirectpalpationinrightinternaljugularveinaccess
AT minhonggi accuracyofthenewlandmarkusingrespiratoryjugularvenodilationanddirectpalpationinrightinternaljugularveinaccess
AT hwangjaihyun accuracyofthenewlandmarkusingrespiratoryjugularvenodilationanddirectpalpationinrightinternaljugularveinaccess