Evaluation of Optical Quality Parameters and Ocular Aberrations in Multifocal Intraocular Lens Implanted Eyes

PURPOSE: We investigated the correlations between optical quality parameters obtained from the double-pass system and ocular aberrations obtained from the ray-tracing aberrometer in multifocal intraocular lens (IOL) implanted eyes. MATERIALS AND METHODS: Twenty eyes from 20 patients were enrolled in...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Hun, Lee, Kwanghyun, Ahn, Ji Min, Kim, Eung Kweon, Sgrignoli, Bradford, Kim, Tae-im
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Yonsei University College of Medicine 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4108832/
https://www.ncbi.nlm.nih.gov/pubmed/25048505
http://dx.doi.org/10.3349/ymj.2014.55.5.1413
_version_ 1782327792936943616
author Lee, Hun
Lee, Kwanghyun
Ahn, Ji Min
Kim, Eung Kweon
Sgrignoli, Bradford
Kim, Tae-im
author_facet Lee, Hun
Lee, Kwanghyun
Ahn, Ji Min
Kim, Eung Kweon
Sgrignoli, Bradford
Kim, Tae-im
author_sort Lee, Hun
collection PubMed
description PURPOSE: We investigated the correlations between optical quality parameters obtained from the double-pass system and ocular aberrations obtained from the ray-tracing aberrometer in multifocal intraocular lens (IOL) implanted eyes. MATERIALS AND METHODS: Twenty eyes from 20 patients were enrolled in this study. Modulation transfer function cutoff frequency, The Strehl ratio, objective scatter index, and objective pseudo-accommodation obtained from the double-pass system were compared with root mean square (RMS) total aberration, RMS higher-order aberration, and spherical aberration obtained from the ray-tracing aberrometer. Additionally, parameters of the double-pass system and ray-tracing aberrometer were compared with manifested refraction values and subjective visual acuity, respectively. RESULTS: There was no statistically significant correlation between optical quality parameters obtained from the double-pass system and ocular aberrations, except between the Strehl ratio and RMS total aberration (r=-0.566, p=0.018). No significant correlations were found between the parameters of both devices, and manifested refraction values or subjective visual acuity. CONCLUSION: Optical quality parameters, especially the Strehl ratio, in multifocal IOL implanted eyes were affected by RMS total aberration. Further studies based on accurate measurements of ocular aberrations and additional optical quality parameters are needed to delineate relationships between optical quality parameters and ocular aberrations in multifocal IOL implanted eyes.
format Online
Article
Text
id pubmed-4108832
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Yonsei University College of Medicine
record_format MEDLINE/PubMed
spelling pubmed-41088322014-09-01 Evaluation of Optical Quality Parameters and Ocular Aberrations in Multifocal Intraocular Lens Implanted Eyes Lee, Hun Lee, Kwanghyun Ahn, Ji Min Kim, Eung Kweon Sgrignoli, Bradford Kim, Tae-im Yonsei Med J Original Article PURPOSE: We investigated the correlations between optical quality parameters obtained from the double-pass system and ocular aberrations obtained from the ray-tracing aberrometer in multifocal intraocular lens (IOL) implanted eyes. MATERIALS AND METHODS: Twenty eyes from 20 patients were enrolled in this study. Modulation transfer function cutoff frequency, The Strehl ratio, objective scatter index, and objective pseudo-accommodation obtained from the double-pass system were compared with root mean square (RMS) total aberration, RMS higher-order aberration, and spherical aberration obtained from the ray-tracing aberrometer. Additionally, parameters of the double-pass system and ray-tracing aberrometer were compared with manifested refraction values and subjective visual acuity, respectively. RESULTS: There was no statistically significant correlation between optical quality parameters obtained from the double-pass system and ocular aberrations, except between the Strehl ratio and RMS total aberration (r=-0.566, p=0.018). No significant correlations were found between the parameters of both devices, and manifested refraction values or subjective visual acuity. CONCLUSION: Optical quality parameters, especially the Strehl ratio, in multifocal IOL implanted eyes were affected by RMS total aberration. Further studies based on accurate measurements of ocular aberrations and additional optical quality parameters are needed to delineate relationships between optical quality parameters and ocular aberrations in multifocal IOL implanted eyes. Yonsei University College of Medicine 2014-09-01 2014-07-18 /pmc/articles/PMC4108832/ /pubmed/25048505 http://dx.doi.org/10.3349/ymj.2014.55.5.1413 Text en © Copyright: Yonsei University College of Medicine 2014 http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lee, Hun
Lee, Kwanghyun
Ahn, Ji Min
Kim, Eung Kweon
Sgrignoli, Bradford
Kim, Tae-im
Evaluation of Optical Quality Parameters and Ocular Aberrations in Multifocal Intraocular Lens Implanted Eyes
title Evaluation of Optical Quality Parameters and Ocular Aberrations in Multifocal Intraocular Lens Implanted Eyes
title_full Evaluation of Optical Quality Parameters and Ocular Aberrations in Multifocal Intraocular Lens Implanted Eyes
title_fullStr Evaluation of Optical Quality Parameters and Ocular Aberrations in Multifocal Intraocular Lens Implanted Eyes
title_full_unstemmed Evaluation of Optical Quality Parameters and Ocular Aberrations in Multifocal Intraocular Lens Implanted Eyes
title_short Evaluation of Optical Quality Parameters and Ocular Aberrations in Multifocal Intraocular Lens Implanted Eyes
title_sort evaluation of optical quality parameters and ocular aberrations in multifocal intraocular lens implanted eyes
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4108832/
https://www.ncbi.nlm.nih.gov/pubmed/25048505
http://dx.doi.org/10.3349/ymj.2014.55.5.1413
work_keys_str_mv AT leehun evaluationofopticalqualityparametersandocularaberrationsinmultifocalintraocularlensimplantedeyes
AT leekwanghyun evaluationofopticalqualityparametersandocularaberrationsinmultifocalintraocularlensimplantedeyes
AT ahnjimin evaluationofopticalqualityparametersandocularaberrationsinmultifocalintraocularlensimplantedeyes
AT kimeungkweon evaluationofopticalqualityparametersandocularaberrationsinmultifocalintraocularlensimplantedeyes
AT sgrignolibradford evaluationofopticalqualityparametersandocularaberrationsinmultifocalintraocularlensimplantedeyes
AT kimtaeim evaluationofopticalqualityparametersandocularaberrationsinmultifocalintraocularlensimplantedeyes