Cargando…

The Use of Screen-Printed Electrodes in a Proof of Concept Electrochemical Estimation of Homocysteine and Glutathione in the Presence of Cysteine Using Catechol

Screen printed electrodes were employed in a proof of concept determination of homocysteine and glutathione using electrochemically oxidized catechol via a 1,4-Michael addition reaction in the absence and presence of cysteine, and each other. Using cyclic voltammetry, the Michael reaction introduces...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Patricia T., Lowinsohn, Denise, Compton, Richard G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4118355/
https://www.ncbi.nlm.nih.gov/pubmed/24926695
http://dx.doi.org/10.3390/s140610395
_version_ 1782328831311347712
author Lee, Patricia T.
Lowinsohn, Denise
Compton, Richard G.
author_facet Lee, Patricia T.
Lowinsohn, Denise
Compton, Richard G.
author_sort Lee, Patricia T.
collection PubMed
description Screen printed electrodes were employed in a proof of concept determination of homocysteine and glutathione using electrochemically oxidized catechol via a 1,4-Michael addition reaction in the absence and presence of cysteine, and each other. Using cyclic voltammetry, the Michael reaction introduces a new adduct peak which is analytically useful in detecting thiols. The proposed procedure relies on the different rates of reaction of glutathione and homocysteine with oxidized catechol so that at fast voltage scan rates only homocysteine is detected in cyclic voltammetry. At slower scan rates, both glutathione and homocysteine are detected. The combination of the two sets of data provides quantification for homocysteine and glutathione. The presence of cysteine is shown not to interfere provided sufficient high concentrations of catechol are used. Calibration curves were determined for each homocysteine and glutathione detection; where the sensitivities are 0.019 μA·μM(−1) and 0.0019 μA·μM(−1) and limit of detections are ca. 1.2 μM and 0.11 μM for homocysteine and glutathione, respectively, within the linear range. This work presents results with potential and beneficial use in re-useable and/or disposable point-of-use sensors for biological and medical applications.
format Online
Article
Text
id pubmed-4118355
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-41183552014-08-01 The Use of Screen-Printed Electrodes in a Proof of Concept Electrochemical Estimation of Homocysteine and Glutathione in the Presence of Cysteine Using Catechol Lee, Patricia T. Lowinsohn, Denise Compton, Richard G. Sensors (Basel) Article Screen printed electrodes were employed in a proof of concept determination of homocysteine and glutathione using electrochemically oxidized catechol via a 1,4-Michael addition reaction in the absence and presence of cysteine, and each other. Using cyclic voltammetry, the Michael reaction introduces a new adduct peak which is analytically useful in detecting thiols. The proposed procedure relies on the different rates of reaction of glutathione and homocysteine with oxidized catechol so that at fast voltage scan rates only homocysteine is detected in cyclic voltammetry. At slower scan rates, both glutathione and homocysteine are detected. The combination of the two sets of data provides quantification for homocysteine and glutathione. The presence of cysteine is shown not to interfere provided sufficient high concentrations of catechol are used. Calibration curves were determined for each homocysteine and glutathione detection; where the sensitivities are 0.019 μA·μM(−1) and 0.0019 μA·μM(−1) and limit of detections are ca. 1.2 μM and 0.11 μM for homocysteine and glutathione, respectively, within the linear range. This work presents results with potential and beneficial use in re-useable and/or disposable point-of-use sensors for biological and medical applications. MDPI 2014-06-12 /pmc/articles/PMC4118355/ /pubmed/24926695 http://dx.doi.org/10.3390/s140610395 Text en © 2014 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Lee, Patricia T.
Lowinsohn, Denise
Compton, Richard G.
The Use of Screen-Printed Electrodes in a Proof of Concept Electrochemical Estimation of Homocysteine and Glutathione in the Presence of Cysteine Using Catechol
title The Use of Screen-Printed Electrodes in a Proof of Concept Electrochemical Estimation of Homocysteine and Glutathione in the Presence of Cysteine Using Catechol
title_full The Use of Screen-Printed Electrodes in a Proof of Concept Electrochemical Estimation of Homocysteine and Glutathione in the Presence of Cysteine Using Catechol
title_fullStr The Use of Screen-Printed Electrodes in a Proof of Concept Electrochemical Estimation of Homocysteine and Glutathione in the Presence of Cysteine Using Catechol
title_full_unstemmed The Use of Screen-Printed Electrodes in a Proof of Concept Electrochemical Estimation of Homocysteine and Glutathione in the Presence of Cysteine Using Catechol
title_short The Use of Screen-Printed Electrodes in a Proof of Concept Electrochemical Estimation of Homocysteine and Glutathione in the Presence of Cysteine Using Catechol
title_sort use of screen-printed electrodes in a proof of concept electrochemical estimation of homocysteine and glutathione in the presence of cysteine using catechol
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4118355/
https://www.ncbi.nlm.nih.gov/pubmed/24926695
http://dx.doi.org/10.3390/s140610395
work_keys_str_mv AT leepatriciat theuseofscreenprintedelectrodesinaproofofconceptelectrochemicalestimationofhomocysteineandglutathioneinthepresenceofcysteineusingcatechol
AT lowinsohndenise theuseofscreenprintedelectrodesinaproofofconceptelectrochemicalestimationofhomocysteineandglutathioneinthepresenceofcysteineusingcatechol
AT comptonrichardg theuseofscreenprintedelectrodesinaproofofconceptelectrochemicalestimationofhomocysteineandglutathioneinthepresenceofcysteineusingcatechol
AT leepatriciat useofscreenprintedelectrodesinaproofofconceptelectrochemicalestimationofhomocysteineandglutathioneinthepresenceofcysteineusingcatechol
AT lowinsohndenise useofscreenprintedelectrodesinaproofofconceptelectrochemicalestimationofhomocysteineandglutathioneinthepresenceofcysteineusingcatechol
AT comptonrichardg useofscreenprintedelectrodesinaproofofconceptelectrochemicalestimationofhomocysteineandglutathioneinthepresenceofcysteineusingcatechol