Bi-level CPAP does not change central blood flow in preterm infants with respiratory distress syndrome
BACKGROUND: Current literature provides limited data on the hemodynamic changes that may occur during bi-level continuous positive airway pressure (CPAP) support in preterm infants. However, the application of a positive end-expiratory pressure may be transmitted to the heart and the great vessels r...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4122055/ https://www.ncbi.nlm.nih.gov/pubmed/24952579 http://dx.doi.org/10.1186/1824-7288-40-60 |
_version_ | 1782329300353024000 |
---|---|
author | Aquilano, Giulia Galletti, Silvia Aceti, Arianna Vitali, Francesca Faldella, Giacomo |
author_facet | Aquilano, Giulia Galletti, Silvia Aceti, Arianna Vitali, Francesca Faldella, Giacomo |
author_sort | Aquilano, Giulia |
collection | PubMed |
description | BACKGROUND: Current literature provides limited data on the hemodynamic changes that may occur during bi-level continuous positive airway pressure (CPAP) support in preterm infants. However, the application of a positive end-expiratory pressure may be transmitted to the heart and the great vessels resulting in changes of central blood flow. OBJECTIVE: To assess changes in central blood flow in infants with respiratory distress syndrome (RDS) during bi-level CPAP support. DESIGN: A prospective study was performed in a cohort of 18 Very-Low-Birth-Weight Infants who were put on nasal CPAP support (4–5 cmH(2)O) because they developed RDS within the first 24–72 hours of life. Each subject was switched to bi-level CPAP support (Phigh 8 cmH(2)O, Plow 4–5 cmH(2)O, Thigh 0.5-0.6 seconds, 20 breaths/min) for an hour. An echocardiographic study and a capillary gas analysis were performed before and after the change of respiratory support. RESULTS: No differences between n-CPAP and bi-level CPAP in left ventricular output (LVO, 222.17 ± 81.4 vs 211.4 ± 75.3 ml/kg/min), right ventricular output (RVO, 287.8 ± 96 vs 283.4 ± 87.4 ml/kg/min) and superior vena cava flow (SVC, 135.38 ± 47.8 vs 137.48 ± 46.6 ml/kg/min) were observed. The hemodynamic characteristics of the ductus arteriosus were similar. A significant decrease in pCO(2) levels after bi-level CPAP ventilation was observed; pCO(2) variations did not correlate with modifications of central blood flow (LVO: ρ = 0.11, p = 0,657; RVO: ρ = −0.307, p = 0.216; SVC: ρ = −0.13, p = 0.197). CONCLUSIONS: Central blood flow doesn’t change during bi-level CPAP support, which could become a hemodinamically safe tool for the treatment of RDS in preterm infants. |
format | Online Article Text |
id | pubmed-4122055 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-41220552014-08-06 Bi-level CPAP does not change central blood flow in preterm infants with respiratory distress syndrome Aquilano, Giulia Galletti, Silvia Aceti, Arianna Vitali, Francesca Faldella, Giacomo Ital J Pediatr Research BACKGROUND: Current literature provides limited data on the hemodynamic changes that may occur during bi-level continuous positive airway pressure (CPAP) support in preterm infants. However, the application of a positive end-expiratory pressure may be transmitted to the heart and the great vessels resulting in changes of central blood flow. OBJECTIVE: To assess changes in central blood flow in infants with respiratory distress syndrome (RDS) during bi-level CPAP support. DESIGN: A prospective study was performed in a cohort of 18 Very-Low-Birth-Weight Infants who were put on nasal CPAP support (4–5 cmH(2)O) because they developed RDS within the first 24–72 hours of life. Each subject was switched to bi-level CPAP support (Phigh 8 cmH(2)O, Plow 4–5 cmH(2)O, Thigh 0.5-0.6 seconds, 20 breaths/min) for an hour. An echocardiographic study and a capillary gas analysis were performed before and after the change of respiratory support. RESULTS: No differences between n-CPAP and bi-level CPAP in left ventricular output (LVO, 222.17 ± 81.4 vs 211.4 ± 75.3 ml/kg/min), right ventricular output (RVO, 287.8 ± 96 vs 283.4 ± 87.4 ml/kg/min) and superior vena cava flow (SVC, 135.38 ± 47.8 vs 137.48 ± 46.6 ml/kg/min) were observed. The hemodynamic characteristics of the ductus arteriosus were similar. A significant decrease in pCO(2) levels after bi-level CPAP ventilation was observed; pCO(2) variations did not correlate with modifications of central blood flow (LVO: ρ = 0.11, p = 0,657; RVO: ρ = −0.307, p = 0.216; SVC: ρ = −0.13, p = 0.197). CONCLUSIONS: Central blood flow doesn’t change during bi-level CPAP support, which could become a hemodinamically safe tool for the treatment of RDS in preterm infants. BioMed Central 2014-06-21 /pmc/articles/PMC4122055/ /pubmed/24952579 http://dx.doi.org/10.1186/1824-7288-40-60 Text en Copyright © 2014 Aquilano et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Aquilano, Giulia Galletti, Silvia Aceti, Arianna Vitali, Francesca Faldella, Giacomo Bi-level CPAP does not change central blood flow in preterm infants with respiratory distress syndrome |
title | Bi-level CPAP does not change central blood flow in preterm infants with respiratory distress syndrome |
title_full | Bi-level CPAP does not change central blood flow in preterm infants with respiratory distress syndrome |
title_fullStr | Bi-level CPAP does not change central blood flow in preterm infants with respiratory distress syndrome |
title_full_unstemmed | Bi-level CPAP does not change central blood flow in preterm infants with respiratory distress syndrome |
title_short | Bi-level CPAP does not change central blood flow in preterm infants with respiratory distress syndrome |
title_sort | bi-level cpap does not change central blood flow in preterm infants with respiratory distress syndrome |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4122055/ https://www.ncbi.nlm.nih.gov/pubmed/24952579 http://dx.doi.org/10.1186/1824-7288-40-60 |
work_keys_str_mv | AT aquilanogiulia bilevelcpapdoesnotchangecentralbloodflowinpreterminfantswithrespiratorydistresssyndrome AT gallettisilvia bilevelcpapdoesnotchangecentralbloodflowinpreterminfantswithrespiratorydistresssyndrome AT acetiarianna bilevelcpapdoesnotchangecentralbloodflowinpreterminfantswithrespiratorydistresssyndrome AT vitalifrancesca bilevelcpapdoesnotchangecentralbloodflowinpreterminfantswithrespiratorydistresssyndrome AT faldellagiacomo bilevelcpapdoesnotchangecentralbloodflowinpreterminfantswithrespiratorydistresssyndrome |