Cargando…
Motion Correction of Whole-Body PET Data with a Joint PET-MRI Registration Functional
Respiratory motion is known to degrade image quality in PET imaging. The necessary acquisition time of several minutes per bed position will inevitably lead to a blurring effect due to organ motion. A lot of research has been done with regards to motion correction of PET data. As full-body PET-MRI b...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4108932/ https://www.ncbi.nlm.nih.gov/pubmed/25077815 http://dx.doi.org/10.1186/1475-925X-13-S1-S2 |
_version_ | 1782327812983619584 |
---|---|
author | Fieseler, Michael Gigengack, Fabian Jiang, Xiaoyi Schäfers, Klaus P |
author_facet | Fieseler, Michael Gigengack, Fabian Jiang, Xiaoyi Schäfers, Klaus P |
author_sort | Fieseler, Michael |
collection | PubMed |
description | Respiratory motion is known to degrade image quality in PET imaging. The necessary acquisition time of several minutes per bed position will inevitably lead to a blurring effect due to organ motion. A lot of research has been done with regards to motion correction of PET data. As full-body PET-MRI became available recently, the anatomical data provided by MRI is a promising source of motion information. Current PET-MRI-based motion correction approaches, however, do not take into account the available information provided by PET data. PET data, though, may add valuable additional information to increase motion estimation robustness and precision. In this work we propose a registration functional that is capable of performing motion detection in gated data of two modalities simultaneously. Evaluation is performed using phantom data. We demonstrate that performing a joint registration of both modalities does improve registration accuracy and PET image quality. |
format | Online Article Text |
id | pubmed-4108932 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-41089322014-08-04 Motion Correction of Whole-Body PET Data with a Joint PET-MRI Registration Functional Fieseler, Michael Gigengack, Fabian Jiang, Xiaoyi Schäfers, Klaus P Biomed Eng Online Research Respiratory motion is known to degrade image quality in PET imaging. The necessary acquisition time of several minutes per bed position will inevitably lead to a blurring effect due to organ motion. A lot of research has been done with regards to motion correction of PET data. As full-body PET-MRI became available recently, the anatomical data provided by MRI is a promising source of motion information. Current PET-MRI-based motion correction approaches, however, do not take into account the available information provided by PET data. PET data, though, may add valuable additional information to increase motion estimation robustness and precision. In this work we propose a registration functional that is capable of performing motion detection in gated data of two modalities simultaneously. Evaluation is performed using phantom data. We demonstrate that performing a joint registration of both modalities does improve registration accuracy and PET image quality. BioMed Central 2014-02-28 /pmc/articles/PMC4108932/ /pubmed/25077815 http://dx.doi.org/10.1186/1475-925X-13-S1-S2 Text en Copyright © 2014 Fieseler et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Fieseler, Michael Gigengack, Fabian Jiang, Xiaoyi Schäfers, Klaus P Motion Correction of Whole-Body PET Data with a Joint PET-MRI Registration Functional |
title | Motion Correction of Whole-Body PET Data with a Joint PET-MRI Registration Functional |
title_full | Motion Correction of Whole-Body PET Data with a Joint PET-MRI Registration Functional |
title_fullStr | Motion Correction of Whole-Body PET Data with a Joint PET-MRI Registration Functional |
title_full_unstemmed | Motion Correction of Whole-Body PET Data with a Joint PET-MRI Registration Functional |
title_short | Motion Correction of Whole-Body PET Data with a Joint PET-MRI Registration Functional |
title_sort | motion correction of whole-body pet data with a joint pet-mri registration functional |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4108932/ https://www.ncbi.nlm.nih.gov/pubmed/25077815 http://dx.doi.org/10.1186/1475-925X-13-S1-S2 |
work_keys_str_mv | AT fieselermichael motioncorrectionofwholebodypetdatawithajointpetmriregistrationfunctional AT gigengackfabian motioncorrectionofwholebodypetdatawithajointpetmriregistrationfunctional AT jiangxiaoyi motioncorrectionofwholebodypetdatawithajointpetmriregistrationfunctional AT schafersklausp motioncorrectionofwholebodypetdatawithajointpetmriregistrationfunctional |