Cargando…

Left-Sided Whole Breast Irradiation with Hybrid-IMRT and Helical Tomotherapy Dosimetric Comparison

Purpose. Limited-tomotherapy and hybrid-IMRT treatment techniques were compared for reductions in ipsilateral and contralateral lung, heart, and contralateral breast radiation doses. Methods and Materials. Thirty consecutively treated left-sided early-stage breast cancer patients were scheduled for...

Descripción completa

Detalles Bibliográficos
Autores principales: Shiau, An-Cheng, Hsieh, Chen-Hsi, Tien, Hui-Ju, Yeh, Hsin-Pei, Lin, Chi-Ta, Shueng, Pei-Wei, Wu, Le-Jung
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4121994/
https://www.ncbi.nlm.nih.gov/pubmed/25170514
http://dx.doi.org/10.1155/2014/741326
_version_ 1782329290639015936
author Shiau, An-Cheng
Hsieh, Chen-Hsi
Tien, Hui-Ju
Yeh, Hsin-Pei
Lin, Chi-Ta
Shueng, Pei-Wei
Wu, Le-Jung
author_facet Shiau, An-Cheng
Hsieh, Chen-Hsi
Tien, Hui-Ju
Yeh, Hsin-Pei
Lin, Chi-Ta
Shueng, Pei-Wei
Wu, Le-Jung
author_sort Shiau, An-Cheng
collection PubMed
description Purpose. Limited-tomotherapy and hybrid-IMRT treatment techniques were compared for reductions in ipsilateral and contralateral lung, heart, and contralateral breast radiation doses. Methods and Materials. Thirty consecutively treated left-sided early-stage breast cancer patients were scheduled for lTomo and hIMRT. For the hIMRT plan conventional tangential-field and four-field IMRT plans were combined with different weightings in the prescribed dose. For the lTomo plan a geometrically limited arc was designed for the beamlet entrance. A D (p) of 50.4 Gy in 28 fractions was used for the PTV. The dose coverage, homogeneity index, conformity index of the target, and the dose volumes of critical structures were compared. Results. Both modalities presented similar target coverage. The homogeneity and conformity were improved for lTomo with P < 0.001 and P = 0.006, respectively. In the lTomo plan a concave dose distribution was generated with significant dose reductions in both high and low dose regions for ipsilateral lung and heart (P < 0.001). Conclusions. lTomo plan can have similar dose coverage and better homogeneity and conformity to the target. By properly designing the directionally and completely blocked structure, lTomo plan was developed successfully in reducing doses to the healthy tissues for early-stage left-sided breast cancer radiotherapy.
format Online
Article
Text
id pubmed-4121994
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-41219942014-08-28 Left-Sided Whole Breast Irradiation with Hybrid-IMRT and Helical Tomotherapy Dosimetric Comparison Shiau, An-Cheng Hsieh, Chen-Hsi Tien, Hui-Ju Yeh, Hsin-Pei Lin, Chi-Ta Shueng, Pei-Wei Wu, Le-Jung Biomed Res Int Research Article Purpose. Limited-tomotherapy and hybrid-IMRT treatment techniques were compared for reductions in ipsilateral and contralateral lung, heart, and contralateral breast radiation doses. Methods and Materials. Thirty consecutively treated left-sided early-stage breast cancer patients were scheduled for lTomo and hIMRT. For the hIMRT plan conventional tangential-field and four-field IMRT plans were combined with different weightings in the prescribed dose. For the lTomo plan a geometrically limited arc was designed for the beamlet entrance. A D (p) of 50.4 Gy in 28 fractions was used for the PTV. The dose coverage, homogeneity index, conformity index of the target, and the dose volumes of critical structures were compared. Results. Both modalities presented similar target coverage. The homogeneity and conformity were improved for lTomo with P < 0.001 and P = 0.006, respectively. In the lTomo plan a concave dose distribution was generated with significant dose reductions in both high and low dose regions for ipsilateral lung and heart (P < 0.001). Conclusions. lTomo plan can have similar dose coverage and better homogeneity and conformity to the target. By properly designing the directionally and completely blocked structure, lTomo plan was developed successfully in reducing doses to the healthy tissues for early-stage left-sided breast cancer radiotherapy. Hindawi Publishing Corporation 2014 2014-07-13 /pmc/articles/PMC4121994/ /pubmed/25170514 http://dx.doi.org/10.1155/2014/741326 Text en Copyright © 2014 An-Cheng Shiau et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Shiau, An-Cheng
Hsieh, Chen-Hsi
Tien, Hui-Ju
Yeh, Hsin-Pei
Lin, Chi-Ta
Shueng, Pei-Wei
Wu, Le-Jung
Left-Sided Whole Breast Irradiation with Hybrid-IMRT and Helical Tomotherapy Dosimetric Comparison
title Left-Sided Whole Breast Irradiation with Hybrid-IMRT and Helical Tomotherapy Dosimetric Comparison
title_full Left-Sided Whole Breast Irradiation with Hybrid-IMRT and Helical Tomotherapy Dosimetric Comparison
title_fullStr Left-Sided Whole Breast Irradiation with Hybrid-IMRT and Helical Tomotherapy Dosimetric Comparison
title_full_unstemmed Left-Sided Whole Breast Irradiation with Hybrid-IMRT and Helical Tomotherapy Dosimetric Comparison
title_short Left-Sided Whole Breast Irradiation with Hybrid-IMRT and Helical Tomotherapy Dosimetric Comparison
title_sort left-sided whole breast irradiation with hybrid-imrt and helical tomotherapy dosimetric comparison
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4121994/
https://www.ncbi.nlm.nih.gov/pubmed/25170514
http://dx.doi.org/10.1155/2014/741326
work_keys_str_mv AT shiauancheng leftsidedwholebreastirradiationwithhybridimrtandhelicaltomotherapydosimetriccomparison
AT hsiehchenhsi leftsidedwholebreastirradiationwithhybridimrtandhelicaltomotherapydosimetriccomparison
AT tienhuiju leftsidedwholebreastirradiationwithhybridimrtandhelicaltomotherapydosimetriccomparison
AT yehhsinpei leftsidedwholebreastirradiationwithhybridimrtandhelicaltomotherapydosimetriccomparison
AT linchita leftsidedwholebreastirradiationwithhybridimrtandhelicaltomotherapydosimetriccomparison
AT shuengpeiwei leftsidedwholebreastirradiationwithhybridimrtandhelicaltomotherapydosimetriccomparison
AT wulejung leftsidedwholebreastirradiationwithhybridimrtandhelicaltomotherapydosimetriccomparison