Cargando…

Reliability of a rapid hematology stain for sputum cytology

OBJECTIVE: To determine the reliability of a rapid hematology stain for the cytological analysis of induced sputum samples. METHODS: This was a cross-sectional study comparing the standard technique (May-Grünwald-Giemsa stain) with a rapid hematology stain (Diff-Quik). Of the 50 subjects included in...

Descripción completa

Detalles Bibliográficos
Autores principales: Gonçalves, Jéssica, Pizzichini, Emilio, Pizzichini, Marcia Margaret Menezes, Steidle, Leila John Marques, Rocha, Cristiane Cinara, Ferreira, Samira Cardoso, Zimmermann, Célia Tânia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Sociedade Brasileira de Pneumologia e Tisiologia 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4109197/
https://www.ncbi.nlm.nih.gov/pubmed/25029648
http://dx.doi.org/10.1590/S1806-37132014000300008
Descripción
Sumario:OBJECTIVE: To determine the reliability of a rapid hematology stain for the cytological analysis of induced sputum samples. METHODS: This was a cross-sectional study comparing the standard technique (May-Grünwald-Giemsa stain) with a rapid hematology stain (Diff-Quik). Of the 50 subjects included in the study, 21 had asthma, 19 had COPD, and 10 were healthy (controls). From the induced sputum samples collected, we prepared four slides: two were stained with May-Grünwald-Giemsa, and two were stained with Diff-Quik. The slides were read independently by two trained researchers blinded to the identification of the slides. The reliability for cell counting using the two techniques was evaluated by determining the intraclass correlation coefficients (ICCs) for intraobserver and interobserver agreement. Agreement in the identification of neutrophilic and eosinophilic sputum between the observers and between the stains was evaluated with kappa statistics. RESULTS: In our comparison of the two staining techniques, the ICCs indicated almost perfect interobserver agreement for neutrophil, eosinophil, and macrophage counts (ICC: 0.98-1.00), as well as substantial agreement for lymphocyte counts (ICC: 0.76-0.83). Intraobserver agreement was almost perfect for neutrophil, eosinophil, and macrophage counts (ICC: 0.96-0.99), whereas it was moderate to substantial for lymphocyte counts (ICC = 0.65 and 0.75 for the two observers, respectively). Interobserver agreement for the identification of eosinophilic and neutrophilic sputum using the two techniques ranged from substantial to almost perfect (kappa range: 0.91-1.00). CONCLUSIONS: The use of Diff-Quik can be considered a reliable alternative for the processing of sputum samples.