Cargando…
Evaluation of Optical Quality Parameters and Ocular Aberrations in Multifocal Intraocular Lens Implanted Eyes
PURPOSE: We investigated the correlations between optical quality parameters obtained from the double-pass system and ocular aberrations obtained from the ray-tracing aberrometer in multifocal intraocular lens (IOL) implanted eyes. MATERIALS AND METHODS: Twenty eyes from 20 patients were enrolled in...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Yonsei University College of Medicine
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4108832/ https://www.ncbi.nlm.nih.gov/pubmed/25048505 http://dx.doi.org/10.3349/ymj.2014.55.5.1413 |
_version_ | 1782327792936943616 |
---|---|
author | Lee, Hun Lee, Kwanghyun Ahn, Ji Min Kim, Eung Kweon Sgrignoli, Bradford Kim, Tae-im |
author_facet | Lee, Hun Lee, Kwanghyun Ahn, Ji Min Kim, Eung Kweon Sgrignoli, Bradford Kim, Tae-im |
author_sort | Lee, Hun |
collection | PubMed |
description | PURPOSE: We investigated the correlations between optical quality parameters obtained from the double-pass system and ocular aberrations obtained from the ray-tracing aberrometer in multifocal intraocular lens (IOL) implanted eyes. MATERIALS AND METHODS: Twenty eyes from 20 patients were enrolled in this study. Modulation transfer function cutoff frequency, The Strehl ratio, objective scatter index, and objective pseudo-accommodation obtained from the double-pass system were compared with root mean square (RMS) total aberration, RMS higher-order aberration, and spherical aberration obtained from the ray-tracing aberrometer. Additionally, parameters of the double-pass system and ray-tracing aberrometer were compared with manifested refraction values and subjective visual acuity, respectively. RESULTS: There was no statistically significant correlation between optical quality parameters obtained from the double-pass system and ocular aberrations, except between the Strehl ratio and RMS total aberration (r=-0.566, p=0.018). No significant correlations were found between the parameters of both devices, and manifested refraction values or subjective visual acuity. CONCLUSION: Optical quality parameters, especially the Strehl ratio, in multifocal IOL implanted eyes were affected by RMS total aberration. Further studies based on accurate measurements of ocular aberrations and additional optical quality parameters are needed to delineate relationships between optical quality parameters and ocular aberrations in multifocal IOL implanted eyes. |
format | Online Article Text |
id | pubmed-4108832 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Yonsei University College of Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-41088322014-09-01 Evaluation of Optical Quality Parameters and Ocular Aberrations in Multifocal Intraocular Lens Implanted Eyes Lee, Hun Lee, Kwanghyun Ahn, Ji Min Kim, Eung Kweon Sgrignoli, Bradford Kim, Tae-im Yonsei Med J Original Article PURPOSE: We investigated the correlations between optical quality parameters obtained from the double-pass system and ocular aberrations obtained from the ray-tracing aberrometer in multifocal intraocular lens (IOL) implanted eyes. MATERIALS AND METHODS: Twenty eyes from 20 patients were enrolled in this study. Modulation transfer function cutoff frequency, The Strehl ratio, objective scatter index, and objective pseudo-accommodation obtained from the double-pass system were compared with root mean square (RMS) total aberration, RMS higher-order aberration, and spherical aberration obtained from the ray-tracing aberrometer. Additionally, parameters of the double-pass system and ray-tracing aberrometer were compared with manifested refraction values and subjective visual acuity, respectively. RESULTS: There was no statistically significant correlation between optical quality parameters obtained from the double-pass system and ocular aberrations, except between the Strehl ratio and RMS total aberration (r=-0.566, p=0.018). No significant correlations were found between the parameters of both devices, and manifested refraction values or subjective visual acuity. CONCLUSION: Optical quality parameters, especially the Strehl ratio, in multifocal IOL implanted eyes were affected by RMS total aberration. Further studies based on accurate measurements of ocular aberrations and additional optical quality parameters are needed to delineate relationships between optical quality parameters and ocular aberrations in multifocal IOL implanted eyes. Yonsei University College of Medicine 2014-09-01 2014-07-18 /pmc/articles/PMC4108832/ /pubmed/25048505 http://dx.doi.org/10.3349/ymj.2014.55.5.1413 Text en © Copyright: Yonsei University College of Medicine 2014 http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Lee, Hun Lee, Kwanghyun Ahn, Ji Min Kim, Eung Kweon Sgrignoli, Bradford Kim, Tae-im Evaluation of Optical Quality Parameters and Ocular Aberrations in Multifocal Intraocular Lens Implanted Eyes |
title | Evaluation of Optical Quality Parameters and Ocular Aberrations in Multifocal Intraocular Lens Implanted Eyes |
title_full | Evaluation of Optical Quality Parameters and Ocular Aberrations in Multifocal Intraocular Lens Implanted Eyes |
title_fullStr | Evaluation of Optical Quality Parameters and Ocular Aberrations in Multifocal Intraocular Lens Implanted Eyes |
title_full_unstemmed | Evaluation of Optical Quality Parameters and Ocular Aberrations in Multifocal Intraocular Lens Implanted Eyes |
title_short | Evaluation of Optical Quality Parameters and Ocular Aberrations in Multifocal Intraocular Lens Implanted Eyes |
title_sort | evaluation of optical quality parameters and ocular aberrations in multifocal intraocular lens implanted eyes |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4108832/ https://www.ncbi.nlm.nih.gov/pubmed/25048505 http://dx.doi.org/10.3349/ymj.2014.55.5.1413 |
work_keys_str_mv | AT leehun evaluationofopticalqualityparametersandocularaberrationsinmultifocalintraocularlensimplantedeyes AT leekwanghyun evaluationofopticalqualityparametersandocularaberrationsinmultifocalintraocularlensimplantedeyes AT ahnjimin evaluationofopticalqualityparametersandocularaberrationsinmultifocalintraocularlensimplantedeyes AT kimeungkweon evaluationofopticalqualityparametersandocularaberrationsinmultifocalintraocularlensimplantedeyes AT sgrignolibradford evaluationofopticalqualityparametersandocularaberrationsinmultifocalintraocularlensimplantedeyes AT kimtaeim evaluationofopticalqualityparametersandocularaberrationsinmultifocalintraocularlensimplantedeyes |