Cementless Fixation of Osteoporotic VCFs Using Titanium Mesh Implants (OsseoFix): Preliminary Results
Introduction. Vertebral compression fractures (VCFs) affect 20% of people over the age of 70 with increasing incidence. Kypho-/vertebroplasty as standard operative procedures are associated with limitations like cement leakage, limited reduction capabilities, and risk for adjacent fractures. To addr...
Autores principales: | Eschler, Anica, Ender, Stephan Albrecht, Ulmar, Benjamin, Herlyn, Philipp, Mittlmeier, Thomas, Gradl, Georg |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4119652/ https://www.ncbi.nlm.nih.gov/pubmed/25110699 http://dx.doi.org/10.1155/2014/853897 |
Ejemplares similares
-
Fracture care using percutaneously applied titanium mesh cages (OsseoFix®) for unstable osteoporotic thoracolumbar burst fractures is able to reduce cement-associated complications—results after 12 months
por: Ender, Stephan Albrecht, et al.
Publicado: (2015) -
Cementless Titanium Mesh Fixation of Osteoporotic Burst Fractures of the Lumbar Spine Leads to Bony Healing: Results of an Experimental Sheep Model
por: Eschler, Anica, et al.
Publicado: (2016) -
Bony Healing of Unstable Thoracolumbar Burst Fractures in the Elderly Using Percutaneously Applied Titanium Mesh Cages and a Transpedicular Fixation System with Expandable Screws
por: Eschler, Anica, et al.
Publicado: (2015) -
Correction: Bony Healing of Unstable Thoracolumbar Burst Fractures in the Elderly Using Percutaneously Applied Titanium Mesh Cages and a Transpedicular Fixation System with Expandable Screws
por: Eschler, Anica, et al.
Publicado: (2015) -
Percutaneous Stabilization System Osseofix® for Treatment of Osteoporotic Vertebral Compression Fractures - Clinical and Radiological Results after 12 Months
por: Ender, Stephan Albrecht, et al.
Publicado: (2013)